Fuji Electric SW series magnetic starters combine a magnetic contactor and thermal overload relay to switch and protect three-phase motors.
| Part No. |
Accessories |
Capacity (kW) |
Type |
Protective Structure |
Frame |
Operating Method |
Reset Method |
Auxiliary Contact |
Main Circuit Voltage (V) |
Motor Capacity (kW) |
Coil Voltage (V) |
Heater Element Nominal Rating (A) |
| SW-03/2E/T 200V0.75KW AC200V1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 03 |
Non-Reversing |
Manual |
1a |
200 |
0.75 |
AC200 |
- |
| SW-03/2E/T 200V1.5KW AC200V 1A |
With 2E Thermal Overload Relay |
1.5 |
Magnetic Starter |
Without Case Cover |
Type 03 |
Non-Reversing |
Manual |
1a |
200 |
1.5 |
AC200 |
|
| SW-05/2E 0.15A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.15 |
| SW-05/2E 0.24A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.24 |
| SW-05/2E 0.2A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.2 |
| SW-05/2E 0.36A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.36 |
| SW-05/2E 0.3A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.3 |
| SW-05/2E 0.48A coil AC220V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC220 |
0.48 |
| SW-05/2E 0.64A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.64 |
| SW-05/2E 0.64A coil AC200V 2A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
2a |
- |
- |
AC200 |
0.64 |
| SW-05/2E 0.8A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
0.8 |
| SW-05/2E 1.4A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
1.4 |
| SW-05/2E 1.7A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
1.7 |
| SW-05/2E 2.2A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
2.2 |
| SW-05/2E 2.8A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
2.8 |
| SW-05/2E 200V0.1KW AC200V 1A1B |
With 2E Thermal Overload Relay |
0.1 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
200 |
0.1 |
AC200 |
|
| SW-05/2E 200V0.2KW AC200V 1A1B |
With 2E Thermal Overload Relay |
0.2 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
200 |
0.2 |
AC200 |
|
| SW-05/2E 200V0.4KW AC200V 1A1B |
With 2E Thermal Overload Relay |
0.4 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
200 |
0.4 |
AC200 |
|
| SW-05/2E 200V0.4KW coil AC200V2A |
With 2E Thermal Overload Relay |
0.4 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
2a |
200 |
0.4 |
AC200 |
|
| SW-05/2E 200V0.75KW AC200V 2A |
With 2E Thermal Overload Relay |
0.75 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
2a |
200 |
0.75 |
AC200 |
|
| SW-05/2E 200V0.75KW AC200V1A1B |
With 2E Thermal Overload Relay |
0.75 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
200 |
0.75 |
AC200 |
|
| SW-05/2E 200V1.5KW AC200V 1A1B |
With 2E Thermal Overload Relay |
1.5 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
200 |
1.5 |
AC200 |
|
| SW-05/2E 200V1.5KW AC200V 2A |
With 2E Thermal Overload Relay |
1.5 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
2a |
200 |
1.5 |
AC200 |
|
| SW-05/2E 200V2.2KW AC200V 1A1B |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
200 |
2.2 |
AC200 |
|
| SW-05/2E 200V2.2KW AC200V 2A |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
2a |
200 |
2.2 |
AC200 |
|
| SW-05/2E 4A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
4 |
| SW-05/2E 5A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
5 |
| SW-05/2E 6A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
6 |
| SW-05/2E 7A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
7 |
| SW-05/2E 9A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 05 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
9 |
| SW-4-0/2E 200V2.2KW AC200V 1A |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 4-0 |
Non-Reversing |
Manual |
1a |
200 |
2.2 |
AC200 |
|
| SW-4-0/2E 200V3.7KW AC200V 1A |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type 4-0 |
Non-Reversing |
Manual |
1a |
200 |
3.7 |
AC200 |
|
| SW-4-0/2E 9A coil AC200V 1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-0 |
Non-Reversing |
Manual |
1a |
- |
- |
AC200 |
9 |
| SW-4-0/2E/A 200V3.7KW AC200V1A |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type 4-0 |
Non-Reversing |
Auto |
1a |
200 |
3.7 |
AC200 |
|
