{"product_id":"nv-mel-3630577","title":"MITSUBISHI ELECTRIC Molded Case Circuit Breaker NF-S Series (General Purpose) - NF125-SEV 3P 125A","description":"\u003cp\u003e\u003cstrong\u003eMITSUBISHI ELECTRIC NF\u003c\/strong\u003e — Molded Case Circuit Breaker NF-S Series (General Purpose), genuine MITSUBISHI ELECTRIC product.\u003c\/p\u003e\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe NF-S Series is a general-purpose molded case circuit breaker from Mitsubishi Electric, protecting circuits against overload and short circuit. The NF32-SV is a compact 32AF frame used in distribution boards and control panels. It provides reliable protection with standard breaking capacity. Its frame accepts internal accessories such as auxiliary and alarm switches.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOverload and short-circuit protection\u003c\/li\u003e\n\u003cli\u003eStandard (S) class breaking capacity\u003c\/li\u003e\n\u003cli\u003eCompact 32AF frame\u003c\/li\u003e\n\u003cli\u003eAccessories available for expansion\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eCompatibility\u003c\/th\u003e\n\u003cth\u003eMass (kg)\u003c\/th\u003e\n\u003cth\u003eType\u003c\/th\u003e\n\u003cth\u003eInsulation Voltage (V)\u003c\/th\u003e\n\u003cth\u003eRated Current (A)\u003c\/th\u003e\n\u003cth\u003eConnection Method\u003c\/th\u003e\n\u003cth\u003eEarth Leakage Breaker Specification\u003c\/th\u003e\n\u003cth\u003eDimensions (WxHxD mm)\u003c\/th\u003e\n\u003cth\u003eConnection Method\u003c\/th\u003e\n\u003cth\u003eEMC Standard\u003c\/th\u003e\n\u003cth\u003eRated Impulse Withstand Voltage (kV)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SEV 3P 125A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.7\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEnvironment A or environment B: A\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 100A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 125A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 15A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 20A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 30A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 40A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 50A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 60A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 2P 75A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e60×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 100A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 125A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 15A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 20A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 30A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 40A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 45A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 45A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 50A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 60A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 63A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 63A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 71A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e71\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 75A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 3P 90A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e90\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e90×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 100A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 125A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 15A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 20A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 30A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 40A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 50A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 60A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF125-SV 4P 75A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003eApplication-specific breaker\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e120×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 125A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 125A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 150A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 150A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 175A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 200A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 200A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 3P 225A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e105×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 4P 125A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 4P 150A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 4P 175A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 4P 200A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF250-SV 4P 225A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×165×92\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF32-SV 2P 15A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e50×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF32-SV 2P 5A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.45\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e50×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF32-SV 3P 3A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF32-SV 3P 5A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF32-SV 3P 7.1A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e7.1\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF32-SV 3P 8A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 2P 400A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e4.6\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 3P 250A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 3P 300A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 3P 350A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 3P 400A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e140×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 4P 250A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e185×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 4P 300A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e185×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 4P 350A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e185×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF400-SW 4P 400A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e6.8\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e690\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e185×257×155\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 10A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 12A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 16A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 25A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 32A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 45A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 7.1A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e7.1\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-CV 3P 8A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 2P 