Autonics Autonics Photoelectric Sensor, Photoelectric Type BYD50-DDT
Sensing type Convergent reflective type Sensing distance 10 to 50mm Sensing target Opaque, Translucent material Response time Operation: Max. 3ms, Return: Max. 100ms Light source Infrared LED Operation mode Light ON Weight Approx. 75g(approx. 38g) Power voltage 12-24VDC ±10%(ripple P-P: max. 10%) Current consumption Max. 35mA Control output NPN open collector Environment_Ambient illumination Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination) Environment_Ambient temperature -20 to 65℃, storage: -25 to 70℃ Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH Protection structure IP64 Connection type Cable type(Ø3.5, 2m) Material Case: PC, sensing part: PC, bracket: SPCC, bolt: SCM, nut: SCM, sleeve: Brass, Ni-plate
$18.36
Autonics Autonics Photoelectric Sensor, Photoelectric Type BYD50-DDT-T
Sensing type Convergent reflective type Sensing distance 10 to 50mm Sensing target Opaque, Translucent material Response time Operation: Max. 3ms, Return: Max. 100ms Light source Infrared LED Timer function Timer Function Operation mode Light ON Weight Approx. 75g(approx. 38g) Power voltage 12-24VDC ±10%(ripple P-P: max. 10%) Current consumption Max. 35mA Control output NPN open collector Environment_Ambient illumination Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination) Environment_Ambient temperature -20 to 65℃, storage: -25 to 70℃ Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH Protection structure IP50 Connection type Cable type(Ø3.5, 2m) Material Case: PC, sensing part: PC, bracket: SPCC, bolt: SCM, nut: SCM, sleeve: Brass, Ni-plate
$21.87
Autonics Autonics Photoelectric Sensor, Photoelectric Type BYD50-DDT-U 12-24VDC GL
Sensing type Convergent reflective type Sensing distance 10 to 50mm Sensing target Opaque, Translucent material Response time Operation: Max. 3ms, Return: Max. 100ms Light source Infrared LED Operation mode Light ON Weight Approx. 75g(approx. 38g) Power voltage 12-24VDC ±10%(ripple P-P: max. 10%) Current consumption Max. 35mA Control output NPN open collector Environment_Ambient illumination Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination) Environment_Ambient temperature -20 to 65℃, storage: -25 to 70℃ Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH Protection structure IP50 Connection type Cable type(Ø3.5, 2m) Material Case: PC, sensing part: PC, bracket: SPCC, bolt: SCM, nut: SCM, sleeve: Brass, Ni-plate
$19.06
Autonics Autonics Photoelectric Sensor, Photoelectric Type BYS500-TDT1,2
Sensing type Through-beam type(side sensing type) Sensing distance 500mm Sensing target Opaque material of min. Ø5mm Response time Max. 1ms Light source Infrared LED(940nm) Operation mode Dark ON Weight ≈ 150 g (≈ 200 g) Power voltage 12-24VDC ±10%(ripple P-P: max. 10%) Current consumption Emitter/Receiver: Max. 30mA Control output NPN open collector Environment_Ambient illumination Sunlight: Max. 11,000lx, Incandescent lamp: Max. 3,000lx (received illumination) Environment_Ambient temperature -10 to 60℃, storage: -25 to 70℃ Environment_Ambient humidity 35 to 85% RH, storage: 35 to 85% RH Protection structure IP50 Connection type Cable type(Ø4, 2m) Material Case: PC, sensing part: PC, bracket: SPCC, bolt: SCM, nut: SCM
$24.33
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT08-1.5DC
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT08-1.5DO
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT18-5DC
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT18-5DO
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR12-2AC
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 150 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR12-2AO
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 150 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR12-4AC
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 150 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR12-4AO
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 150 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$21.87
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR18-5AC
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 118 g (≈ 130 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.11
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR18-5AO
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 118 g (≈ 130 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR18-8AC
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 118 g (≈ 130 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR18-8AO
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 118 g (≈ 130 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-10AC
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-10AO
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-15AC
Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-15AO
Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL18-5AC
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL18-5AO
Industrial proxim Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT ity sensor for automation systems.
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL18-8AC
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL18-8AO
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL30-10AC
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 208 g (≈ 245 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL30-10AO
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 208 g (≈ 245 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL30-15AC
Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 208 g (≈ 245 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL30-15AO
Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 208 g (≈ 245 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire 2m Cable PRT12-4DO
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$16.61
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire 5m Cable PRT12-4DO
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side:
$20.58
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-1.5DC
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-1.5DO
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-2DO
Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT12-2DC
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$17.31
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT12-2DO
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$17.31
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT12-4DC
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$16.61
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-5DC
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$15.44
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-5DO
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$14.85
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-8DC
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$15.44
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-8DO
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$14.85
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-10DO
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$17.54
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-15DC
stallation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$18.23
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-15DO
Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$17.42
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire 2m Cable PR18-8DN
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$14.85
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire 5m Cable PR18-8DN
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side:
$18.71
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire 5m PR08-1.5DN
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$23.27
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR08-1.5DN
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$18.71
Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR08-1.5DN2
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99