  • LS ELECTRIC Magnetic Contactor MC-40a AC220V 50/60Hz SCREW 1a1b (Metasol) EXP (MC40A-30-11-M7-S-E)

    LS ELECTRIC LS ELECTRIC Magnetic Contactor MC-40a AC220V 50/60Hz SCREW 1a1b (Metasol) EXP (MC40A-30-11-M7-S-E)

    General Product code 1337006900 Product description MC-40a AC220V 50/60Hz SCREW 1a1b (Metasol) EXP (MC40A-30-11-M7-S-E) Main contact 3NO Auxiliary contact 1NO 1NC Control voltage AC220V 50/60Hz Type of terminal Screw Local/Export Export Standards IEC 60947-4-1, IEC 60947-5-1, UL508 Certificates CE, UL, CCC KR, LR, BV, DNV, ABS, NK, RINA Characteristics Number of poles 3P Rated operational voltage [Ue] 1000V Rated insulation voltage [Ui] 1000V Rated withstand voltage [Uimp] 8kV Rated frequency [Hz] 50/60Hz Maximum operating rate in operating cycles per hour(AC3) 50/60Hz Mechanical durability (mil. operations) 50/60Hz Electrical durability (mil. operations) 50/60Hz Rated operational current (AC-1) 60A Power (AC-1) - - - - Current (AC-1) - - - - Motor power (AC-3) 11kW at 200/240V 18.5kW at 380/440V 22kW at 500/550V 22kW at 690V 22kW at 1000V Motor power (AC-4) 5.5kW at 200/240V 11kW at 380/440V Rated operational current (AC-3) 40A at 200/240V 40A at 380/440V 32A at 500/550V 23A at 690V 17A at 690V Rated operational current (AC-4) 25A at 200/240V 24A at 380/440V Rated operational current (DC-3,5) - - - Rated operational current (DC-1) - Type 2 Coordination See the Type 2 Coordination Table in the catalog Motor power (UL/CSA) 3hp at 110~220V for 1 phase motors 7.5hp at 220~240V for 1 phase motors 15hp at 200~208V for 3 phase motors 15hp at 220~240V for 3 phase motors 30hp at 440~480V for 3 phase motors 30hp at 550~600V for 3 phase motors NEMA size 30hp at 550~600V for 3 phase motors Rated Short-time withstand current 700A at 1s 300A at 10s 190A at 30s 120A at 1min 80A at 3min 65A at 10min 60A at =15min Conductor size (AWG) 8~6 Conductor size (mm2) 10~16 The max. number of conductor 10~16 Conductor type Solid, Stranded Conductor charateristic 65/75? Cu-wire only Main terminal size M5 Crimp terminal (mm) M5 Torque (lb-in) M5 Torque (Nm) M5 Torque (kgf.cm) M5 Environment Degree of protection IP20 Ambient air temperature -30? ~ +65? at storage -5? ~ +55? at operation (AC type) Operating altitude 3000m(8900ft) Shock resistance (1/2 sin wave=11ms) 8G at opened 10G at closed Vibration resistance (Conforming to IEC68-2-6) (5~300Hz) 2G at opened 4G at closed Flame resistance V0 at conforming to UL94 960? at conforming to IEC695-2-1 REACH Yes RoHS Yes WEEE Yes Dimensions Weight 0.5kg Size width 57mm / 2.24inch Size height 83mm / 3.27inch Size depth 90mm / 3.54inch Control coil Control voltage AC220V 50/60Hz Control voltage limit [Uc] 85~110% Consumption at 20℃ 90VA at inrush 9VA at holding Heat dissipation 2.7W at holding Operating time 15~30ms at closing 4~19ms at opening Applicable Accessories

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS32c 10A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS32c 10A

    General Product code 0128001800 Product description ABS32c 10A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 10 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 25 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 14 kA at 380 V AC 50/60 Hz, IEC 60947-2 10 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, Reference 5 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 25 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 14 kA at 380 V AC 50/60 Hz, IEC 60947-2 10 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, Reference 5 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 52.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 28 kA at 380 V AC 50/60 Hz, IEC 60947-2 17 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-2 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Magnetic Contactor MC-40a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC40A-30-11-K7-S-E)

    LS ELECTRIC LS ELECTRIC Magnetic Contactor MC-40a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC40A-30-11-K7-S-E)

