Products
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 30A
General Product code 0133001200 Product description ABH52c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.
$47.94
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 40A
General Product code 0133001300 Product description ABH52c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.
$47.94
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 50A
General Product code 0133001400 Product description ABH52c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.
$47.94
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 15A
General Product code 0134001000 Product description ABH53c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.
$63.00
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 20A
General Product code 0134001100 Product description ABH53c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.
$63.00
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 30A
General Product code 0134001200 Product description ABH53c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.
$63.00
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 40A
General Product code 0134001300 Product description ABH53c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.
$63.00
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 50A
General Product code 0134001400 Product description ABH53c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.
$63.00
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 15A
General Product code 0135001000 Product description ABH54c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$78.68
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 20A
General Product code 0135001100 Product description ABH54c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$78.68
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 30A
General Product code 0135001200 Product description ABH54c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$78.68
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 40A
General Product code 0135001300 Product description ABH54c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$78.68
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 50A
General Product code 0135001400 Product description ABH54c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.
$78.68
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 100A
General Product code 0130003400 Product description ABN102c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 15A
General Product code 0130002700 Product description ABN102c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 20A
General Product code 0130002800 Product description ABN102c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 30A
General Product code 0130002900 Product description ABN102c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 40A
General Product code 0130003000 Product description ABN102c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 50A
General Product code 0130003100 Product description ABN102c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 60A
General Product code 0130003200 Product description ABN102c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN102c 75A
General Product code 0130003300 Product description ABN102c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-17 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.
$34.15
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 100A
General Product code 0131008400 Product description ABN103c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 15A
General Product code 0131007700 Product description ABN103c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 15A
General Product code 0131007700 Product description ABN103c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 20A
General Product code 0131007800 Product description ABN103c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 30A
General Product code 0131007900 Product description ABN103c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 40A
General Product code 0131008000 Product description ABN103c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 50A
General Product code 0131008100 Product description ABN103c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 60A
General Product code 0131008200 Product description ABN103c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 75A
General Product code 0131008300 Product description ABN103c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.
$49.21
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 100A
General Product code 0132006600 Product description ABN104c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 100A
General Product code 0132006600 Product description ABN104c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 15A
General Product code 0132005900 Product description ABN104c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 15A
General Product code 0132005900 Product description ABN104c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 20A
General Product code 0132006000 Product description ABN104c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 20A
General Product code 0132006000 Product description ABN104c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 30A
General Product code 0132006100 Product description ABN104c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 30A
General Product code 0132006100 Product description ABN104c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 40A
General Product code 0132006200 Product description ABN104c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 40A
General Product code 0132006200 Product description ABN104c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 50A
General Product code 0132006300 Product description ABN104c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 50A
General Product code 0132006300 Product description ABN104c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 60A
General Product code 0132006400 Product description ABN104c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 60A
General Product code 0132006400 Product description ABN104c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 75A
General Product code 0132006500 Product description ABN104c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN104c 75A
General Product code 0132006500 Product description ABN104c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-19 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 100 mm Height 130 mm Depth 60 mm Weight 0.9 kg Packing Width 289 mm Height 567 mm Depth 105 mm Weight 10.4 kg Quantity (in a box) 10 pcs.
$61.48
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN202c 100A
General Product code 0136001500 Product description ABN202c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-38 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.34
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN202c 100A
General Product code 0136001500 Product description ABN202c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-38 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.
$134.34