| SW-4-1/2E 12A coil AC200V 1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
- |
- |
AC200 |
12 |
| SW-4-1/2E 12A coil AC200V 1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1b |
- |
- |
AC200 |
12 |
| SW-4-1/2E 2.8A coil AC200V 1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
- |
- |
AC200 |
2.8 |
| SW-4-1/2E 200V2.2KW AC200V 1A |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
200 |
2.2 |
AC200 |
|
| SW-4-1/2E 200V3.7KW AC200V 1A |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
200 |
3.7 |
AC200 |
|
| SW-4-1/2E 5A coil AC200V 1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
- |
- |
AC200 |
5 |
| SW-4-1/2E 7A coil AC200V 1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
- |
- |
AC200 |
7 |
| SW-4-1/2E 9A coil AC200V 1A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 4-1 |
Non-Reversing |
Manual |
1a |
- |
- |
AC200 |
9 |
| SW-5-1/2E 1.4A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
1.4 |
| SW-5-1/2E 1.4A coil AC200V 2A2B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
1.4 |
| SW-5-1/2E 12A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
12 |
| SW-5-1/2E 12A coil AC220V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC220 |
12 |
| SW-5-1/2E 2.2A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
2.2 |
| SW-5-1/2E 2.2A coil AC200V 2A2B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
2.2 |
| SW-5-1/2E 2.8A coil AC200V 2A |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a |
- |
- |
AC200 |
2.8 |
| SW-5-1/2E 200V0.1KW AC200V1A1B |
With 2E Thermal Overload Relay |
0.1 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
0.1 |
AC200 |
|
| SW-5-1/2E 200V0.2KW AC200V1A1B |
With 2E Thermal Overload Relay |
0.2 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
0.2 |
AC200 |
|
| SW-5-1/2E 200V0.4KW AC200V1A1B |
With 2E Thermal Overload Relay |
0.4 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
0.4 |
AC200 |
|
| SW-5-1/2E 200V0.75KWAC200V1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
0.75 |
AC200 |
- |
| SW-5-1/2E 200V0.75KWAC200V2A2B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
200 |
0.75 |
AC200 |
- |
| SW-5-1/2E 200V1.5KWAC200V1A1B |
With 2E Thermal Overload Relay |
1.5 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
1.5 |
AC200 |
|
| SW-5-1/2E 200V2.2KW AC200V1A1B |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
2.2 |
AC200 |
|
| SW-5-1/2E 200V2.2KW AC200V2A |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a |
200 |
2.2 |
AC200 |
|
| SW-5-1/2E 200V2.2KW AC200V2A2B |
With 2E Thermal Overload Relay |
2.2 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
200 |
2.2 |
AC200 |
|
| SW-5-1/2E 200V3.7KW AC200V1A1B |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
200 |
3.7 |
AC200 |
|
| SW-5-1/2E 200V3.7KW AC200V2A |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a |
200 |
3.7 |
AC200 |
|
| SW-5-1/2E 200V3.7KW AC200V2A2B |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
200 |
3.7 |
AC200 |
|
| SW-5-1/2E 4A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
4 |
| SW-5-1/2E 4A coil AC200V 2A2B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
4 |
| SW-5-1/2E 6A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
6 |
| SW-5-1/2E 6A coil AC200V 2A2B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
6 |
| SW-5-1/2E 6A coil AC400V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC400 |
6 |
| SW-5-1/2E 9A coil AC200V 1A1B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
1a1b |
- |
- |
AC200 |
9 |
| SW-5-1/2E 9A coil AC200V 2A2B |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type 5-1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
9 |
| SW-N1/2E 12A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
12 |
| SW-N1/2E 18A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
18 |
| SW-N1/2E 200V 3.7KW coil AC200V |
With 2E Thermal Overload Relay |
3.7 |
Magnetic Starter |
Without Case Cover |
Type N1 |
Non-Reversing |
Manual |
2a2b |
200 |
3.7 |
AC200 |
|
| SW-N1/2E 200V 5.5KW coil AC200V |
With 2E Thermal Overload Relay |
5.5 |
Magnetic Starter |
Without Case Cover |
Type N1 |
Non-Reversing |
Manual |
2a2b |
200 |
5.5 |
AC200 |
|