    General Product code 1337006700 Product description MC-40a AC120V 50/60Hz SCREW 1a1b (Metasol) EXP (MC40A-30-11-K7-S-E) Main contact 3NO Auxiliary contact 1NO 1NC Control voltage AC120V 50/60Hz Type of terminal Screw Local/Export Export Standards IEC 60947-4-1, IEC 60947-5-1, UL508 Certificates CE, UL, CCC KR, LR, BV, DNV, ABS, NK, RINA Characteristics Number of poles 3P Rated operational voltage [Ue] 1000V Rated insulation voltage [Ui] 1000V Rated withstand voltage [Uimp] 8kV Rated frequency [Hz] 50/60Hz Maximum operating rate in operating cycles per hour(AC3) 50/60Hz Mechanical durability (mil. operations) 50/60Hz Electrical durability (mil. operations) 50/60Hz Rated operational current (AC-1) 60A Power (AC-1) - - - - Current (AC-1) - - - - Motor power (AC-3) 11kW at 200/240V 18.5kW at 380/440V 22kW at 500/550V 22kW at 690V 22kW at 1000V Motor power (AC-4) 5.5kW at 200/240V 11kW at 380/440V Rated operational current (AC-3) 40A at 200/240V 40A at 380/440V 32A at 500/550V 23A at 690V 17A at 690V Rated operational current (AC-4) 25A at 200/240V 24A at 380/440V Rated operational current (DC-3,5) - - - Rated operational current (DC-1) - Type 2 Coordination See the Type 2 Coordination Table in the catalog Motor power (UL/CSA) 3hp at 110~220V for 1 phase motors 7.5hp at 220~240V for 1 phase motors 15hp at 200~208V for 3 phase motors 15hp at 220~240V for 3 phase motors 30hp at 440~480V for 3 phase motors 30hp at 550~600V for 3 phase motors NEMA size 30hp at 550~600V for 3 phase motors Rated Short-time withstand current 700A at 1s 300A at 10s 190A at 30s 120A at 1min 80A at 3min 65A at 10min 60A at =15min Conductor size (AWG) 8~6 Conductor size (mm2) 10~16 The max. number of conductor 10~16 Conductor type Solid, Stranded Conductor charateristic 65/75? Cu-wire only Main terminal size M5 Crimp terminal (mm) M5 Torque (lb-in) M5 Torque (Nm) M5 Torque (kgf.cm) M5 Environment Degree of protection IP20 Ambient air temperature -30? ~ +65? at storage -5? ~ +55? at operation (AC type) Operating altitude 3000m(8900ft) Shock resistance (1/2 sin wave=11ms) 8G at opened 10G at closed Vibration resistance (Conforming to IEC68-2-6) (5~300Hz) 2G at opened 4G at closed Flame resistance V0 at conforming to UL94 960? at conforming to IEC695-2-1 REACH Yes RoHS Yes WEEE Yes Dimensions Weight 0.5kg Size width 57mm / 2.24inch Size height 83mm / 3.27inch Size depth 90mm / 3.54inch Control coil Control voltage AC120V 50/60Hz Control voltage limit [Uc] 85~110% Consumption at 20℃ 90VA at inrush 9VA at holding Heat dissipation 2.7W at holding Operating time 15~30ms at closing 4~19ms at opening Applicable Accessories

  • Schneider Electric circuit breaker Easypact EZC100F - TMD - 100 A - 3 poles 3d EZC100F3100

    Schneider Electric Schneider Electric circuit breaker Easypact EZC100F - TMD - 100 A - 3 poles 3d EZC100F3100

    Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 100A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 100 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards EN/IEC 60947-1JIS C8201-2-2GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14 cm Package 1 Weight 808 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 9.887 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 328 kg

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 40A

    General Product code 0134001800 Product description ABH103c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

    $111.57

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 30A

    General Product code 0134001700 Product description ABH103c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

    $111.57

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH204c 200A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH204c 200A

    General Product code 0141000500 Product description ABH204c 200A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 200 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-46 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 165 mm Depth 60 mm Weight 1.6 kg Packing Width 310 mm Height 525 mm Depth 105 mm Weight 9 kg Quantity (in a box) 5 pcs.

