{"product_id":"nv-mel-3630281","title":"MITSUBISHI ELECTRIC Block-Type Remote Unit, NZ2GN2","description":"\u003cp\u003e\u003cstrong\u003eMITSUBISHI ELECTRIC NZ2GN2\u003c\/strong\u003e — Block-Type Remote Unit, genuine MITSUBISHI ELECTRIC product.\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe NZ2GN2B1-32T and NZ2GN2B1-32DT are block-type remote I\/O units from Mitsubishi Electric for the CC-Link IE TSN network, providing transistor outputs (32T) or combined DC inputs and transistor outputs (32DT). Installed close to field devices, they reduce wiring back to the control panel. They are used for distributed I\/O on machines and conveyors.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBlock-type remote I\/O housing\u003c\/li\u003e\n\u003cli\u003eOutput-only or mixed input\/output versions\u003c\/li\u003e\n\u003cli\u003eReduces wiring to the control panel\u003c\/li\u003e\n\u003cli\u003eConnects over CC-Link IE TSN\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eWithstand Voltage\u003c\/th\u003e\n\u003cth\u003eRated Input Voltage (V)\u003c\/th\u003e\n\u003cth\u003eNo. of Outputs\u003c\/th\u003e\n\u003cth\u003eConversion Speed\u003c\/th\u003e\n\u003cth\u003eNo. of Inputs\u003c\/th\u003e\n\u003cth\u003eCommunication Speed\u003c\/th\u003e\n\u003cth\u003eProtection Rating\u003c\/th\u003e\n\u003cth\u003eRated Input Current (A)\u003c\/th\u003e\n\u003cth\u003eRated Load Voltage (V)\u003c\/th\u003e\n\u003cth\u003eInsulation Resistance (MΩ)\u003c\/th\u003e\n\u003cth\u003eInrush Current (A)\u003c\/th\u003e\n\u003cth\u003eLoad Current (mA)\u003c\/th\u003e\n\u003cth\u003eDielectric Strength (V\/1 min)\u003c\/th\u003e\n\u003cth\u003eInput Resistance (kΩ)\u003c\/th\u003e\n\u003cth\u003eVoltage Drop (V)\u003c\/th\u003e\n\u003cth\u003eLeakage Current (mA)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B-60AD4\u003c\/td\u003e\n\u003ctd\u003eAll power\/communication circuits - all analog inputs AC510V for 1 minute\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e200μs\/channel\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1Gbps、100Mbps\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B-60DA4\u003c\/td\u003e\n\u003ctd\u003eAll power\/communication circuits - all analog inputs AC500V for 1 minute\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNumber of analog outputs: 4 (4 channels) \/ 1 unit\u003c\/td\u003e\n\u003ctd\u003e200μs\/channel\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B1-32D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e0.006 TYP. (at DC24V)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween all DC external terminals and ground AC510\/1\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B1-32DT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e0.006 TYP. (at DC24V)\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 4000\/1 common\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B1-32DTE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e0.006 TYP. (at DC24V)\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 4000\/1 common\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B1-32T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC12\/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 4000\/1 common\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e(Max when ON) DC0.3 (TYP.) 0.5A, DC0.6 (MAX.) 0.5A\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2B1-32TE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC12\/24 (ripple 5% or less) (allowable voltage range DC10.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 5000\/1 common\u003c\/td\u003e\n\u003ctd\u003eBetween all DC external terminals and ground AC510\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen OFF: 0.1 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S-60AD4\u003c\/td\u003e\n\u003ctd\u003eAll power\/communication circuits - all analog inputs AC510V for 1 minute\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e200μs\/channel\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1Gbps、100Mbps\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S-60DA4\u003c\/td\u003e\n\u003ctd\u003eAll power\/communication circuits - all analog inputs AC500V for 1 minute\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eNumber of analog outputs: 4 (4 channels) \/ 1 unit\u003c\/td\u003e\n\u003ctd\u003e200μs\/channel\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S1-32D\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e0.006 TYP. (at DC24V)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eBetween all DC external terminals and ground AC510\/1\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S1-32DT\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e0.006 TYP. (at DC24V)\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 4000\/1 common\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S1-32DTE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e0.006 TYP. (at DC24V)\u003c\/td\u003e\n\u003ctd\u003eDC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 4000\/1 common\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S1-32T\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC12\/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 5000\/1 common\u003c\/td\u003e\n\u003ctd\u003eBetween all DC external terminals and ground AC510\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen OFF: 0.1 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNZ2GN2S1-32TE\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIP2X\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDC12\/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8)\u003c\/td\u003e\n\u003ctd\u003e10 or more with DC500V insulation resistance tester between all DC external terminals and ground\u003c\/td\u003e\n\u003ctd\u003e(Max) current limited by overload protection function\u003c\/td\u003e\n\u003ctd\u003eMax: 500\/1 point, 5000\/1 common\u003c\/td\u003e\n\u003ctd\u003eBetween all DC external terminals and ground AC510\/1\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eWhen OFF: 0.1 or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eHow to Order\u003c\/h3\u003e\u003cp\u003eConfirm the network is CC-Link IE TSN and choose the I\/O configuration and output type. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.\u003c\/p\u003e\u003ch3\u003eAbout MITSUBISHI ELECTRIC\u003c\/h3\u003e\u003cp\u003eMitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.\u003c\/p\u003e\u003ch3\u003eOrdering \u0026amp; Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine MITSUBISHI ELECTRIC product sourced through Korean distribution\u003c\/li\u003e\n\u003cli\u003eShips worldwide from South Korea by FedEx International Priority Express\u003c\/li\u003e\n\u003cli\u003eLead time varies by model; please inquire for exact delivery\u003c\/li\u003e\n\u003cli\u003eImport duties and taxes are payable by the recipient\u003c\/li\u003e\n\u003cli\u003eBulk and trade pricing available on request\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MITSUBISHI ELECTRIC","offers":[{"title":"NZ2GN2B-60AD4","offer_id":50862094418139,"sku":"NZ2GN2B-60AD4","price":820.37,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2B-60DA4","offer_id":50862094450907,"sku":"NZ2GN2B-60DA4","price":934.61,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2B1-32D","offer_id":50862094483675,"sku":"NZ2GN2B1-32D","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2B1-32DT","offer_id":50862094516443,"sku":"NZ2GN2B1-32DT","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2B1-32DTE","offer_id":50862094549211,"sku":"NZ2GN2B1-32DTE","price":591.91,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2B1-32T","offer_id":50862094581979,"sku":"NZ2GN2B1-32T","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2B1-32TE","offer_id":50862094614747,"sku":"NZ2GN2B1-32TE","price":591.91,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S-60AD4","offer_id":50862094647515,"sku":"NZ2GN2S-60AD4","price":820.37,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S-60DA4","offer_id":50862094680283,"sku":"NZ2GN2S-60DA4","price":934.61,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S1-32D","offer_id":50862094713051,"sku":"NZ2GN2S1-32D","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S1-32DT","offer_id":50862094745819,"sku":"NZ2GN2S1-32DT","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S1-32DTE","offer_id":50862094778587,"sku":"NZ2GN2S1-32DTE","price":591.91,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S1-32T","offer_id":50862094811355,"sku":"NZ2GN2S1-32T","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NZ2GN2S1-32TE","offer_id":50862094844123,"sku":"NZ2GN2S1-32TE","price":591.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1052\/8660\/files\/thumbnail-ie-field.jpg?v=1792499117","url":"https:\/\/wowtoolz.com\/products\/nv-mel-3630281","provider":"WowToolz","version":"1.0","type":"link"}