Description
SMC SY5120-5YO-01F-Q — SY5000 series 5-port solenoid valve, body ported single unit with Rc 1/8 connections. Piped directly at the valve, so no subplate or manifold base is needed.
Specification — SY5120-5YO-01F-Q
| Series |
SY5000 (5-port solenoid valve) |
| Type |
Body ported, single unit |
| Port size |
Rc 1/8 (01F) |
| Power consumption |
0.1 W (power saving circuit) |
| Manifold bases |
SS5Y3, SS5Y5, SS5Y7, SS5Y9 |
| Product weight |
93 g |
Body ported or base mounted
A body ported valve takes the tubing straight into the valve, which suits a single cylinder sitting on its own somewhere in the machine. A base mounted valve (SY5140) needs a subplate but shares supply and exhaust across a manifold, which is what you want once several valves sit together. Both use the same internals — the choice is about how the air is piped.
Why 0.1 W matters
With the power saving circuit the coil draws a tenth of what an ordinary valve takes, so a bank of valves can run from a small PLC output card and adds almost no heat to the cabinet.
Typical use
Single cylinder control away from the main valve bank — clamps, stoppers and ejectors mounted out on the machine.
Ordering
Order by the full code SY5120-5YO-01F-Q. Coil voltage, electrical entry, port thread and pilot type are all in the suffix — confirm each against the valve being replaced. The base mounted SY5140 covers manifold use.
Supply from Korea
Genuine SMC, stocked and shipped from Gyeonggi-do, Korea, with export packing and commercial documents prepared as standard.