    $230.36

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH403c 400A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH403c 400A

    General Product code 0164003200 Product description ABH403c 400A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 400 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 70 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 50 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 40 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 70 kA at 380 V AC 50/60 Hz, IEC 60947-2 65 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 50 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 40 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 154 kA at 380 V AC 50/60 Hz, IEC 60947-2 143 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 105 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-57 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.

    $343.57

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN52c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN52c 40A

    General Product code 0128002600 Product description ABN52c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 5 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 5 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 63 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 36 kA at 380 V AC 50/60 Hz, IEC 60947-2 28 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 12.75 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-5 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 50 mm Height 130 mm Depth 60 mm Weight 0.5 kg Packing Width 385 mm Height 570 mm Depth 105 mm Weight 11.5 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN53c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN53c 30A

    General Product code 0129006600 Product description ABN53c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 63 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 36 kA at 380 V AC 50/60 Hz, IEC 60947-2 28 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 12.75 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-6 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN103c 60A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN103c 60A

    General Product code 0131008200 Product description ABN103c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-18 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS33c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS33c 30A

    General Product code 0129002100 Product description ABS33c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 63 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 36 kA at 380 V AC 50/60 Hz, IEC 60947-2 28 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 12.75 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-3 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS33c 15A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS33c 15A

    General Product code 0129001900 Product description ABS33c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 30 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 18 kA at 380 V AC 50/60 Hz, IEC 60947-2 14 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 5 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 63 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 36 kA at 380 V AC 50/60 Hz, IEC 60947-2 28 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 12.75 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-3 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS33c 5A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS33c 5A

    General Product code 0129001700 Product description ABS33c 5A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 5 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 25 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 14 kA at 380 V AC 50/60 Hz, IEC 60947-2 10 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, Reference - 5 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 25 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 14 kA at 380 V AC 50/60 Hz, IEC 60947-2 10 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 2.5 kA at 690 V AC 50/60 Hz, Reference - 5 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 52.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 28 kA at 380 V AC 50/60 Hz, IEC 60947-2 17 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 3.75 kA at 690 V AC 50/60 Hz, IEC 60947-2 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS63c 60A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS63c 60A

    General Product code 0131002500 Product description ABS63c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 35 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 22 kA at 380 V AC 50/60 Hz, IEC 60947-2 18 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 10 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 73.5 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 46.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 36 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 17 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-15 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - - EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 75 mm Height 130 mm Depth 60 mm Weight 0.7 kg Packing Width 435 mm Height 565 mm Depth 105 mm Weight 15.8 kg Quantity (in a box) 20 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS103c 75A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS103c 75A

    General Product code 0134000700 Product description ABS103c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 20 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-30 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABS202c 100A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABS202c 100A

    General Product code 0136000100 Product description ABS202c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 85 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 26 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 20 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 187 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-41 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.1 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 12 kg Quantity (in a box) 10 pcs.

    $154.84

  • IDEC NH1V-1500-DC24 Photo on request Genuine IDEC part

    IDEC IDEC NH1V-1500 Series NH1V-1500-DC24

    IDEC NH1V-1500-DC24 — NH1V-1500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Rated Breaking Capacity (kA) Protection Method NH1V-1500-DC24 1 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-3100-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-3100 Series

    IDEC NH1V-3100 — NH1V-3100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-3100-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-2AD 3 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-0.75MA 3 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-2AD 3 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-30MA 3 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3100F-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $109.22

  • IDEC NH1V-3111-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-3111 Series

    IDEC NH1V-3111 — NH1V-3111 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-3111-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-0.75MA 3 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-20AD 3 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-30MA 3 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-0.75MA 3 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-30MA 3 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3111F-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $118.45

  • IDEC NH1V-2111-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-2111 Series

    IDEC NH1V-2111 — NH1V-2111 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-2111-0.5AA 2 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-0.5AD 2 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-0.75AA 2 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-0.75AD 2 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-10AA 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-10AD 2 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-10MA 2 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-15AA 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-15AD 2 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-1AA 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-1AD 2 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-20AA 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-20AD 2 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-25AA 2 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-25AD 2 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-2AA 2 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-2AD 2 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-2MA 2 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-30AA 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-30AD 2 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-3AA 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-3AD 2 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-3MA 2 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-5AA 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-5AD 2 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-5MA 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-5MD 2 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-7.5AA 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-7.5AD 2 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111-7.5MA 2 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-0.5AA 2 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-0.5MA 2 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-0.75AA 2 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-0.75MA 2 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-10AA 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-10MA 2 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-15AA 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-15AD 2 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-15MA 2 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-1AA 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-1MA 2 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-20AA 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-20MA 2 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-25AA 2 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-25MA 2 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-25MD 2 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-2AA 2 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-2MA 2 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-30AA 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-30MA 2 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-3AA 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-3MA 2 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-5AA 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-5MA 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-7.5AA 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2111F-7.5MA 2 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-3121-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-3121 Series

