{"product_id":"nv-mel-3629993","title":"MITSUBISHI ELECTRIC Filter Pack FR-BFP Series, FR-BFP2","description":"\u003cp\u003e\u003cstrong\u003eMITSUBISHI ELECTRIC FR-BFP2\u003c\/strong\u003e — Filter Pack FR-BFP Series, genuine MITSUBISHI ELECTRIC product.\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe FR-BFP2 series is a filter pack for Mitsubishi Electric inverters that combines a power factor improving DC reactor, a common-mode choke and a capacitive filter in one unit. It reduces harmonics and electrical noise generated by the inverter. It simplifies compliance with harmonic and EMC requirements in panels.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCombines reactor and noise filters in one unit\u003c\/li\u003e\n\u003cli\u003eReduces harmonics and conducted noise\u003c\/li\u003e\n\u003cli\u003eSaves panel space versus separate parts\u003c\/li\u003e\n\u003cli\u003eSized by inverter capacity and voltage\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eCompatible Models\u003c\/th\u003e\n\u003cth\u003eDimensions (mm)\u003c\/th\u003e\n\u003cth\u003eMass (kg)\u003c\/th\u003e\n\u003cth\u003eEnclosure Protection\u003c\/th\u003e\n\u003cth\u003eOutput Current (A)\u003c\/th\u003e\n\u003cth\u003eEnclosure Protection (JEM1030)\u003c\/th\u003e\n\u003cth\u003eRated Output Voltage (V)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-0.4K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×80\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 2.5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-0.75K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e68×218×60\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 4.2\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-1.5K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×80\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 7\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-11K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×320×85\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 45\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-15K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×320×85\u003c\/td\u003e\n\u003ctd\u003e7.0\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 58\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-2.2K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e68×218×60\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 10\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-3.7K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e170×188×65\u003c\/td\u003e\n\u003ctd\u003e2.8\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 16.5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-5.5K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×210×75\u003c\/td\u003e\n\u003ctd\u003e3.8\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 23.8\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-7.5K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×210×75\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 31.8\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H0.4K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×55\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 1.2\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H0.75K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×55\u003c\/td\u003e\n\u003ctd\u003e1.7\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 2.2\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H1.5K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×80\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 3.7\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H11K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×320×85\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 23\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H15K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×320×85\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 29.5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H2.2K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×80\u003c\/td\u003e\n\u003ctd\u003e2.3\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H3.7K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e108×188×80\u003c\/td\u003e\n\u003ctd\u003e2.6\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 8.1\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H5.5K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×210×75\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 12\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFR-BFP2-H7.5K\u003c\/td\u003e\n\u003ctd\u003eFREQROL\u003c\/td\u003e\n\u003ctd\u003e220×210×75\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e(Allowable inverter) 16.3\u003c\/td\u003e\n\u003ctd\u003eOpen type IP00\u003c\/td\u003e\n\u003ctd\u003e3-phase 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eHow to Order\u003c\/h3\u003e\u003cp\u003eSelect by inverter capacity and voltage class. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.\u003c\/p\u003e\u003ch3\u003eAbout MITSUBISHI ELECTRIC\u003c\/h3\u003e\u003cp\u003eMitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.\u003c\/p\u003e\u003ch3\u003eOrdering \u0026amp; Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine MITSUBISHI ELECTRIC product sourced through Korean distribution\u003c\/li\u003e\n\u003cli\u003eShips worldwide from South Korea by FedEx International Priority Express\u003c\/li\u003e\n\u003cli\u003eLead time varies by model; please inquire for exact delivery\u003c\/li\u003e\n\u003cli\u003eImport duties and taxes are payable by the recipient\u003c\/li\u003e\n\u003cli\u003eBulk and trade pricing available on request\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MITSUBISHI ELECTRIC","offers":[{"title":"FR-BFP2-0.4K","offer_id":50862021607643,"sku":"FR-BFP2-0.4K","price":311.53,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-0.75K","offer_id":50862021640411,"sku":"FR-BFP2-0.75K","price":332.3,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-1.5K","offer_id":50862021673179,"sku":"FR-BFP2-1.5K","price":342.68,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-11K","offer_id":50862021705947,"sku":"FR-BFP2-11K","price":591.91,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-15K","offer_id":50862021738715,"sku":"FR-BFP2-15K","price":623.07,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-2.2K","offer_id":50862021771483,"sku":"FR-BFP2-2.2K","price":353.07,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-3.7K","offer_id":50862021804251,"sku":"FR-BFP2-3.7K","price":373.84,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-5.5K","offer_id":50862021837019,"sku":"FR-BFP2-5.5K","price":519.22,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-7.5K","offer_id":50862021869787,"sku":"FR-BFP2-7.5K","price":560.76,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H0.4K","offer_id":50862021902555,"sku":"FR-BFP2-H0.4K","price":311.53,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H0.75K","offer_id":50862021935323,"sku":"FR-BFP2-H0.75K","price":332.3,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H1.5K","offer_id":50862021968091,"sku":"FR-BFP2-H1.5K","price":342.68,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H11K","offer_id":50862022000859,"sku":"FR-BFP2-H11K","price":591.91,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H15K","offer_id":50862022033627,"sku":"FR-BFP2-H15K","price":623.07,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H2.2K","offer_id":50862022066395,"sku":"FR-BFP2-H2.2K","price":353.07,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H3.7K","offer_id":50862022099163,"sku":"FR-BFP2-H3.7K","price":373.84,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H5.5K","offer_id":50862022131931,"sku":"FR-BFP2-H5.5K","price":519.22,"currency_code":"USD","in_stock":true},{"title":"FR-BFP2-H7.5K","offer_id":50862022164699,"sku":"FR-BFP2-H7.5K","price":560.76,"currency_code":"USD","in_stock":true}],"url":"https:\/\/wowtoolz.com\/products\/nv-mel-3629993","provider":"WowToolz","version":"1.0","type":"link"}