Model
|
PU-30
|
PU-30S
|
PU-50
|
PU-50S
|
|
Sensing method
|
Through-beam
|
|
Sensing distance
|
30 mm
|
50 mm
|
|
Sensing object
|
Ø2 ㎜ min
(Opaque body)
|
Ø0.6 ㎜ min
(Opaque body)
|
Ø1.5 ㎜ min
(Opaque body)
|
Ø0.4 ㎜ min
(Opaque body)
|
|
Power supply voltage
|
12 - 24 V d.c. ± 10 %
|
|
Current consumption
|
30 ㎃ max
|
|
Control output
|
NPN Voltage output, Load current : 200 ㎃ (30 V d.c.) max, Remaining voltage : 2 V d.c. max
|
|
Output action
|
L.ON/D.ON selected by the power reverse connection
|
|
Response time
|
1 ㎳ max
|
|
Light source (wave length)
|
Infrared LED
|
|
Operation Lamp
|
Operation Indicator : Red LED, Power Indicator : Green LED
|
|
Sensitivity adjustment
|
Fixed
|
By the volume
|
Fixed
|
By the volume
|
|
Protective circuit
|
Output short protective circuit
|
|
Ambient illumination
|
▪Sunlight : 11,000 Lux max ▪Incandescent lamp : 3,000 Lux max
|
|
Ambient temperature
|
operating temperature : -20 ~ 60 ℃ During storage : -25 ~ 70 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
35 ~ 85 % RH (With no condensation)
|
|
Protective structure
|
IP 65 (IEC)
|
|
Insulation resistance
|
More than 20 MΩ (500 V d.c. mega)
|
|
Dielectric strength
|
1,000 V a.c. (50/60 Hz for 1 minute)
|
|
Vibration resistance
|
10 - 55 ㎐ double amplitude 1.5 ㎜, for 2 hours each in X · Y · Z directions
|
|
Shock resistance
|
500 m/s², 3 times each in X · Y · Z directions
|
|
Connection method
|
Cable withdrawal type (number of wires : 3P, outer diameter : Ø4 ㎜, length : 2 m)
|
|
Material
|
Case : ZN, Lens : PC
|
|
Certification
|
 |
|
Weight
|
Approx. 250g (Included the weight of box)
|