Prices and shipping exclude import duties and taxes, which are paid by the recipient on delivery (DAP). Need a landed-cost quote before ordering? Email info@wowtoolz.com

MITSUBISHI ELECTRIC Square AC Ammeter YN Series

Description

MITSUBISHI ELECTRIC YS — Square AC Ammeter YN Series, genuine MITSUBISHI ELECTRIC product.

Overview

The Mitsubishi Electric YS-8NAA is a square panel AC ammeter that displays load current on an analog dial, used with current transformers such as 1000/5 A or 100/5 A. It is mounted on switchboards and distribution panels to monitor circuit current. Some versions have an extended scale for motor starting current.

Key Features

  • Square analog dial for panel mounting
  • Used with 5 A secondary CTs
  • Extended scale versions for motor circuits
  • Clear indication for operators

Specifications

Part No. Accessories Cover Mass (kg) Type Model Type Operating Temp. Range (˚C) Dim. A (mm) Scale (mm) Humidity (%RH) Scale Specification
YS-10NAA B 0-10-30A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
YS-10NAA B 0-100-300A 100/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-100-300A (3x extended) 100/5A (CT ratio)
YS-10NAA B 0-15-45A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
YS-10NAA B 0-20-60A 20/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended) 20/5A (CT ratio)
YS-10NAA B 0-20-60A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
YS-10NAA B 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
YS-10NAA B 0-30-90A 30/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended) 30/5A (CT ratio)
YS-10NAA B 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
YS-10NAA B 0-40-120A 40/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-40-120A (3x extended) 40/5A (CT ratio)
YS-10NAA B 0-5-15A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)
YS-10NAA B 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
YS-10NAA B 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
YS-10NAA B 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
YS-10NAA BR 0-10-30A 10/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended) 10/5A (CT ratio)
YS-10NAA BR 0-10-30A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
YS-10NAA BR 0-15-45A 15/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended) 15/5A (CT ratio)
YS-10NAA BR 0-15-45A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
YS-10NAA BR 0-150-450A 150/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-150-450A (3x extended) 150/5A (CT ratio)
YS-10NAA BR 0-20-60A 20/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended) 20/5A (CT ratio)
YS-10NAA BR 0-20-60A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
YS-10NAA BR 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
YS-10NAA BR 0-30-90A 30/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended) 30/5A (CT ratio)
YS-10NAA BR 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
YS-10NAA BR 0-5-15A 5/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended) 5/5A (CT ratio)
YS-10NAA BR 0-5-15A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)
YS-10NAA BR 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
YS-10NAA BR 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
YS-10NAA BR 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
YS-12NAA B 0-1000A 1000/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-1000A 1000/5A (CT ratio)
YS-12NAA B 0-100A 100/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-100A 100/5A (CT ratio)
YS-12NAA B 0-150A 150/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-150A 150/5A (CT ratio)
YS-12NAA B 0-200A 200/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-200A 200/5A (CT ratio)
YS-12NAA B 0-20A 20/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-20A 20/5A (CT ratio)
YS-12NAA B 0-250A 250/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-250A 250/5A (CT ratio)
YS-12NAA B 0-300A 300/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-300A 300/5A (CT ratio)
YS-12NAA B 0-30A 30/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-30A 30/5A (CT ratio)
YS-12NAA B 0-400A 400/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-400A 400/5A (CT ratio)
YS-12NAA B 0-40A 40/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-40A 40/5A (CT ratio)
YS-12NAA B 0-500A 500/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-500A 500/5A (CT ratio)
YS-12NAA B 0-50A 50/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-50A 50/5A (CT ratio)
YS-12NAA B 0-600A 600/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-600A 600/5A (CT ratio)
YS-12NAA B 0-60A 60/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-60A 60/5A (CT ratio)
YS-12NAA B 0-750A 750/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-750A 750/5A (CT ratio)
YS-12NAA B 0-75A 75/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-75A 75/5A (CT ratio)
YS-8NAA 5A 0-5A 5/5A B Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5A 5/5A (CT ratio)
YS-8NAA B 0-100-300A 100/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-100-300A (3x extended) 100/5A (CT ratio)
YS-8NAA B 0-1000A 1000/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-1000A 1000/5A (CT ratio)
YS-8NAA B 0-100A 100/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-100A 100/5A (CT ratio)
YS-8NAA B 0-10A DRCT Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10A
YS-8NAA B 0-15-45A 15/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended) 15/5A (CT ratio)
YS-8NAA B 0-150-450A 150/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-150-450A (3x extended) 150/5A (CT ratio)
YS-8NAA B 0-15A DRCT Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15A
YS-8NAA B 0-20-60A 20/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended) 20/5A (CT ratio)
YS-8NAA B 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
YS-8NAA B 0-200A 200/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-200A 200/5A (CT ratio)
YS-8NAA B 0-20A DRCT Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20A
YS-8NAA B 0-250-750A 250/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-250-750A (3x extended) 250/5A (CT ratio)
YS-8NAA B 0-250A 250/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-250A 250/5A (CT ratio)
YS-8NAA B 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
YS-8NAA B 0-300-900A 300/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-300-900A (3x extended) 300/5A (CT ratio)
YS-8NAA B 0-300A 300/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-300A 300/5A (CT ratio)
YS-8NAA B 0-30A 30/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30A 30/5A (CT ratio)
YS-8NAA B 0-40-120A 40/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-40-120A (3x extended) 40/5A (CT ratio)
YS-8NAA B 0-400-1200A 400/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-400-1200A (3x extended) 400/5A (CT ratio)
YS-8NAA B 0-400A 400/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-400A 400/5A (CT ratio)
YS-8NAA B 0-40A 40/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-40A 40/5A (CT ratio)
YS-8NAA B 0-5-15A 5/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended) 5/5A (CT ratio)
YS-8NAA B 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
YS-8NAA B 0-500A 500/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-500A 500/5A (CT ratio)
YS-8NAA B 0-50A 50/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-50A 50/5A (CT ratio)
YS-8NAA B 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
YS-8NAA B 0-600A 600/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-600A 600/5A (CT ratio)
YS-8NAA B 0-60A 60/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-60A 60/5A (CT ratio)
YS-8NAA B 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
YS-8NAA B 0-750A 750/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-750A 750/5A (CT ratio)
YS-8NAA B 0-75A 75/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-75A 75/5A (CT ratio)
YS-8NAA BR 0-10-30A 10/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended) 10/5A (CT ratio)
YS-8NAA BR 0-100-300A 100/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-100-300A (3x extended) 100/5A (CT ratio)
YS-8NAA BR 0-150-450A 150/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-150-450A (3x extended) 150/5A (CT ratio)
YS-8NAA BR 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
YS-8NAA BR 0-250-750A 250/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-250-750A (3x extended) 250/5A (CT ratio)
YS-8NAA BR 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
YS-8NAA BR 0-300-900A 300/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-300-900A (3x extended) 300/5A (CT ratio)
YS-8NAA BR 0-40-120A 40/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-40-120A (3x extended) 40/5A (CT ratio)
YS-8NAA BR 0-400-1200A 400/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-400-1200A (3x extended) 400/5A (CT ratio)
YS-8NAA BR 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
YS-8NAA BR 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
YS-8NAA BR 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
YS-8NAA G 0-10-30A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
YS-8NAA G 0-15-45A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
YS-8NAA G 0-20-60A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
YS-8NAA G 0-3-9A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-3-9A (3x extended)
YS-8NAA G 0-30-90A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
YS-8NAA G 0-5-15A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)
YS-8NAA GR 0-10-30A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
YS-8NAA GR 0-15-45A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
YS-8NAA GR 0-20-60A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
YS-8NAA GR 0-3-9A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-3-9A (3x extended)
YS-8NAA GR 0-30-90A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
YS-8NAA GR 0-5-15A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)

