LS ELECTRIC

386 products


  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard ABS33c 20A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS33c 20A

    General Product code 0129002000 Product description ABS33c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 63 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 36 kA at 380 V AC 50/60 Hz, IEC 60947-2 28 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 12.75 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-3 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard ABS104c 125A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 125A

    General Product code 0135000900 Product description ABS104c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

Login

Forgot your password?

Don't have an account yet?
Create account