LS ELECTRIC
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS203c 100A
General Product code 0137000100 Product description ABS203c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-42 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$158.95
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 250A
General Product code 0138000700 Product description ABS204c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 225A
General Product code 0138000600 Product description ABS204c 225A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 225 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 200A
General Product code 0138000500 Product description ABS204c 200A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 200 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 175A
General Product code 0138000400 Product description ABS204c 175A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 175 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 150A
General Product code 0138000300 Product description ABS204c 150A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 150 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 125A
General Product code 0138000200 Product description ABS204c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS204c 100A
General Product code 0138000100 Product description ABS204c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-43 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.
$183.81
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 350A
General Product code 0164001500 Product description ABS402c 350A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 350 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 300A
General Product code 0164001400 Product description ABS402c 300A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 300 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 250A
General Product code 0164001300 Product description ABS402c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS403c 400A
General Product code 0164002000 Product description ABS403c 400A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 400 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-54 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$271.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS403c 350A
General Product code 0164001900 Product description ABS403c 350A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 350 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-54 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$271.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS403c 300A
General Product code 0164001800 Product description ABS403c 300A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 300 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-54 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$271.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS403c 250A
General Product code 0164001700 Product description ABS403c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-54 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$271.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS404c 400A
General Product code 0164002400 Product description ABS404c 400A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 400 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-55 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$328.02
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS404c 350A
General Product code 0164002300 Product description ABS404c 350A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 350 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-55 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$328.02
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS404c 300A
General Product code 0164002200 Product description ABS404c 300A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 300 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-55 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$328.02
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS404c 250A
General Product code 0164002100 Product description ABS404c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-55 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$328.02
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS802c 800A
General Product code 0166000700 Product description ABS802c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-65 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$622.60
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS802c 700A
General Product code 0166000700 Product description ABS802c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-65 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$622.60
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS802c 630A
General Product code 0166002800 Product description ABS802c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-65 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$622.60
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS802c 500A
General Product code 0166002700 Product description ABS802c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-65 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$622.60
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS803c 800A
General Product code 0166001000 Product description ABS803c 800A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 800 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-66 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$761.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS803c 700A
General Product code 0166000900 Product description ABS803c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-66 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$761.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS803c 630A
General Product code 0166003400 Product description ABS803c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-66 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$761.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS803c 500A
General Product code 0166002900 Product description ABS803c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-66 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$761.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS804c 800A
General Product code 0166001200 Product description ABS804c 800A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 800 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-67 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$887.37
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS804c 700A
General Product code 0166001100 Product description ABS804c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-67 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$887.37
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS804c 630A
General Product code 0166003600 Product description ABS804c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-67 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$887.37
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS804c 500A
General Product code 0166003500 Product description ABS804c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 75 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 45 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 165 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-67 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$887.37
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 100A
General Product code 0136000100 Product description ABS202c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 125A
General Product code 0136000200 Product description ABS202c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 150A
General Product code 0136000300 Product description ABS202c 150A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 150 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 175A
General Product code 0136000400 Product description ABS202c 175A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 175 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 200A
General Product code 0136000500 Product description ABS202c 200A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 200 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 225A
General Product code 0136000600 Product description ABS202c 225A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 225 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202C 250A
General Product code 0136000700 Product description ABS202c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.64
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 250A
General Product code 0164001300 Product description ABS402c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 300A
General Product code 0164001400 Product description ABS402c 300A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 300 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 350A
General Product code 0164001500 Product description ABS402c 350A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 350 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS402c 400A
General Product code 0164001600 Product description ABS402c 400A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 400 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 75 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 65 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 165 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 143 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-53 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 5.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 5.5 kg Quantity (in a box) 1 pcs.
$232.32
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 30A
General Product code 0135000300 Product description ABS104c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$84.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 40A
General Product code 0135000400 Product description ABS104c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$84.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 50A
General Product code 0135000500 Product description ABS104c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$84.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 60A
General Product code 0135000600 Product description ABS104c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$84.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 75A
General Product code 0135000700 Product description ABS104c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$84.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS104c 100A
General Product code 0135000800 Product description ABS104c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-31 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$84.15