Products
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDAW30-12DN-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 120 g (≈ 180 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$110.36
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDAW30-12DP-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 120 g (≈ 180 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$110.36
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW08-2DN-V
Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 150Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 25 g (≈ 50 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$81.19
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW08-2DP-V
Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 150Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 25 g (≈ 50 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$81.19
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW12-3DN-V
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 35 g (≈ 60 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$72.03
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW18-7DN-V
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 55 g (≈ 90 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$81.19
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW18-7DP-V
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 55 g (≈ 90 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$81.19
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW30-12DN-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 120 g (≈ 180 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$91.21
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW30-12DP-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 120 g (≈ 180 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$91.21
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM08-2D-IL2
Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 150Hz Indicator IO-Link mode, SIO mode Unit weight (packaged weight) ≈ 10 g (≈ 35 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303) Industrial proximity sensor for automation systems.
$85.74
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM08-2DN
Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 150Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 10 g (≈ 35 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$85.74
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM08-2DP
Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 150Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 10 g (≈ 35 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$85.74
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM12-3D-IL2
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 80Hz Indicator IO-Link mode, SIO mode Unit weight (packaged weight) ≈ 15 g (≈ 40 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$76.62
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM12-3DN
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 15 g (≈ 40 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$76.62
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM12-3DP
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 15 g (≈ 40 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$76.62
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM18-7D-IL2
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator IO-Link mode, SIO mode Unit weight (packaged weight) ≈ 32 g (≈ 67 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$85.74
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM18-7DN
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 32 g (≈ 67 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$85.74
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM18-7DP
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 32 g (≈ 67 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$85.74
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM30-12D-IL2
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator IO-Link mode, SIO mode Unit weight (packaged weight) ≈ 85 g (≈ 140 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$95.77
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM30-12DN
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 85 g (≈ 140 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$95.77
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM30-12DP
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 85 g (≈ 140 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$95.77
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRAWT12-2DO
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 42 g (≈ 54 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE Industrial proximity sensor for automation systems.
$47.36
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRAWT18-5DO
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE Industrial proximity sensor for automation systems.
$49.23
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRAWT30-10DO
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 122 g (≈ 134 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE Industrial proximity sensor for automation systems.
$57.42
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRDAT12-4DO
Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 450Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72g (≈ 84g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE
$46.42
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRDAT18-7DO
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 20×20×1mm(iron) Response frequency 250Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 122g (≈ 134g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE Industrial proximity sensor for automation systems.
$49.23
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRDAT30-15DO
Installation Flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 221 g (≈ 184 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE Industrial proximity sensor for automation systems.
$55.54
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor AC 2-Wire PRW12-2AO
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 42 g (≈ 54 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 150 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$26.43
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor AC 2-Wire PRW18-8AO
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 66 g (≈ 78 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT Industrial proximity sensor for automation systems.
$25.50
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor AC 2-Wire PRW30-10AO
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 122 g (≈ 134 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT Industrial proximity sensor for automation systems.
$27.37
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor AC 2-Wire PRW30-15AO
Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 122 g (≈ 134 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT Industrial proximity sensor for automation systems.
$27.37
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAT08-1.5DO-V
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 55 g (≈ 80 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$22.81
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAT12-2DO-V
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 83 g (≈ 110 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$86.66
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAT18-5DO-V
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$91.21
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAT30-10DO-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$95.77
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAWT08-1.5DO-IV
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 55 g (≈ 80 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$95.77
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAWT12-2DO-IV
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 83 g (≈ 110 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$91.21
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAWT18-5DO-IV
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$95.77
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAWT30-10DO-IV
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$141.50
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT08-1.5DO-V
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 55 g (≈ 80 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$67.47
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT12-2DO-V
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 83 g (≈ 110 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$57.42
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT18-5DO-V
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$67.47
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT30-10DO-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$76.60
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT08-1.5DO-IV
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 55 g (≈ 80 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$72.03
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT12-2DO-IV
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 83 g (≈ 110 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$61.98
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT18-5DO-IV
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$72.03
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT30-10DO-IV
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$81.15
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT08-2DC
Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55