Schneider Electric circuit breaker Easypact EZC250H - TMD - 200 A - 3 poles 3d EZC250H3200

Description

Description

This is a 200A circuit breaker for EasyPact EZC250H. This product can work below rated operational voltage(Ue) 550VAC at 50/60Hz or 250VDC network. The ultimate breaking capacity(Icu) is shown differently, depended on the condition of network, Ics=50%Icu if need to match. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 105mm(width),165mm(height),60mm(Depth).

Specifications

Main
range of product EasyPact
Product or component type Circuit breaker
Device short name Easypact EZC250H
Circuit breaker name Easypact EZC250H
Device application Distribution
Poles description 3P
Protected poles description 3t
Network type AC
DC
Network frequency 50/60 Hz
[In] rated current 200 A at 40 °C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
250 V DC conforming to IEC 60947-2
Breaking capacity code H
Breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
30 kA Icu at 125 V DC 1P conforming to IEC 60947-2
30 kA Icu at 250 V DC 2P conforming to IEC 60947-2
36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
15 kA at 125 V DC conforming to IEC 60947-2
15 kA at 250 V DC conforming to IEC 60947-2
18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 200 A at 50 °C
Protection type Overload protection
Short-circuit protection
Pollution degree 3 conforming to IEC 60664-1
3 conforming to IEC 947-1
Complementary
Control type Toggle
Mounting mode Fixed
mounting support Backplate
Upside connection Front
downside connection Front
Mechanical durability 10000 cycles
Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch 35 mm
local signalling Positive contact indication
Neutral protection setting Without protection
earth-leakage protection Without
height 165 mm
Width 105 mm
Depth 60 mm
Environment
Standards EN/IEC 60947-1
GB/T 14048.2
EN/IEC 60947-2
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -35…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 10.600 cm
Package 1 Width 11.600 cm
Package 1 Length 18.200 cm
Package 1 Weight 1.588 kg
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 13.623 kg
Unit Type of Package 3 P12
Number of Units in Package 3 64
Package 3 Height 50.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm
Package 3 Weight 120.984 kg

Product form

Description This is a 200A circuit breaker for EasyPact EZC250H. This product can work below rated operational voltage(Ue) 550VAC at... Read more

SKU: EZC250H3200

$121.00 Excl. VAT

    • Quick delivery worldwide
    • Satisfied or refunded
    • Secure payments Paypal

      Description

      Description

      This is a 200A circuit breaker for EasyPact EZC250H. This product can work below rated operational voltage(Ue) 550VAC at 50/60Hz or 250VDC network. The ultimate breaking capacity(Icu) is shown differently, depended on the condition of network, Ics=50%Icu if need to match. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 105mm(width),165mm(height),60mm(Depth).

      Specifications

      Main
      range of product EasyPact
      Product or component type Circuit breaker
      Device short name Easypact EZC250H
      Circuit breaker name Easypact EZC250H
      Device application Distribution
      Poles description 3P
      Protected poles description 3t
      Network type AC
      DC
      Network frequency 50/60 Hz
      [In] rated current 200 A at 40 °C
      [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
      [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
      [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2
      250 V DC conforming to IEC 60947-2
      Breaking capacity code H
      Breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
      25 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
      30 kA Icu at 125 V DC 1P conforming to IEC 60947-2
      30 kA Icu at 250 V DC 2P conforming to IEC 60947-2
      36 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2
      36 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2
      85 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2
      85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2
      [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2
      15 kA at 125 V DC conforming to IEC 60947-2
      15 kA at 250 V DC conforming to IEC 60947-2
      18 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2
      18 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
      12.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
      42.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2
      42.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2
      Suitability for isolation Yes conforming to IEC 60947-2
      utilisation category Category A
      Trip unit name TM-D
      Trip unit technology Thermal-magnetic
      Trip unit rating 200 A at 50 °C
      Protection type Overload protection
      Short-circuit protection
      Pollution degree 3 conforming to IEC 60664-1
      3 conforming to IEC 947-1
      Complementary
      Control type Toggle
      Mounting mode Fixed
      mounting support Backplate
      Upside connection Front
      downside connection Front
      Mechanical durability 10000 cycles
      Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
      Connection pitch 35 mm
      local signalling Positive contact indication
      Neutral protection setting Without protection
      earth-leakage protection Without
      height 165 mm
      Width 105 mm
      Depth 60 mm
      Environment
      Standards EN/IEC 60947-1
      GB/T 14048.2
      EN/IEC 60947-2
      IP degree of protection IP20 conforming to IEC 60529
      IK degree of protection IK07 conforming to IEC 62262
      Ambient air temperature for operation -25…70 °C
      Ambient air temperature for storage -35…85 °C
      Packing Units
      Unit Type of Package 1 PCE
      Number of Units in Package 1 1
      Package 1 Height 10.600 cm
      Package 1 Width 11.600 cm
      Package 1 Length 18.200 cm
      Package 1 Weight 1.588 kg
      Unit Type of Package 2 S03
      Number of Units in Package 2 8
      Package 2 Height 30.000 cm
      Package 2 Width 30.000 cm
      Package 2 Length 40.000 cm
      Package 2 Weight 13.623 kg
      Unit Type of Package 3 P12
      Number of Units in Package 3 64
      Package 3 Height 50.000 cm
      Package 3 Width 80.000 cm
      Package 3 Length 120.000 cm
      Package 3 Weight 120.984 kg

      Reviews

      Schneider Electric circuit breaker Easypact EZC250H - TMD - 200 A - 3 poles 3d EZC250H3200