How to Order

Specify the scale range and CT ratio. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.

About MITSUBISHI ELECTRIC

Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.

Ordering & Shipping

  • Genuine MITSUBISHI ELECTRIC product sourced through Korean distribution
  • Ships worldwide from South Korea by FedEx International Priority Express
  • Lead time varies by model; please inquire for exact delivery
  • Import duties and taxes are payable by the recipient
  • Bulk and trade pricing available on request
Product form

MITSUBISHI ELECTRIC YS — Square AC Ammeter YN Series, genuine MITSUBISHI ELECTRIC product.OverviewThe Mitsubishi Electric YS-8NAA is a square panel... Read more

SKU: YS-10NAA B 0-10-30A DRCT N

$56.07 Excl. VAT

    • Ships within 5–10 business days
    • Ships from South Korea
    • Export packing available
    • Worldwide shipping
    • Secure payments Paypal

    Description

    MITSUBISHI ELECTRIC YS — Square AC Ammeter YN Series, genuine MITSUBISHI ELECTRIC product.

    Overview

    The Mitsubishi Electric YS-8NAA is a square panel AC ammeter that displays load current on an analog dial, used with current transformers such as 1000/5 A or 100/5 A. It is mounted on switchboards and distribution panels to monitor circuit current. Some versions have an extended scale for motor starting current.

