MITSUBISHI ELECTRIC Block-Type Remote Unit, NZ2GN2

Description

MITSUBISHI ELECTRIC NZ2GN2 — Block-Type Remote Unit, genuine MITSUBISHI ELECTRIC product.

Overview

The NZ2GN2B1-32T and NZ2GN2B1-32DT are block-type remote I/O units from Mitsubishi Electric for the CC-Link IE TSN network, providing transistor outputs (32T) or combined DC inputs and transistor outputs (32DT). Installed close to field devices, they reduce wiring back to the control panel. They are used for distributed I/O on machines and conveyors.

Key Features

  • Block-type remote I/O housing
  • Output-only or mixed input/output versions
  • Reduces wiring to the control panel
  • Connects over CC-Link IE TSN

Specifications

Part No. Withstand Voltage Rated Input Voltage (V) No. of Outputs Conversion Speed No. of Inputs Communication Speed Protection Rating Rated Input Current (A) Rated Load Voltage (V) Insulation Resistance (MΩ) Inrush Current (A) Load Current (mA) Dielectric Strength (V/1 min) Input Resistance (kΩ) Voltage Drop (V) Leakage Current (mA)
NZ2GN2B-60AD4 All power/communication circuits - all analog inputs AC510V for 1 minute 200μs/channel 1Gbps、100Mbps
NZ2GN2B-60DA4 All power/communication circuits - all analog inputs AC500V for 1 minute Number of analog outputs: 4 (4 channels) / 1 unit 200μs/channel
NZ2GN2B1-32D DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 32 32 IP2X 0.006 TYP. (at DC24V) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground Between all DC external terminals and ground AC510/1 3.3
NZ2GN2B1-32DT DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
NZ2GN2B1-32DTE DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
NZ2GN2B1-32T 32 32 IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common (Max when ON) DC0.3 (TYP.) 0.5A, DC0.6 (MAX.) 0.5A
NZ2GN2B1-32TE 32 IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 5000/1 common Between all DC external terminals and ground AC510/1 When OFF: 0.1 or less
NZ2GN2S-60AD4 All power/communication circuits - all analog inputs AC510V for 1 minute 200μs/channel 1Gbps、100Mbps
NZ2GN2S-60DA4 All power/communication circuits - all analog inputs AC500V for 1 minute Number of analog outputs: 4 (4 channels) / 1 unit 200μs/channel
NZ2GN2S1-32D DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 32 IP2X 0.006 TYP. (at DC24V) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground Between all DC external terminals and ground AC510/1 3.3
NZ2GN2S1-32DT DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
NZ2GN2S1-32DTE DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
NZ2GN2S1-32T 32 IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 5000/1 common Between all DC external terminals and ground AC510/1 When OFF: 0.1 or less
NZ2GN2S1-32TE IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 5000/1 common Between all DC external terminals and ground AC510/1 When OFF: 0.1 or less

How to Order

Confirm the network is CC-Link IE TSN and choose the I/O configuration and output type. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.

About MITSUBISHI ELECTRIC

Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.

Ordering & Shipping

  • Genuine MITSUBISHI ELECTRIC product sourced through Korean distribution
  • Ships worldwide from South Korea by FedEx International Priority Express
  • Lead time varies by model; please inquire for exact delivery
  • Import duties and taxes are payable by the recipient
  • Bulk and trade pricing available on request
Product form

MITSUBISHI ELECTRIC NZ2GN2 — Block-Type Remote Unit, genuine MITSUBISHI ELECTRIC product.OverviewThe NZ2GN2B1-32T and NZ2GN2B1-32DT are block-type remote I/O units from... Read more

SKU: NZ2GN2B-60AD4

$820.37 Excl. VAT

    • Ships within 5–10 business days
    • Ships from South Korea
    • Export packing available
    • Worldwide shipping
    • Secure payments Paypal

    Description

    MITSUBISHI ELECTRIC NZ2GN2 — Block-Type Remote Unit, genuine MITSUBISHI ELECTRIC product.

    Overview

    The NZ2GN2B1-32T and NZ2GN2B1-32DT are block-type remote I/O units from Mitsubishi Electric for the CC-Link IE TSN network, providing transistor outputs (32T) or combined DC inputs and transistor outputs (32DT). Installed close to field devices, they reduce wiring back to the control panel. They are used for distributed I/O on machines and conveyors.

    Key Features

    • Block-type remote I/O housing
    • Output-only or mixed input/output versions
    • Reduces wiring to the control panel
    • Connects over CC-Link IE TSN

    Specifications

    Part No. Withstand Voltage Rated Input Voltage (V) No. of Outputs Conversion Speed No. of Inputs Communication Speed Protection Rating Rated Input Current (A) Rated Load Voltage (V) Insulation Resistance (MΩ) Inrush Current (A) Load Current (mA) Dielectric Strength (V/1 min) Input Resistance (kΩ) Voltage Drop (V) Leakage Current (mA)
    NZ2GN2B-60AD4 All power/communication circuits - all analog inputs AC510V for 1 minute 200μs/channel 1Gbps、100Mbps
    NZ2GN2B-60DA4 All power/communication circuits - all analog inputs AC500V for 1 minute Number of analog outputs: 4 (4 channels) / 1 unit 200μs/channel
    NZ2GN2B1-32D DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 32 32 IP2X 0.006 TYP. (at DC24V) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground Between all DC external terminals and ground AC510/1 3.3
    NZ2GN2B1-32DT DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
    NZ2GN2B1-32DTE DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
    NZ2GN2B1-32T 32 32 IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common (Max when ON) DC0.3 (TYP.) 0.5A, DC0.6 (MAX.) 0.5A
    NZ2GN2B1-32TE 32 IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 5000/1 common Between all DC external terminals and ground AC510/1 When OFF: 0.1 or less
    NZ2GN2S-60AD4 All power/communication circuits - all analog inputs AC510V for 1 minute 200μs/channel 1Gbps、100Mbps
    NZ2GN2S-60DA4 All power/communication circuits - all analog inputs AC500V for 1 minute Number of analog outputs: 4 (4 channels) / 1 unit 200μs/channel
    NZ2GN2S1-32D DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 32 IP2X 0.006 TYP. (at DC24V) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground Between all DC external terminals and ground AC510/1 3.3
    NZ2GN2S1-32DT DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
    NZ2GN2S1-32DTE DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 16 16 IP2X 0.006 TYP. (at DC24V) DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 4000/1 common
    NZ2GN2S1-32T 32 IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 5000/1 common Between all DC external terminals and ground AC510/1 When OFF: 0.1 or less
    NZ2GN2S1-32TE IP2X DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) 10 or more with DC500V insulation resistance tester between all DC external terminals and ground (Max) current limited by overload protection function Max: 500/1 point, 5000/1 common Between all DC external terminals and ground AC510/1 When OFF: 0.1 or less

    How to Order

    Confirm the network is CC-Link IE TSN and choose the I/O configuration and output type. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.

    About MITSUBISHI ELECTRIC

    Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.

    Ordering & Shipping

    • Genuine MITSUBISHI ELECTRIC product sourced through Korean distribution
    • Ships worldwide from South Korea by FedEx International Priority Express
    • Lead time varies by model; please inquire for exact delivery
    • Import duties and taxes are payable by the recipient
    • Bulk and trade pricing available on request