IDEC Ø30 Zinc Die-Cast Series Selector Switch ASD□L Type (Lever Handle) - ASD21L10N

  • IDEC ASD21L10N Photo on request Genuine IDEC part

Description

IDEC ASD — Ø30 Zinc Die-Cast Series Selector Switch ASD□L Type (Lever Handle), genuine IDEC product.

Overview

IDEC control and signaling devices, including pushbuttons, illuminated pushbuttons, selector and key switches, pilot lights, buzzers, control boxes and maintenance parts for Ø8 to Ø30 panel mounting.

Key Features

  • Genuine IDEC control and signaling device
  • Select by mounting hole size, shape, color, contacts and LED voltage
  • Full range of guards, nameplates and replacement parts

Specifications

Part No. Number of Contacts Protection Rating Contact Configuration Terminal Type Insulation Voltage (V) Notch Angle (°) Number of Notches Operation Storage Temperature (℃) Insulation Resistance (MΩ) Operating Ambient Temperature (℃) Mounting Hole Diameter (Ømm)
ASD21L10N 1 contact IP65 1a M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD21L11N 2 contacts IP65 1a1b M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD21L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD21L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD22L10N 1 contact IP65 1a M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD22L11N 2 contacts IP65 1a1b M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD22L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD22L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD2L01N 1 contact IP65 1b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD2L11N 2 contacts IP65 1a1b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD2L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD2L20N-MAU 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD2L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD2L22N-MAU 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD31L02N 2 contacts IP65 2b M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD31L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD31L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD31L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD31L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD32L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD32L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD32L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD32L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD33L02N 2 contacts IP65 2b M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD33L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD33L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD33L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L02N 2 contacts IP65 2b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L11N-202 2 contacts IP65 1a1b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L20NG 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L22N-MAU 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L31N-207 4 contacts IP65 3a1b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
ASD3L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)

How to Order

Select the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.

About IDEC

IDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.

Ordering & Shipping

  • Genuine IDEC product sourced through Korean distribution
  • Lead time varies by model; most items ship within 2-3 weeks
  • Ships worldwide from South Korea by FedEx International Priority Express
  • Import duties and taxes are payable by the recipient
  • Bulk and trade pricing available on request
Product form

IDEC ASD — Ø30 Zinc Die-Cast Series Selector Switch ASD□L Type (Lever Handle), genuine IDEC product.OverviewIDEC control and signaling devices,... Read more

SKU: ASD21L10N

$19.99 Excl. VAT

    • Ships within 5–10 business days
    • Ships from South Korea
    • Export packing available
    • Worldwide shipping
    • Secure payments Paypal

    Description

    IDEC ASD — Ø30 Zinc Die-Cast Series Selector Switch ASD□L Type (Lever Handle), genuine IDEC product.

    Overview

    IDEC control and signaling devices, including pushbuttons, illuminated pushbuttons, selector and key switches, pilot lights, buzzers, control boxes and maintenance parts for Ø8 to Ø30 panel mounting.

    Key Features

    • Genuine IDEC control and signaling device
    • Select by mounting hole size, shape, color, contacts and LED voltage
    • Full range of guards, nameplates and replacement parts

    Specifications

    Part No. Number of Contacts Protection Rating Contact Configuration Terminal Type Insulation Voltage (V) Notch Angle (°) Number of Notches Operation Storage Temperature (℃) Insulation Resistance (MΩ) Operating Ambient Temperature (℃) Mounting Hole Diameter (Ømm)
    ASD21L10N 1 contact IP65 1a M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD21L11N 2 contacts IP65 1a1b M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD21L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD21L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD22L10N 1 contact IP65 1a M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD22L11N 2 contacts IP65 1a1b M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD22L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD22L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD2L01N 1 contact IP65 1b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD2L11N 2 contacts IP65 1a1b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD2L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD2L20N-MAU 2 contacts IP65 2a M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD2L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD2L22N-MAU 4 contacts IP65 2a2b M3.5 Screw Terminal 600 90 2 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD31L02N 2 contacts IP65 2b M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD31L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD31L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD31L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD31L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Spring Return from Right -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD32L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD32L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD32L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD32L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Spring Return from Left -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD33L02N 2 contacts IP65 2b M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD33L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD33L22N 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD33L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Two-Way Return -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L02N 2 contacts IP65 2b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L04N 4 contacts IP65 4b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L11N-202 2 contacts IP65 1a1b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L20N 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L20NG 2 contacts IP65 2a M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L22N-MAU 4 contacts IP65 2a2b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L31N-207 4 contacts IP65 3a1b M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)
    ASD3L40N 4 contacts IP65 4a M3.5 Screw Terminal 600 45 3 Maintained (Manual) -40~80 (no freezing) 100 min. (DC500V megger) -25~70 (no freezing) 30.5(0~0.5)

    How to Order

    Select the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.

    About IDEC

    IDEC Corporation is a Japanese manufacturer of industrial automation and safety products, known for its control and signaling devices (pushbuttons, pilot lights, emergency stop switches), relays, terminal blocks, circuit protectors, safety components, PLCs and operator interfaces.

    Ordering & Shipping

    • Genuine IDEC product sourced through Korean distribution
    • Lead time varies by model; most items ship within 2-3 weeks
    • Ships worldwide from South Korea by FedEx International Priority Express
    • Import duties and taxes are payable by the recipient
    • Bulk and trade pricing available on request

    Recently viewed products

    Login

    Forgot your password?

    Don't have an account yet?
    Create account