| SW-N1/2E/T 18A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N1 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
18 |
| SW-N1/2E/T 200V5.5KW coil AC200V |
With 2E Thermal Overload Relay |
5.5 |
Magnetic Starter |
Without Case Cover |
Type N1 |
Non-Reversing |
Manual |
2a2b |
200 |
5.5 |
AC200 |
|
| SW-N10/2E 200V 55KW coil 200V |
With 2E Thermal Overload Relay |
55 |
Magnetic Starter |
Without Case Cover |
Type N10 |
Non-Reversing |
Manual |
2a2b |
200 |
55 |
200 |
|
| SW-N2/2E 200V5.5KW coil AC200V |
With 2E Thermal Overload Relay |
5.5 |
Magnetic Starter |
Without Case Cover |
Type N2 |
Non-Reversing |
Manual |
2a2b |
200 |
5.5 |
AC200 |
|
| SW-N2/2E 200V7.5KW coil AC200V |
With 2E Thermal Overload Relay |
7.5 |
Magnetic Starter |
Without Case Cover |
Type N2 |
Non-Reversing |
Manual |
2a2b |
200 |
7.5 |
AC200 |
|
| SW-N2/2E 24A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N2 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
24 |
| SW-N2/2E 32A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N2 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
32 |
| SW-N2/2E/A 24A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N2 |
Non-Reversing |
Auto |
2a2b |
- |
- |
AC200 |
24 |
| SW-N2/2E/T 200V7.5KW coil AC200V |
With 2E Thermal Overload Relay |
7.5 |
Magnetic Starter |
Without Case Cover |
Type N2 |
Non-Reversing |
Manual |
2a2b |
200 |
7.5 |
AC200 |
|
| SW-N2S/2E 200V11KW coil AC200V |
With 2E Thermal Overload Relay |
11 |
Magnetic Starter |
Without Case Cover |
Type N2S |
Non-Reversing |
Manual |
2a2b |
200 |
11 |
AC200 |
|
| SW-N2S/2E 200V7.5KW coil AC200V |
With 2E Thermal Overload Relay |
7.5 |
Magnetic Starter |
Without Case Cover |
Type N2S |
Non-Reversing |
Manual |
2a2b |
200 |
7.5 |
AC200 |
|
| SW-N2S/2E 28A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N2S |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
28 |
| SW-N2S/2E 34A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N2S |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
34 |
| SW-N2S/2E 45A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N2S |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
45 |
| SW-N3/2E 200V11KW coil AC200V |
With 2E Thermal Overload Relay |
11 |
Magnetic Starter |
Without Case Cover |
Type N3 |
Non-Reversing |
Manual |
2a2b |
200 |
11 |
AC200 |
|
| SW-N3/2E 200V15KW coil AC200V |
With 2E Thermal Overload Relay |
15 |
Magnetic Starter |
Without Case Cover |
Type N3 |
Non-Reversing |
Manual |
2a2b |
200 |
15 |
AC200 |
|
| SW-N3/2E 45A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N3 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
45 |
| SW-N4/2E 18A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
18 |
| SW-N4/2E 18A coil AC220V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC220 |
18 |
| SW-N4/2E 200V15KW coil AC200V |
With 2E Thermal Overload Relay |
15 |
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
200 |
15 |
AC200 |
|
| SW-N4/2E 200V18.5KW coil AC200V |
With 2E Thermal Overload Relay |
18.5 |
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
200 |
18.5 |
AC200 |
|
| SW-N4/2E 24A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
24 |
| SW-N4/2E 24A coil AC220V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC220 |
24 |
| SW-N4/2E 28A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
28 |
| SW-N4/2E 28A coil AC220V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC220 |
28 |
| SW-N4/2E 34A coil AC200V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC200 |
34 |
| SW-N4/2E 34A coil AC220V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC220 |
34 |
| SW-N4/2E 45A coil AC120V |
With 2E Thermal Overload Relay |
|
Magnetic Starter |
Without Case Cover |
Type N4 |
Non-Reversing |
Manual |
2a2b |
- |
- |
AC120 |
45 |
Select the exact part number from the options. Fuji Electric Japanese-market part numbers encode coil voltage, ratings and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.
Fuji Electric is a Japanese manufacturer of power electronics and industrial systems, producing FRENIC inverters, servo systems, MICREX PLCs, magnetic contactors and starters, G-TWIN circuit breakers and command switches used in factories, buildings and infrastructure worldwide.