    IDEC NH1V-3121 — NH1V-3121 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-3121-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-0.75MA 3 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-2AD 3 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-30MA 3 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121F-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121F-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121F-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121F-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121F-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-3121F-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $120.76

  • IDEC NRAN2500-DC24V Photo on request Genuine IDEC part

    IDEC IDEC NRAN2500 Series NRAN2500-DC24V

    IDEC NRAN2500-DC24V — NRAN2500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Rated Breaking Capacity (kA) Protection Method NRAN2500-DC24V 2 AC250/DC65 30 (AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-1100F-3AD Photo on request Genuine IDEC part

    IDEC IDEC NH1V-1100 Series, NH1V-1100F (Part 2)

    IDEC NH1V-1100F — NH1V-1100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-1100F-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-3BA 1 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-5BA 1 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-7.5MD 1 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-26-3AA100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-26-3 Series

    IDEC NH1S-26 — NH1S-26-3 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-26-3AA100 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-3AA12 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-3AA24 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-3BA24 2 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $103.07

  • IDEC NH1S-26-5AA100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-26-5 Series

    IDEC NH1S-26 — NH1S-26-5 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-26-5AA100 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-5AA24 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-5AA50 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $103.07

  • IDEC NH1V-2500-AC100 Photo on request Genuine IDEC part

    IDEC IDEC NH1V-2500 Series

    IDEC NH1V-2500 — NH1V-2500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Rated Breaking Capacity (kA) Protection Method NH1V-2500-AC100 2 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2500-DC24 2 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-16-2AA100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-16-2 Series

    IDEC NH1S-16 — NH1S-16-2 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-16-2AA100 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-2AD24 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-2BA24 1 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-1100-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-1100 Series (Part 1)

    IDEC NH1V-1100 — NH1V-1100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-1100-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.5BA 1 AC250/DC65 0.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.5MA 1 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.5MD 1 AC250/DC65 0.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.75BA 1 AC250/DC65 0.75 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.75MA 1 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-0.75MD 1 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-10BA 1 AC250/DC65 10 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-10MD 1 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-15BA 1 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-15MA 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-1BA 1 AC250/DC65 1 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-20BA 1 AC250/DC65 20 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-25BA 1 AC250/DC65 25 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-25MA 1 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-25MD 1 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-2BA 1 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-2MD 1 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-30BA 1 AC250/DC65 30 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-30MA 1 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-30MD 1 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-3BA 1 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-5BA 1 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-7.5BA 1 AC250/DC65 7.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100-7.5MD 1 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.5BA 1 AC250/DC65 0.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.5MA 1 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.5MD 1 AC250/DC65 0.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.75MA 1 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-0.75MD 1 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-10MD 1 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-15MA 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-1BA 1 AC250/DC65 1 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-25MA 1 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-25MD 1 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-2BA 1 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-2MD 1 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-30MA 1 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-30MD 1 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1100F-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-16-10AD24 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-16-1 Series

    IDEC NH1S-16 — NH1S-16-1 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-16-10AD24 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-10AD50 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-15AA100 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-15AA24 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-15MA100 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NRAN1500-DC24V Photo on request Genuine IDEC part

    IDEC IDEC NRAN1500 Series NRAN1500-DC24V

    IDEC NRAN1500-DC24V — NRAN1500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Rated Breaking Capacity (kA) Protection Method NRAN1500-DC24V 1 AC250/DC65 30 (AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1Y-1500-DC24V Photo on request Genuine IDEC part

    IDEC IDEC NH1Y-1500 Series, NH1Y-1500-DC24V

    IDEC NH1Y-1500-DC24V — NH1Y-1500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Rated Breaking Capacity (kA) Protection Method NH1Y-1500-DC24V 1 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1Y-1500-DC24VD 1 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1Y-1500-DC24VDW 1 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1Y-2500-AC100VAR Photo on request Genuine IDEC part