    Key Features

    • Square analog dial for panel mounting
    • Used with 5 A secondary CTs
    • Extended scale versions for motor circuits
    • Clear indication for operators

    Specifications

    Part No. Accessories Cover Mass (kg) Type Model Type Operating Temp. Range (˚C) Dim. A (mm) Scale (mm) Humidity (%RH) Scale Specification
    YS-10NAA B 0-10-30A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
    YS-10NAA B 0-100-300A 100/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-100-300A (3x extended) 100/5A (CT ratio)
    YS-10NAA B 0-15-45A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
    YS-10NAA B 0-20-60A 20/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended) 20/5A (CT ratio)
    YS-10NAA B 0-20-60A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
    YS-10NAA B 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
    YS-10NAA B 0-30-90A 30/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended) 30/5A (CT ratio)
    YS-10NAA B 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
    YS-10NAA B 0-40-120A 40/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-40-120A (3x extended) 40/5A (CT ratio)
    YS-10NAA B 0-5-15A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)
    YS-10NAA B 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
    YS-10NAA B 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
    YS-10NAA B 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
    YS-10NAA BR 0-10-30A 10/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended) 10/5A (CT ratio)
    YS-10NAA BR 0-10-30A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
    YS-10NAA BR 0-15-45A 15/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended) 15/5A (CT ratio)
    YS-10NAA BR 0-15-45A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
    YS-10NAA BR 0-150-450A 150/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-150-450A (3x extended) 150/5A (CT ratio)
    YS-10NAA BR 0-20-60A 20/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended) 20/5A (CT ratio)
    YS-10NAA BR 0-20-60A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
    YS-10NAA BR 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
    YS-10NAA BR 0-30-90A 30/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended) 30/5A (CT ratio)
    YS-10NAA BR 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
    YS-10NAA BR 0-5-15A 5/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended) 5/5A (CT ratio)
    YS-10NAA BR 0-5-15A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 Direct YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)
    YS-10NAA BR 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
    YS-10NAA BR 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
    YS-10NAA BR 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.15 CT combined use YS-10NAA -5~50 (reference 23) 41 90 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
    YS-12NAA B 0-1000A 1000/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-1000A 1000/5A (CT ratio)
    YS-12NAA B 0-100A 100/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-100A 100/5A (CT ratio)
    YS-12NAA B 0-150A 150/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-150A 150/5A (CT ratio)
    YS-12NAA B 0-200A 200/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-200A 200/5A (CT ratio)
    YS-12NAA B 0-20A 20/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-20A 20/5A (CT ratio)
    YS-12NAA B 0-250A 250/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-250A 250/5A (CT ratio)
    YS-12NAA B 0-300A 300/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-300A 300/5A (CT ratio)
    YS-12NAA B 0-30A 30/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-30A 30/5A (CT ratio)
    YS-12NAA B 0-400A 400/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-400A 400/5A (CT ratio)
    YS-12NAA B 0-40A 40/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-40A 40/5A (CT ratio)
    YS-12NAA B 0-500A 500/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-500A 500/5A (CT ratio)
    YS-12NAA B 0-50A 50/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-50A 50/5A (CT ratio)
    YS-12NAA B 0-600A 600/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-600A 600/5A (CT ratio)
    YS-12NAA B 0-60A 60/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-60A 60/5A (CT ratio)
    YS-12NAA B 0-750A 750/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-750A 750/5A (CT ratio)
    YS-12NAA B 0-75A 75/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.3 CT combined use YS-12NAA -5~50 (reference 23) 50 100 Relative humidity 30~70 has no adverse effect on indication 0-75A 75/5A (CT ratio)
    YS-8NAA 5A 0-5A 5/5A B Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5A 5/5A (CT ratio)
    YS-8NAA B 0-100-300A 100/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-100-300A (3x extended) 100/5A (CT ratio)
    YS-8NAA B 0-1000A 1000/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-1000A 1000/5A (CT ratio)
    YS-8NAA B 0-100A 100/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-100A 100/5A (CT ratio)
    YS-8NAA B 0-10A DRCT Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10A
    YS-8NAA B 0-15-45A 15/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended) 15/5A (CT ratio)
    YS-8NAA B 0-150-450A 150/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-150-450A (3x extended) 150/5A (CT ratio)
    YS-8NAA B 0-15A DRCT Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15A
    YS-8NAA B 0-20-60A 20/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended) 20/5A (CT ratio)
