IDEC emergency stop pushbuttons and enabling switches (XA, XW, XN, X6, HW, HE series) provide safe machine stopping and operator enabling functions for machinery and control panels.
| Part No. |
Type |
Protection Rating |
Contact Configuration |
Button Shape |
Terminal Type |
Button Color |
Insulation Voltage (V) |
Operation |
Illumination Type |
Operating Ambient Temperature (℃) |
Mounting Hole Diameter (Ømm) |
Storage Temperature (℃) |
Contact Resistance (mΩ) |
Insulation Resistance (MΩ) |
| XW1E-BV401R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV401RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV401VR |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV401VRH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV402R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
|
|
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
|
-25~60 (no freezing) |
22.3(0~0.4) |
-45~80 (no freezing) |
50 max. (initial); connector type: 300 max. |
100 min. (DC500V megger) |
| XW1E-BV402RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV402VR |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV402VRH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV403R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV403RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV403VR |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV404R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV404RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV404VRH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV411R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV411RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV411VR |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV411VRH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV412R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV412RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV412VRH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV413R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV413RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV413VR |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV413VRH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV422R |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-BV422RH |
Non-Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Bright Red |
300 |
Push-Lock Pull or Turn Reset |
Non-Illuminated |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV401Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV401Q4VR |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV402Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV402Q4VR |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV403Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV403Q4VR |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV404Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV411Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV411Q4VR |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV412Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV412Q4VR |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV413Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV413Q4VR |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
PCB Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
| XW1E-LV422Q4R |
LED Illuminated |
Panel Front: IP65, IP67 (IEC 60529) |
Separate Contact Type |
Large (Ø40) |
Solder Terminal |
Red |
300 |
Push-Lock Pull or Turn Reset |
LED Illumination |
|
|
-45~80 (no freezing) |
|
100 min. (DC500V megger) |
Select the exact part number from the options. IDEC part numbers encode color, contacts, LED voltage, terminal type and options, so please check every character against your existing part or drawing. Contact us if you need help identifying a replacement.