    IDEC IDEC NH1Y-2500 Series

    IDEC NH1Y-2500 — NH1Y-2500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Rated Breaking Capacity (kA) Protection Method NH1Y-2500-AC100VAR 2 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1Y-2500-AC100VW 2 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1Y-2500-DC24VD 2 AC250/DC65 30 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-16-5AA100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-16-5 Series

    IDEC NH1S-16 — NH1S-16-5 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-16-5AA100 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-16-5AD24 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-26-7.5AA100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-26-7 Series

    IDEC NH1S-26 — NH1S-26-7 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-26-7.5AA100 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-7.5BA100 2 AC250/DC65 7.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $103.07

  • IDEC NH1V-1121-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-1121 Series

    IDEC NH1V-1121 — NH1V-1121 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-1121-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.5MA 1 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.5MD 1 AC250/DC65 0.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.75MA 1 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-0.75MD 1 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-10MD 1 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-15MA 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-25MA 1 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-25MD 1 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-2MD 1 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-30MA 1 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-30MD 1 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121-7.5MD 1 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1121F-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-16-3AA24 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-16-3 Series NH1S-16-3AA24

    IDEC NH1S-16-3AA24 — NH1S-16-3 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-16-3AA24 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-1500-DC24V Photo on request Genuine IDEC part

    IDEC IDEC NH1S-1500 Series NH1S-1500-DC24V

    IDEC NH1S-1500-DC24V — NH1S-1500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Breaking Capacity (kA) Protection Method NH1S-1500-DC24V 1 AC250/DC65 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-2100F-5MA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-2100 Series, NH1V-2100F (Part 2)

    IDEC NH1V-2100F — NH1V-2100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-2100F-5MA 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-7.5AA 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-7.5AD 2 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-7.5BA 2 AC250/DC65 7.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-7.5MA 2 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-1111-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-1111 Series

    IDEC NH1V-1111 — NH1V-1111 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-1111-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-0.5MA 1 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-2MD 1 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111-7.5MD 1 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-3BA 1 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-5BA 1 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-1111F-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-2500-AC100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-2500 Series

    IDEC NH1S-2500 — NH1S-2500 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Breaking Capacity (kA) Protection Method NH1S-2500-AC100 2 AC250/DC65 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-2500-DC24V 2 AC250/DC65 (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1V-2100-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1V-2100 Series (Part 1)

    IDEC NH1V-2100 — NH1V-2100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1V-2100-0.5AA 2 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.5AD 2 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.5BA 2 AC250/DC65 0.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.5MA 2 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.5MD 2 AC250/DC65 0.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.75AA 2 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.75AD 2 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.75BA 2 AC250/DC65 0.75 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.75MA 2 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-0.75MD 2 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-10AD 2 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-10BA 2 AC250/DC65 10 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-10MA 2 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-10MD 2 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-15AD 2 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-15BA 2 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-15MA 2 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-15MD 2 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-1AD 2 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-1BA 2 AC250/DC65 1 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-1MA 2 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-1MD 2 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-20AA 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-20AD 2 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-20BA 2 AC250/DC65 20 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-20MA 2 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-20MD 2 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-25AA 2 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-25AD 2 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-25BA 2 AC250/DC65 25 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-25MA 2 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-25MD 2 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-2AD 2 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-2BA 2 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-2MA 2 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-2MD 2 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-30AA 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-30AD 2 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-30BA 2 AC250/DC65 30 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-30MA 2 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-30MD 2 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-3AD 2 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-3BA 2 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-3MA 2 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-3MD 2 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-5AD 2 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-5BA 2 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-5MA 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-5MD 2 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-7.5AA 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-7.5AD 2 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-7.5BA 2 AC250/DC65 7.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-7.5MA 2 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100-7.5MD 2 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.5AA 2 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.5AD 2 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.5BA 2 AC250/DC65 0.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.5MA 2 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.75AA 2 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.75AD 2 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.75BA 2 AC250/DC65 0.75 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.75MA 2 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-0.75MD 2 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-10AA 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-10AD 2 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-10BA 2 AC250/DC65 10 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-10MA 2 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-15AA 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-15AD 2 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-15BA 2 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-15MA 2 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-1AA 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-1AD 2 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-1BA 2 AC250/DC65 1 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-1MA 2 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-20AA 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-20AD 2 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-20BA 2 AC250/DC65 20 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-20MA 2 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-20MD 2 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-25AA 2 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-25AD 2 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-25BA 2 AC250/DC65 25 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-25MA 2 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-2AA 2 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-2AD 2 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-2BA 2 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-2MA 2 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-30AA 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-30AD 2 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-30BA 2 AC250/DC65 30 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-30MA 2 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-3AA 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-3AD 2 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-3BA 2 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-3MA 2 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-3MD 2 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-5AA 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-5AD 2 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1V-2100F-5BA 2 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-3100-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1S-3100 Series

