{"product_id":"nv-ckd-2367945","title":"CKD Pilot Operated 2-Port Solenoid Valve Normally Open Multirex","description":"\u003cp\u003e\u003cstrong\u003eCKD A\u003c\/strong\u003e — Pilot Operated 2-Port Solenoid Valve Normally Open Multirex, genuine CKD product.\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis normally open 2-port solenoid valve from the CKD Multirex range opens a flow path when de-energized and closes it when the coil is powered. Pilot operation uses line pressure to move the main diaphragm or piston, allowing large orifices to be handled by a small coil. It is applied to air, water and other compatible fluids in utility lines and process equipment.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNormally open action fails to the flowing state\u003c\/li\u003e\n\u003cli\u003ePilot design handles large orifices with small coils\u003c\/li\u003e\n\u003cli\u003eSuitable for air, water and compatible general fluids\u003c\/li\u003e\n\u003cli\u003eRugged body for utility and process piping\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003ePort Size\u003c\/th\u003e\n\u003cth\u003ePort Size (Rc)\u003c\/th\u003e\n\u003cth\u003eMass (kg)\u003c\/th\u003e\n\u003cth\u003eNo. of Ports\u003c\/th\u003e\n\u003cth\u003eThread Type\u003c\/th\u003e\n\u003cth\u003ePower Supply (V)\u003c\/th\u003e\n\u003cth\u003eOperation Type\u003c\/th\u003e\n\u003cth\u003eClass\u003c\/th\u003e\n\u003cth\u003eFluid Temp. (℃)\u003c\/th\u003e\n\u003cth\u003eOrifice Diameter (Ømm)\u003c\/th\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003cth\u003eOperation Type\u003c\/th\u003e\n\u003cth\u003eExternal Dimensions (mm)\u003c\/th\u003e\n\u003cth\u003eCoil Housing\u003c\/th\u003e\n\u003cth\u003eCross-Sectional Area (㎟)\u003c\/th\u003e\n\u003cth\u003eCompatibility\u003c\/th\u003e\n\u003cth\u003eRated Voltage (V)\u003c\/th\u003e\n\u003cth\u003eOperating Pressure\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-10A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003eRc3\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50.0\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-10A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50.0\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-15A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e90×57×117\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-15A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003eRc1\/2\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e90×57×117\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-20A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003eRc3\/4\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e1.2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e100×65×126\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-20A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e100×65×126\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-25A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003eRc1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-25A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003eRc1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-8A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e40.5\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAD11-8A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003eRc1\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated diaphragm\u003c\/td\u003e\n\u003ctd\u003e-10~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eAir, water, gas, oil, etc.\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e40.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eAir 0.02~1MPa, water 0.02~1MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-10A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e50×50×114\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-10A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e50×50×114\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-15A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e90×57×136\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-15A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-15A-C4A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e90×57×136\u003c\/td\u003e\n\u003ctd\u003eOpen frame type (class H coil) lead wire\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor steam\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-15A-C4A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e90×57×136\u003c\/td\u003e\n\u003ctd\u003eOpen frame type (class H coil) lead wire\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFor steam\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-20A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e100×65×147\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-20A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e100×65×147\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-20A-C4A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e100×65×147\u003c\/td\u003e\n\u003ctd\u003eOpen frame type (class H coil) lead wire\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-20A-C4A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eOpen frame type (class H coil) lead wire\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003ctd\u003eFor steam\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-25A-03A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e110×76×167\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-25A-03A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e110×76×167\u003c\/td\u003e\n\u003ctd\u003eOpen frame type lead wire\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003eFor