15A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e50×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 2P 50A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e50×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 10A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 10A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 10A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 12A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 12A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 15A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 16A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 20A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 25A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 25A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 30A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 32A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 32A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 40A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 40A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 45A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 60A\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003eNo-fuse breaker (general use)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 7.1A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e7.1\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 7.1A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e7.1\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 8A MB\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNF63-SV 3P 8A PR\u003c\/td\u003e\n\u003ctd\u003eInsulated\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003eMotor protection circuit breaker\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003eSurface type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e75×130×90\u003c\/td\u003e\n\u003ctd\u003eWith bar terminal\u003c\/td\u003e\n\u003ctd\u003eEMC environmental condition (environment A or B): not applicable\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eHow to Order\u003c\/h3\u003e\u003cp\u003eSpecify frame, number of poles and rated current. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eProduct image is representative of the MITSUBISHI ELECTRIC series; appearance varies by size and model.\u003c\/em\u003e\u003c\/p\u003e\u003ch3\u003eAbout MITSUBISHI ELECTRIC\u003c\/h3\u003e\u003cp\u003eMitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.\u003c\/p\u003e\u003ch3\u003eOrdering \u0026amp; Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenuine MITSUBISHI ELECTRIC product sourced through Korean distribution\u003c\/li\u003e\n\u003cli\u003eShips worldwide from South Korea by FedEx International Priority Express\u003c\/li\u003e\n\u003cli\u003eLead time varies by model; please inquire for exact delivery\u003c\/li\u003e\n\u003cli\u003eImport duties and taxes are payable by the recipient\u003c\/li\u003e\n\u003cli\u003eBulk and trade pricing available on request\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MITSUBISHI ELECTRIC","offers":[{"title":"NF125-SEV 3P 125A","offer_id":50862211530971,"sku":"NF125-SEV 3P 125A","price":581.53,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 100A","offer_id":50862211563739,"sku":"NF125-SV 2P 100A","price":259.61,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 125A","offer_id":50862211596507,"sku":"NF125-SV 2P 125A","price":373.84,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 15A","offer_id":50862211629275,"sku":"NF125-SV 2P 15A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 20A","offer_id":50862211662043,"sku":"NF125-SV 2P 20A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 30A","offer_id":50862211694811,"sku":"NF125-SV 2P 30A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 40A","offer_id":50862211727579,"sku":"NF125-SV 2P 40A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 50A","offer_id":50862211760347,"sku":"NF125-SV 2P 50A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 60A","offer_id":50862211793115,"sku":"NF125-SV 2P 60A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 2P 75A","offer_id":50862211825883,"sku":"NF125-SV 2P 75A","price":269.99,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 100A MB","offer_id":50862211858651,"sku":"NF125-SV 3P 100A MB","price":332.3,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 125A","offer_id":50862211891419,"sku":"NF125-SV 3P 125A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 15A","offer_id":50862211924187,"sku":"NF125-SV 3P 15A","price":353.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 20A","offer_id":50862211956955,"sku":"NF125-SV 3P 20A","price":353.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 30A","offer_id":50862211989723,"sku":"NF125-SV 3P 30A","price":353.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 40A","offer_id":50862212022491,"sku":"NF125-SV 3P 40A","price":353.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 45A MB","offer_id":50862212055259,"sku":"NF125-SV 3P 45A MB","price":332.3,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 45A PR","offer_id":50862212088027,"sku":"NF125-SV 3P 45A PR","price":363.45,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 50A","offer_id":50862212120795,"sku":"NF125-SV 3P 50A","price":353.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 60A","offer_id":50862212153563,"sku":"NF125-SV 3P 60A","price":332.3,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 63A MB","offer_id":50862212186331,"sku":"NF125-SV 3P 63A MB","price":332.3,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 63A PR","offer_id":50862212219099,"sku":"NF125-SV 3P 63A PR","price":363.45,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 71A PR","offer_id":50862212251867,"sku":"NF125-SV 3P 71A PR","price":363.45,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 75A","offer_id":50862212284635,"sku":"NF125-SV 3P 75A","price":353.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 3P 90A PR","offer_id":50862212317403,"sku":"NF125-SV 3P 90A PR","price":363.45,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 100A","offer_id":50862212350171,"sku":"NF125-SV 4P 100A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 125A","offer_id":50862212382939,"sku":"NF125-SV 4P 125A","price":789.