    IDEC NH1S-3100 — NH1S-3100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-3100-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-0.75MA 3 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-10BA 3 AC250/DC65 10 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-2BA 3 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-30MA 3 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-0.5AA 3 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-0.75AA 3 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-0.75MA 3 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-1MA 3 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-25MA 3 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-2MA 3 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-30MA 3 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100F-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-10BA 3 AC250/DC65 10 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-20BA 3 AC250/DC65 20 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-20MA 3 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-30BA 3 AC250/DC65 30 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-5MA 3 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100FS-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-0.5MA 3 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-10AA 3 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-10MA 3 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-15AA 3 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-15MA 3 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-1AA 3 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-20AA 3 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-25AA 3 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-2AA 3 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-2BA 3 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-30AA 3 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-3AA 3 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-3BA 3 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-3MA 3 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-5AA 3 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-7.5AA 3 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-3100S-7.5MA 3 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-26-10AA100 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-26-1 Series

    IDEC NH1S-26 — NH1S-26-1 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-26-10AA100 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-15AA100 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-15AA24 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-15AD24 2 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-15BA100 2 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-26-15BA24 2 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

    $103.07

  • IDEC NH1L-2100FS-5BA1AR Photo on request Genuine IDEC part

    IDEC IDEC NH1L-2100 Series (Part 5)

    IDEC NH1L — NH1L-2100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1L-2100FS-5BA1AR 2 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-5MA1 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-5MA1AW 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-5MA5AG 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-7.5AA1 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-7.5AA1A 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-7.5AA1DG 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-7.5BA1AW 2 AC250/DC65 7.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100FS-7.5MA1C 2 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-0.5AA1 2 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-0.75MA1A 2 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA1 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA1A 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA1C 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA1CG 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA3 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA5 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AA5AW 2 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10AD5 2 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10MA1 2 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-10MA4 2 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15AA1 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15AA1A 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15AA1AG 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15AA5 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15AA5A 2 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15BA1R 2 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15BA5A 2 AC250/DC65 15 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-15MA3A 2 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1AA1 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1AA1A 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1AA1AW 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1AA4AR 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1AA5 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1AA5A 2 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1MA1 2 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-1MA1A 2 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-20AA1 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-20AA1A 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-20AA1C 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-20AA1D 2 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-25AA1 2 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-25MD4 2 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-2AA1 2 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-2AA1A 2 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-2AA5 2 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-2BA4 2 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-2MA1A 2 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-2MA5CG 2 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-30AA1 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-30AA1D 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-30AA5 2 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA1 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA1A 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA1AR 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA1CR 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA4 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA5 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AA5A 2 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3AD5A 2 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3BA1AR 2 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3BA5AR 2 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-3MA3A 2 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AA1 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AA1A 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AA1AG 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AA4 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AA5 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AA5AW 2 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5AD5G 2 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5BA1 2 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5BA1D 2 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5BA1R 2 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5MA1 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-5MA4AG 2 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-7.5AA1 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-7.5AA1AG 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-7.5AA1AW 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-7.5AA1R 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1L-2100S-7.5AA5 2 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-16-7.5AA24 Photo on request Genuine IDEC part

    IDEC IDEC NH1S-16-7 Series NH1S-16-7.5AA24

    IDEC NH1S-16-7.5AA24 — NH1S-16-7 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-16-7.5AA24 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-1100F-7.5AD Photo on request Genuine IDEC part

    IDEC IDEC NH1S-1100 Series (Part 2)