air\/water\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-25A-C4A-AC100V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eRc\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003eNormally closed type\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e110×76×167\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003eFor steam\u003c\/td\u003e\n\u003ctd\u003eAC100\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAP11-25A-C4A-AC200V\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated piston\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePilot operated type\u003c\/td\u003e\n\u003ctd\u003e110×76×167\u003c\/td\u003e\n\u003ctd\u003eOpen frame type (class H coil) lead wire\u003c\/td\u003e\n\u003ctd\u003e231\u003c\/td\u003e\n\u003ctd\u003eFor steam\u003c\/td\u003e\n\u003ctd\u003eAC200\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eHow to Order\u003c\/h3\u003e\u003cp\u003eConfirm fluid, port size, orifice diameter, operating pressure range and coil voltage. Please confirm the full part number and options against the CKD catalog; contact us if you need help identifying the right model.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eProduct image is representative of the CKD series; appearance varies by size and model.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eAbout CKD\u003c\/h3\u003e\u003cp\u003eCKD Corporation is a Japanese manufacturer of pneumatic and fluid control components, including solenoid valves, process valves, air cylinders, air preparation units (FRL), fittings and flow control devices.\u003c\/p\u003e\u003ch3\u003eOrdering \u0026amp; Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine CKD product sourced through Korean distribution\u003c\/li\u003e\n\u003cli\u003eShips worldwide from South Korea by FedEx International Priority Express\u003c\/li\u003e\n\u003cli\u003eLead time varies by model; please inquire for exact delivery\u003c\/li\u003e\n\u003cli\u003eImport duties and taxes are payable by the recipient\u003c\/li\u003e\n\u003cli\u003eBulk and trade pricing available on request\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CKD","offers":[{"title":"AD11-10A-03A-AC100V","offer_id":50859437490395,"sku":"AD11-10A-03A-AC100V","price":82.38,"currency_code":"USD","in_stock":true},{"title":"AD11-10A-03A-AC200V","offer_id":50859437523163,"sku":"AD11-10A-03A-AC200V","price":82.38,"currency_code":"USD","in_stock":true},{"title":"AD11-15A-03A-AC100V","offer_id":50859437555931,"sku":"AD11-15A-03A-AC100V","price":116.3,"currency_code":"USD","in_stock":true},{"title":"AD11-15A-03A-AC200V","offer_id":50859437588699,"sku":"AD11-15A-03A-AC200V","price":126.8,"currency_code":"USD","in_stock":true},{"title":"AD11-20A-03A-AC100V","offer_id":50859437621467,"sku":"AD11-20A-03A-AC100V","price":138.11,"currency_code":"USD","in_stock":true},{"title":"AD11-20A-03A-AC200V","offer_id":50859437654235,"sku":"AD11-20A-03A-AC200V","price":136.49,"currency_code":"USD","in_stock":true},{"title":"AD11-25A-03A-AC100V","offer_id":50859437687003,"sku":"AD11-25A-03A-AC100V","price":151.03,"currency_code":"USD","in_stock":true},{"title":"AD11-25A-03A-AC200V","offer_id":50859437719771,"sku":"AD11-25A-03A-AC200V","price":151.03,"currency_code":"USD","in_stock":true},{"title":"AD11-8A-03A-AC100V","offer_id":50859437752539,"sku":"AD11-8A-03A-AC100V","price":80.76,"currency_code":"USD","in_stock":true},{"title":"AD11-8A-03A-AC200V","offer_id":50859437785307,"sku":"AD11-8A-03A-AC200V","price":80.76,"currency_code":"USD","in_stock":true},{"title":"AP11-10A-03A-AC100V","offer_id":50859437818075,"sku":"AP11-10A-03A-AC100V","price":107.42,"currency_code":"USD","in_stock":true},{"title":"AP11-10A-03A-AC200V","offer_id":50859437850843,"sku":"AP11-10A-03A-AC200V","price":107.42,"currency_code":"USD","in_stock":true},{"title":"AP11-15A-03A-AC100V","offer_id":50859437883611,"sku":"AP11-15A-03A-AC100V","price":152.65,"currency_code":"USD","in_stock":true},{"title":"AP11-15A-03A-AC200V","offer_id":50859437916379,"sku":"AP11-15A-03A-AC200V","price":152.65,"currency_code":"USD","in_stock":true},{"title":"AP11-15A-C4A-AC100V","offer_id":50859437949147,"sku":"AP11-15A-C4A-AC100V","price":146.99,"currency_code":"USD","in_stock":true},{"title":"AP11-15A-C4A-AC200V","offer_id":50859437981915,"sku":"AP11-15A-C4A-AC200V","price":145.38,"currency_code":"USD","in_stock":true},{"title":"AP11-20A-03A-AC100V","offer_id":50859438014683,"sku":"AP11-20A-03A-AC100V","price":165.57,"currency_code":"USD","in_stock":true},{"title":"AP11-20A-03A-AC200V","offer_id":50859438047451,"sku":"AP11-20A-03A-AC200V","price":165.57,"currency_code":"USD","in_stock":true},{"title":"AP11-20A-C4A-AC100V","offer_id":50859438080219,"sku":"AP11-20A-C4A-AC100V","price":166.38,"currency_code":"USD","in_stock":true},{"title":"AP11-20A-C4A-AC200V","offer_id":50859438112987,"sku":"AP11-20A-C4A-AC200V","price":166.38,"currency_code":"USD","in_stock":true},{"title":"AP11-25A-03A-AC100V","offer_id":50859438145755,"sku":"AP11-25A-03A-AC100V","price":193.84,"currency_code":"USD","in_stock":true},{"title":"AP11-25A-03A-AC200V","offer_id":50859438178523,"sku":"AP11-25A-03A-AC200V","price":193.84,"currency_code":"USD","in_stock":true},{"title":"AP11-25A-C4A-AC100V","offer_id":50859438211291,"sku":"AP11-25A-C4A-AC100V","price":201.11,"currency_code":"USD","in_stock":true},{"title":"AP11-25A-C4A-AC200V","offer_id":50859438244059,"sku":"AP11-25A-C4A-AC200V","price":199.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1052\/8660\/files\/product_img_10136_GlcC_large_d75d8c17-7b2a-48a8-b39d-5776ebf5d7ba.jpg?v=1792490020","url":"https:\/\/wowtoolz.com\/products\/nv-ckd-2367945","provider":"WowToolz","version":"1.0","type":"link"}