Fuji Electric Standard Limit Switch K244 - K244G-2

Description

Fuji Electric K244 — Standard Limit Switch K244, genuine Fuji Electric product.

Overview

Genuine Fuji Electric low-voltage control and power distribution component.

Key Features

  • Genuine Fuji Electric product
  • Confirm the full part number against your existing part before ordering

Specifications

Part No. Protective Structure Contact Configuration Allowable Current (A) Dimension A (mm) Withstand Voltage Dimension B (mm) Dimension C (mm) Repeatability (mm) Insulation Resistance (MΩ) Operating Ambient Temperature (℃) Shock (Durability) (m/s2) Vibration Resistance (Durability)
K244G-2 With Metal Case Cover 1a1b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2/2 With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2/2U With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2S With Metal Case Cover 1a1b 10 (Continuous) 24 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2S/2S With Metal Case Cover 2a2b 10 (Continuous) 24 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2U With Metal Case Cover 1a1b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2U/2U With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2V With Metal Case Cover 1a1b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244G-2V/2V With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GO-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GO-2S/2S Oil-Tight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GOR-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GOR-2S/2S Oil-Tight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GORF-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GORL-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GR-2/2 With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GR-2/2U With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GR-2S/2S With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - 0.3 or less (K244gR-2S) 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GR-2U With Metal Case Cover 1a1b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GR-2U/2U With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GR-2V With Metal Case Cover 1a1b 10 (Continuous) 57 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRF-2 With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRF-2S With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - 0.3 or less (K244gR-2S) 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRF-2U With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRF-2V With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRF-2V/2V With Metal Case Cover 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRL-2 With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRL-2S With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - 0.3 or less (K244gR-2S) 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRL-2U With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GRL-2V With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GW-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GW-2S/2S Watertight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GWR-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GWR-2S/2S Watertight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GWRF-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244GWRL-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244XP-2U With Plastic Cover 1a1b 10 (Continuous) 21 AC2500V 1 min 1.5 6 - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
K244XP-2V With Plastic Cover 1a1b 10 (Continuous) 21 AC2500V 1 min 1 8.5 - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)

How to Order

Select the exact part number from the options. Fuji Electric Japanese-market part numbers encode coil voltage, ratings and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.

About Fuji Electric

Fuji Electric is a Japanese manufacturer of power electronics and industrial systems, producing FRENIC inverters, servo systems, MICREX PLCs, magnetic contactors and starters, G-TWIN circuit breakers and command switches used in factories, buildings and infrastructure worldwide.

Ordering & Shipping

  • Genuine Fuji Electric product sourced through Korean distribution
  • Lead time varies by model; most items ship within 2-3 weeks
  • Ships worldwide from South Korea by FedEx International Priority Express
  • Import duties and taxes are payable by the recipient
  • Bulk and trade pricing available on request
Product form

Fuji Electric K244 — Standard Limit Switch K244, genuine Fuji Electric product.OverviewGenuine Fuji Electric low-voltage control and power distribution component.Key... Read more

SKU: K244G-2

$67.68 Excl. VAT

    • Ships within 5–10 business days
    • Ships from South Korea
    • Export packing available
    • Worldwide shipping
    • Secure payments Paypal

    Description

    Fuji Electric K244 — Standard Limit Switch K244, genuine Fuji Electric product.

    Overview

    Genuine Fuji Electric low-voltage control and power distribution component.

    Key Features

    • Genuine Fuji Electric product
    • Confirm the full part number against your existing part before ordering

    Specifications

    Part No. Protective Structure Contact Configuration Allowable Current (A) Dimension A (mm) Withstand Voltage Dimension B (mm) Dimension C (mm) Repeatability (mm) Insulation Resistance (MΩ) Operating Ambient Temperature (℃) Shock (Durability) (m/s2) Vibration Resistance (Durability)
    K244G-2 With Metal Case Cover 1a1b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2/2 With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2/2U With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2S With Metal Case Cover 1a1b 10 (Continuous) 24 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2S/2S With Metal Case Cover 2a2b 10 (Continuous) 24 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2U With Metal Case Cover 1a1b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2U/2U With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2V With Metal Case Cover 1a1b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244G-2V/2V With Metal Case Cover 2a2b 10 (Continuous) 26 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GO-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GO-2S/2S Oil-Tight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GOR-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GOR-2S/2S Oil-Tight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GORF-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GORL-2S Oil-Tight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GR-2/2 With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GR-2/2U With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GR-2S/2S With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - 0.3 or less (K244gR-2S) 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GR-2U With Metal Case Cover 1a1b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GR-2U/2U With Metal Case Cover 2a2b 10 (Continuous) 55 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GR-2V With Metal Case Cover 1a1b 10 (Continuous) 57 AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRF-2 With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRF-2S With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - 0.3 or less (K244gR-2S) 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRF-2U With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRF-2V With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRF-2V/2V With Metal Case Cover 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRL-2 With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRL-2S With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - 0.3 or less (K244gR-2S) 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRL-2U With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GRL-2V With Metal Case Cover 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GW-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GW-2S/2S Watertight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GWR-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GWR-2S/2S Watertight Type 2a2b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GWRF-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244GWRL-2S Watertight Type 1a1b 10 (Continuous) - AC2500V 1 min - - - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244XP-2U With Plastic Cover 1a1b 10 (Continuous) 21 AC2500V 1 min 1.5 6 - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)
    K244XP-2V With Plastic Cover 1a1b 10 (Continuous) 21 AC2500V 1 min 1 8.5 - 100 or more (DC500V megger) -5~60 200 Double Amplitude 1.5mm 10-55Hz (2 h Each in 3 Directions)

    How to Order

    Select the exact part number from the options. Fuji Electric Japanese-market part numbers encode coil voltage, ratings and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.

    About Fuji Electric

    Fuji Electric is a Japanese manufacturer of power electronics and industrial systems, producing FRENIC inverters, servo systems, MICREX PLCs, magnetic contactors and starters, G-TWIN circuit breakers and command switches used in factories, buildings and infrastructure worldwide.

    Ordering & Shipping

    • Genuine Fuji Electric product sourced through Korean distribution
    • Lead time varies by model; most items ship within 2-3 weeks
    • Ships worldwide from South Korea by FedEx International Priority Express
    • Import duties and taxes are payable by the recipient
    • Bulk and trade pricing available on request

    Recently viewed products

    Login

    Forgot your password?

    Don't have an account yet?
    Create account