    IDEC NH1S — NH1S-1100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-1100F-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-7.5BA 1 AC250/DC65 7.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-7.5MD 1 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-10MD 1 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-30MD 1 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-3BA 1 AC250/DC65 3 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100FS-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-10BA 1 AC250/DC65 10 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-15MA 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-5BA 1 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100S-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request

  • IDEC NH1S-1100-0.5AA Photo on request Genuine IDEC part

    IDEC IDEC NH1S-1100 Series (Part 1)

    IDEC NH1S-1100 — NH1S-1100 Series, genuine IDEC product.OverviewIDEC circuit protectors (NRF, NRA, NRL, NH1 series) protect control circuits and equipment against overcurrent with compact DIN rail or panel mounting.Key Features Genuine IDEC circuit protector Select by rated current, poles and tripping characteristic Compact design for control panels Specifications Part No. Number of Poles Rated Voltage (V) Rated Current (A) Operating Characteristics Rated Breaking Capacity (kA) Protection Method NH1S-1100-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.5MA 1 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.5MD 1 AC250/DC65 0.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.75BA 1 AC250/DC65 0.75 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.75MA 1 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-0.75MD 1 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-10MD 1 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-15MA 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-1BA 1 AC250/DC65 1 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-25MA 1 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-25MD 1 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-2BA 1 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-2MD 1 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-30MA 1 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-30MD 1 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-7.5AD 1 AC250/DC65 7.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-7.5MA 1 AC250/DC65 7.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100-7.5MD 1 AC250/DC65 7.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.5AA 1 AC250/DC65 0.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.5AD 1 AC250/DC65 0.5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.5BA 1 AC250/DC65 0.5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.5MA 1 AC250/DC65 0.5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.5MD 1 AC250/DC65 0.5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.75AA 1 AC250/DC65 0.75 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.75AD 1 AC250/DC65 0.75 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.75BA 1 AC250/DC65 0.75 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.75MA 1 AC250/DC65 0.75 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-0.75MD 1 AC250/DC65 0.75 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-10AA 1 AC250/DC65 10 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-10AD 1 AC250/DC65 10 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-10MA 1 AC250/DC65 10 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-10MD 1 AC250/DC65 10 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-15AA 1 AC250/DC65 15 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-15AD 1 AC250/DC65 15 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-15MA 1 AC250/DC65 15 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-15MD 1 AC250/DC65 15 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-1AA 1 AC250/DC65 1 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-1AD 1 AC250/DC65 1 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-1BA 1 AC250/DC65 1 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-1MA 1 AC250/DC65 1 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-1MD 1 AC250/DC65 1 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-20AA 1 AC250/DC65 20 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-20AD 1 AC250/DC65 20 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-20MA 1 AC250/DC65 20 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-20MD 1 AC250/DC65 20 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-25AA 1 AC250/DC65 25 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-25AD 1 AC250/DC65 25 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-25MA 1 AC250/DC65 25 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-25MD 1 AC250/DC65 25 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-2AA 1 AC250/DC65 2 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-2AD 1 AC250/DC65 2 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-2BA 1 AC250/DC65 2 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-2MA 1 AC250/DC65 2 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-2MD 1 AC250/DC65 2 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-30AA 1 AC250/DC65 30 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-30AD 1 AC250/DC65 30 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-30MA 1 AC250/DC65 30 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-30MD 1 AC250/DC65 30 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-3AA 1 AC250/DC65 3 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-3AD 1 AC250/DC65 3 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-3MA 1 AC250/DC65 3 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-3MD 1 AC250/DC65 3 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-5AA 1 AC250/DC65 5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-5AD 1 AC250/DC65 5 Medium Type (AD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-5BA 1 AC250/DC65 5 High-Speed Type (BA Characteristic) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-5MA 1 AC250/DC65 5 Slow Type (MA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-5MD 1 AC250/DC65 5 Slow Type (MD Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip NH1S-1100F-7.5AA 1 AC250/DC65 7.5 Medium Type (AA Curve) (AC220V/AC250V/DC65V)1 Hydraulic-Magnetic Trip How to OrderSelect the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.About IDECIDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.Ordering & Shipping Genuine IDEC product sourced through Korean distribution Lead time varies by model; most items ship within 2-3 weeks Ships worldwide from South Korea by FedEx International Priority Express Import duties and taxes are payable by the recipient Bulk and trade pricing available on request