{"product_id":"nv-ckd-2367962","title":"CKD Speed Controller Medium Bore Type SC1 Series","description":"\u003cp\u003e\u003cstrong\u003eCKD SC1\u003c\/strong\u003e — Speed Controller Medium Bore Type SC1 Series, genuine CKD product.\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe CKD SC1 is a medium-bore speed controller that meters air flow in one direction while allowing free flow in the other, setting the extension or retraction speed of pneumatic cylinders. A needle adjusts the metered flow and a built-in check valve handles return flow. It is used in line between the valve and cylinder on general automation equipment.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNeedle valve with check valve for one-way metering\u003c\/li\u003e\n\u003cli\u003eMedium bore suits larger cylinder flow rates\u003c\/li\u003e\n\u003cli\u003eIn-line threaded connection\u003c\/li\u003e\n\u003cli\u003eLock nut keeps the adjusted setting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eDim. H (mm)\u003c\/th\u003e\n\u003cth\u003eFluid Temp. (℃)\u003c\/th\u003e\n\u003cth\u003eProof Pressure (MPa)\u003c\/th\u003e\n\u003cth\u003eDim. F (mm)\u003c\/th\u003e\n\u003cth\u003eAmbient Temp. (℃)\u003c\/th\u003e\n\u003cth\u003eCross-Sectional Area (㎟)\u003c\/th\u003e\n\u003cth\u003eNeedle Turns\u003c\/th\u003e\n\u003cth\u003eDim. C (mm)\u003c\/th\u003e\n\u003cth\u003eFlow Rate (L\/min(ANR))\u003c\/th\u003e\n\u003cth\u003eApplicable Cylinder Bore (Ømm)\u003c\/th\u003e\n\u003cth\u003eDim. J (mm)\u003c\/th\u003e\n\u003cth\u003ePort Size (Rc)\u003c\/th\u003e\n\u003cth\u003eDim. D (mm)\u003c\/th\u003e\n\u003cth\u003eFluid\u003c\/th\u003e\n\u003cth\u003eDim. A (mm)\u003c\/th\u003e\n\u003cth\u003eDim. I (Ømm)\u003c\/th\u003e\n\u003cth\u003eDim. g (mm)\u003c\/th\u003e\n\u003cth\u003eDim. B (mm)\u003c\/th\u003e\n\u003cth\u003eMin. Operating Pressure (MPa)\u003c\/th\u003e\n\u003cth\u003eMax. Operating Pressure (MPa)\u003c\/th\u003e\n\u003cth\u003eDim. k (mm)\u003c\/th\u003e\n\u003cth\u003eDim. E (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC1-10\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e0~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003eFree flow: 39, controlled flow: 22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e21\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC1-15\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003eFree flow: 2900, controlled flow: 2400\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1\/2\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC1-6\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e5~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0~60 (no freezing)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20～50\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/8\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eCompressed air\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e67\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSC1-8\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003ctd\u003eFree flow: 930, controlled flow: 870\u003c\/td\u003e\n\u003ctd\u003e32～75\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eHow to Order\u003c\/h3\u003e\u003cp\u003eSelect by port size and confirm meter-out or meter-in orientation for the cylinder circuit. Please confirm the full part number and options against the CKD catalog; contact us if you need help identifying the right model.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eProduct image is representative of the CKD series; appearance varies by size and model.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eAbout CKD\u003c\/h3\u003e\u003cp\u003eCKD Corporation is a Japanese manufacturer of pneumatic and fluid control components, including solenoid valves, process valves, air cylinders, air preparation units (FRL), fittings and flow control devices.\u003c\/p\u003e\u003ch3\u003eOrdering \u0026amp; Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine CKD product sourced through Korean distribution\u003c\/li\u003e\n\u003cli\u003eShips worldwide from South Korea by FedEx International Priority Express\u003c\/li\u003e\n\u003cli\u003eLead time varies by model; please inquire for exact delivery\u003c\/li\u003e\n\u003cli\u003eImport duties and taxes are payable by the recipient\u003c\/li\u003e\n\u003cli\u003eBulk and trade pricing available on request\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CKD","offers":[{"title":"SC1-10","offer_id":50859476648155,"sku":"SC1-10","price":18.57,"currency_code":"USD","in_stock":true},{"title":"SC1-15","offer_id":50859476680923,"sku":"SC1-15","price":18.57,"currency_code":"USD","in_stock":true},{"title":"SC1-6","offer_id":50859476713691,"sku":"SC1-6","price":17.76,"currency_code":"USD","in_stock":true},{"title":"SC1-8","offer_id":50859476746459,"sku":"SC1-8","price":17.76,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1052\/8660\/files\/product_img_1431_xavG_large_0ff9d2d6-652f-489f-bd36-db5623689841.jpg?v=1792490062","url":"https:\/\/wowtoolz.com\/products\/nv-ckd-2367962","provider":"WowToolz","version":"1.0","type":"link"}