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 15A","offer_id":50862212415707,"sku":"NF125-SV 4P 15A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 20A","offer_id":50862212448475,"sku":"NF125-SV 4P 20A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 30A","offer_id":50862212481243,"sku":"NF125-SV 4P 30A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 40A","offer_id":50862212514011,"sku":"NF125-SV 4P 40A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 50A","offer_id":50862212546779,"sku":"NF125-SV 4P 50A","price":488.07,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 60A","offer_id":50862212579547,"sku":"NF125-SV 4P 60A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF125-SV 4P 75A","offer_id":50862212612315,"sku":"NF125-SV 4P 75A","price":519.22,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 125A","offer_id":50862212645083,"sku":"NF250-SV 3P 125A","price":602.3,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 125A MB","offer_id":50862212677851,"sku":"NF250-SV 3P 125A MB","price":654.22,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 150A","offer_id":50862212710619,"sku":"NF250-SV 3P 150A","price":654.22,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 150A MB","offer_id":50862212743387,"sku":"NF250-SV 3P 150A MB","price":654.22,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 175A","offer_id":50862212776155,"sku":"NF250-SV 3P 175A","price":654.22,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 200A","offer_id":50862212808923,"sku":"NF250-SV 3P 200A","price":654.22,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 200A MB","offer_id":50862212841691,"sku":"NF250-SV 3P 200A MB","price":602.3,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 3P 225A MB","offer_id":50862212874459,"sku":"NF250-SV 3P 225A MB","price":602.3,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 4P 125A","offer_id":50862212907227,"sku":"NF250-SV 4P 125A","price":976.14,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 4P 150A","offer_id":50862212939995,"sku":"NF250-SV 4P 150A","price":976.14,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 4P 175A","offer_id":50862212972763,"sku":"NF250-SV 4P 175A","price":893.07,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 4P 200A","offer_id":50862213005531,"sku":"NF250-SV 4P 200A","price":976.14,"currency_code":"USD","in_stock":true},{"title":"NF250-SV 4P 225A","offer_id":50862213038299,"sku":"NF250-SV 4P 225A","price":976.14,"currency_code":"USD","in_stock":true},{"title":"NF32-SV 2P 15A","offer_id":50862213071067,"sku":"NF32-SV 2P 15A","price":51.91,"currency_code":"USD","in_stock":true},{"title":"NF32-SV 2P 5A","offer_id":50862213103835,"sku":"NF32-SV 2P 5A","price":51.91,"currency_code":"USD","in_stock":true},{"title":"NF32-SV 3P 3A","offer_id":50862213136603,"sku":"NF32-SV 3P 3A","price":75.8,"currency_code":"USD","in_stock":true},{"title":"NF32-SV 3P 5A MB","offer_id":50862213169371,"sku":"NF32-SV 3P 5A MB","price":77.87,"currency_code":"USD","in_stock":true},{"title":"NF32-SV 3P 7.1A MB","offer_id":50862213202139,"sku":"NF32-SV 3P 7.1A MB","price":83.07,"currency_code":"USD","in_stock":true},{"title":"NF32-SV 3P 8A MB","offer_id":50862213234907,"sku":"NF32-SV 3P 8A MB","price":83.07,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 2P 400A","offer_id":50862213267675,"sku":"NF400-SW 2P 400A","price":744.27,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 3P 250A","offer_id":50862213300443,"sku":"NF400-SW 3P 250A","price":902.5,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 3P 300A","offer_id":50862213333211,"sku":"NF400-SW 3P 300A","price":902.5,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 3P 350A","offer_id":50862213365979,"sku":"NF400-SW 3P 350A","price":902.5,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 3P 400A","offer_id":50862213398747,"sku":"NF400-SW 3P 400A","price":902.5,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 4P 250A","offer_id":50862213431515,"sku":"NF400-SW 4P 250A","price":1356.27,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 4P 300A","offer_id":50862213464283,"sku":"NF400-SW 4P 300A","price":1356.27,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 4P 350A","offer_id":50862213497051,"sku":"NF400-SW 4P 350A","price":1356.27,"currency_code":"USD","in_stock":true},{"title":"NF400-SW 4P 400A","offer_id":50862213529819,"sku":"NF400-SW 4P 400A","price":1356.27,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 10A PR","offer_id":50862213562587,"sku":"NF63-CV 3P 10A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 12A PR","offer_id":50862213595355,"sku":"NF63-CV 3P 12A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 16A PR","offer_id":50862213628123,"sku":"NF63-CV 3P 16A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 25A PR","offer_id":50862213660891,"sku":"NF63-CV 3P 25A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 32A PR","offer_id":50862213693659,"sku":"NF63-CV 3P 32A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 45A PR","offer_id":50862213726427,"sku":"NF63-CV 3P 45A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 7.1A PR","offer_id":50862213759195,"sku":"NF63-CV 3P 7.1A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-CV 3P 8A PR","offer_id":50862213791963,"sku":"NF63-CV 3P 8A PR","price":114.22,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 2P 15A","offer_id":50862213824731,"sku":"NF63-SV 2P 15A","price":103.84,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 2P 50A","offer_id":50862213857499,"sku":"NF63-SV 2P 50A","price":103.84,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 10A","offer_id":50862213890267,"sku":"NF63-SV 3P 10A","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 10A MB","offer_id":50862213923035,"sku":"NF63-SV 3P 10A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 10A PR","offer_id":50862213955803,"sku":"NF63-SV 3P 10A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 12A MB","offer_id":50862213988571,"sku":"NF63-SV 3P 12A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 12A PR","offer_id":50862214021339,"sku":"NF63-SV 3P 12A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 15A","offer_id":50862214054107,"sku":"NF63-SV 3P 15A","price":129.8,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 16A PR","offer_id":50862214086875,"sku":"NF63-SV 3P 16A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 20A","offer_id":50862214119643,"sku":"NF63-SV 3P 20A","price":134.99,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 25A MB","offer_id":50862214152411,"sku":"NF63-SV 3P 25A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 25A PR","offer_id":50862214185179,"sku":"NF63-SV 3P 25A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 30A","offer_id":50862214217947,"sku":"NF63-SV 3P 30A","price":129.8,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 32A MB","offer_id":50862214250715,"sku":"NF63-SV 3P 32A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 32A PR","offer_id":50862214283483,"sku":"NF63-SV 3P 32A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 40A","offer_id":50862214316251,"sku":"NF63-SV 3P 40A","price":134.99,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 40A MB","offer_id":50862214349019,"sku":"NF63-SV 3P 40A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 45A PR","offer_id":50862214381787,"sku":"NF63-SV 3P 45A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 60A","offer_id":50862214414555,"sku":"NF63-SV 3P 60A","price":166.14,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 7.1A MB","offer_id":50862214447323,"sku":"NF63-SV 3P 7.1A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 7.1A PR","offer_id":50862214480091,"sku":"NF63-SV 3P 7.1A PR","price":150.57,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 8A MB","offer_id":50862214512859,"sku":"NF63-SV 3P 8A MB","price":145.37,"currency_code":"USD","in_stock":true},{"title":"NF63-SV 3P 8A PR","offer_id":50862214545627,"sku":"NF63-SV 3P 8A PR","price":150.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1052\/8660\/files\/mccb_a0973fc9-b1c8-4f9a-874f-d018d9106ba1.jpg?v=1792497456","url":"https:\/\/wowtoolz.com\/products\/nv-mel-3630577","provider":"WowToolz","version":"1.0","type":"link"}