    YS-8NAA B 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
    YS-8NAA B 0-200A 200/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-200A 200/5A (CT ratio)
    YS-8NAA B 0-20A DRCT Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20A
    YS-8NAA B 0-250-750A 250/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-250-750A (3x extended) 250/5A (CT ratio)
    YS-8NAA B 0-250A 250/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-250A 250/5A (CT ratio)
    YS-8NAA B 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
    YS-8NAA B 0-300-900A 300/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-300-900A (3x extended) 300/5A (CT ratio)
    YS-8NAA B 0-300A 300/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-300A 300/5A (CT ratio)
    YS-8NAA B 0-30A 30/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30A 30/5A (CT ratio)
    YS-8NAA B 0-40-120A 40/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-40-120A (3x extended) 40/5A (CT ratio)
    YS-8NAA B 0-400-1200A 400/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-400-1200A (3x extended) 400/5A (CT ratio)
    YS-8NAA B 0-400A 400/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-400A 400/5A (CT ratio)
    YS-8NAA B 0-40A 40/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-40A 40/5A (CT ratio)
    YS-8NAA B 0-5-15A 5/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended) 5/5A (CT ratio)
    YS-8NAA B 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
    YS-8NAA B 0-500A 500/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-500A 500/5A (CT ratio)
    YS-8NAA B 0-50A 50/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-50A 50/5A (CT ratio)
    YS-8NAA B 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
    YS-8NAA B 0-600A 600/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-600A 600/5A (CT ratio)
    YS-8NAA B 0-60A 60/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-60A 60/5A (CT ratio)
    YS-8NAA B 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
    YS-8NAA B 0-750A 750/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-750A 750/5A (CT ratio)
    YS-8NAA B 0-75A 75/5A Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-75A 75/5A (CT ratio)
    YS-8NAA BR 0-10-30A 10/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended) 10/5A (CT ratio)
    YS-8NAA BR 0-100-300A 100/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-100-300A (3x extended) 100/5A (CT ratio)
    YS-8NAA BR 0-150-450A 150/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-150-450A (3x extended) 150/5A (CT ratio)
    YS-8NAA BR 0-200-600A 200/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-200-600A (3x extended) 200/5A (CT ratio)
    YS-8NAA BR 0-250-750A 250/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-250-750A (3x extended) 250/5A (CT ratio)
    YS-8NAA BR 0-30-90A DRCT N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
    YS-8NAA BR 0-300-900A 300/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-300-900A (3x extended) 300/5A (CT ratio)
    YS-8NAA BR 0-40-120A 40/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-40-120A (3x extended) 40/5A (CT ratio)
    YS-8NAA BR 0-400-1200A 400/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-400-1200A (3x extended) 400/5A (CT ratio)
    YS-8NAA BR 0-50-150A 50/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-50-150A (3x extended) 50/5A (CT ratio)
    YS-8NAA BR 0-60-180A 60/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-60-180A (3x extended) 60/5A (CT ratio)
    YS-8NAA BR 0-75-225A 75/5A N Nut for mounting screw Black (Munsell N1.5 semi-gloss) 0.1 CT combined use YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-75-225A (3x extended) 75/5A (CT ratio)
    YS-8NAA G 0-10-30A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
    YS-8NAA G 0-15-45A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
    YS-8NAA G 0-20-60A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
    YS-8NAA G 0-3-9A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-3-9A (3x extended)
    YS-8NAA G 0-30-90A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
    YS-8NAA G 0-5-15A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)
    YS-8NAA GR 0-10-30A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-10-30A (3x extended)
    YS-8NAA GR 0-15-45A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-15-45A (3x extended)
    YS-8NAA GR 0-20-60A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-20-60A (3x extended)
    YS-8NAA GR 0-3-9A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-3-9A (3x extended)
    YS-8NAA GR 0-30-90A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-30-90A (3x extended)
    YS-8NAA GR 0-5-15A DRCT N Nut for mounting screw Transparent 0.1 Direct YS-8NAA -5~50 (reference 23) 41 70 Relative humidity 30~70 has no adverse effect on indication 0-5-15A (3x extended)

    How to Order

    Specify the scale range and CT ratio. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.

    About MITSUBISHI ELECTRIC

    Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.

    Ordering & Shipping

    • Genuine MITSUBISHI ELECTRIC product sourced through Korean distribution
    • Ships worldwide from South Korea by FedEx International Priority Express
    • Lead time varies by model; please inquire for exact delivery
    • Import duties and taxes are payable by the recipient
    • Bulk and trade pricing available on request

    Recently viewed products

    Login

    Forgot your password?

    Don't have an account yet?
    Create account