Fuji Electric command switches and indicators of the AR/DR, AH and AF series, including pushbuttons, illuminated buttons, selector switches, pilot lights, buzzers and control boxes.
| Part No. |
Mass (g) |
Type |
Type |
Specification |
Protective Structure |
Contact Configuration |
Frame |
Withstand Voltage |
Insulation Voltage (V) |
Notch Angle (°) |
Number of Notches |
Operating Method |
| AR30JAR-0A10A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JAR-0A11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JAR-2A10A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2A10B |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2A10C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2A11B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2A20A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2A22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2B11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2D10A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2D11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-2D22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JAR-3C11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
3 |
Manual |
| AR30JAR-3E11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
3 |
Manual |
| AR30JR-0A10A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JR-0A11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JR-0A11B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JR-0A11C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JR-0A22C |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
60 |
2 |
Auto |
| AR30JR-1E20A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-1E22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Auto |
| AR30JR-2A01A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A01C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A03A |
- |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
3b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10AZ9 |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10AZM |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10B |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10CZ9 |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10D |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10E |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A10F |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11AZ9 |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11AZM |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11D |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11E |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A11F |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A20B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A20C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A20D |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A20E |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A22B |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A22C |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A30A |
- |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
3a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A33A |
- |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
3a3b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2A40A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
4a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B01A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B01C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B01D |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B01E |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B02A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B10A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B10B |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B10C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B10D |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B10E |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B11B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B11BZM |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B11C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B11CZM |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B20A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B20B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B20D |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B22BZM |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2B22C |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D01A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D01C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D10A |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D10B |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D10C |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D10D |
67 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D11B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D11C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D11D |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D11E |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D11F |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-2D22C |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
90 |
2 |
Manual |
| AR30JR-3A11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3B11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3C11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3C11C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3C11D |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3C22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3C22AZB |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3D11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3E11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3E11B |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3E11C |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3E22A |
94 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
2a2b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-3G11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Manual |
| AR30JR-7A11A |
76 |
Standard Type |
Selector Switch |
UL, CSA, EN Standard (TUV), CE, CCC |
IP65 (Oil-Proof Type) |
1a1b |
Round Frame |
Live Parts to Ground / Between Live Parts of Different Poles: AC2500V for 1 min |
AC/DC600 |
45 |
3 |
Mixed |
Select the exact part number from the options. Fuji Electric Japanese-market part numbers encode coil voltage, ratings and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.