The NZ2GN2B1-32T and NZ2GN2B1-32DT are block-type remote I/O units from Mitsubishi Electric for the CC-Link IE TSN network, providing transistor outputs (32T) or combined DC inputs and transistor outputs (32DT). Installed close to field devices, they reduce wiring back to the control panel. They are used for distributed I/O on machines and conveyors.
| Part No. |
Withstand Voltage |
Rated Input Voltage (V) |
No. of Outputs |
Conversion Speed |
No. of Inputs |
Communication Speed |
Protection Rating |
Rated Input Current (A) |
Rated Load Voltage (V) |
Insulation Resistance (MΩ) |
Inrush Current (A) |
Load Current (mA) |
Dielectric Strength (V/1 min) |
Input Resistance (kΩ) |
Voltage Drop (V) |
Leakage Current (mA) |
| NZ2GN2B-60AD4 |
All power/communication circuits - all analog inputs AC510V for 1 minute |
|
|
200μs/channel |
|
1Gbps、100Mbps |
|
|
|
|
|
|
|
|
|
|
| NZ2GN2B-60DA4 |
All power/communication circuits - all analog inputs AC500V for 1 minute |
|
Number of analog outputs: 4 (4 channels) / 1 unit |
200μs/channel |
|
|
|
|
|
|
|
|
|
|
|
|
| NZ2GN2B1-32D |
|
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
32 |
|
32 |
|
IP2X |
0.006 TYP. (at DC24V) |
|
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
|
|
Between all DC external terminals and ground AC510/1 |
3.3 |
|
|
| NZ2GN2B1-32DT |
|
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
16 |
|
16 |
|
IP2X |
0.006 TYP. (at DC24V) |
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 4000/1 common |
|
|
|
|
| NZ2GN2B1-32DTE |
|
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
16 |
|
16 |
|
IP2X |
0.006 TYP. (at DC24V) |
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 4000/1 common |
|
|
|
|
| NZ2GN2B1-32T |
|
|
32 |
|
32 |
|
IP2X |
|
DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 4000/1 common |
|
|
(Max when ON) DC0.3 (TYP.) 0.5A, DC0.6 (MAX.) 0.5A |
|
| NZ2GN2B1-32TE |
|
|
32 |
|
|
|
IP2X |
|
DC12/24 (ripple 5% or less) (allowable voltage range DC10.4~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 5000/1 common |
Between all DC external terminals and ground AC510/1 |
|
|
When OFF: 0.1 or less |
| NZ2GN2S-60AD4 |
All power/communication circuits - all analog inputs AC510V for 1 minute |
|
|
200μs/channel |
|
1Gbps、100Mbps |
|
|
|
|
|
|
|
|
|
|
| NZ2GN2S-60DA4 |
All power/communication circuits - all analog inputs AC500V for 1 minute |
|
Number of analog outputs: 4 (4 channels) / 1 unit |
200μs/channel |
|
|
|
|
|
|
|
|
|
|
|
|
| NZ2GN2S1-32D |
|
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
|
|
32 |
|
IP2X |
0.006 TYP. (at DC24V) |
|
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
|
|
Between all DC external terminals and ground AC510/1 |
3.3 |
|
|
| NZ2GN2S1-32DT |
|
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
16 |
|
16 |
|
IP2X |
0.006 TYP. (at DC24V) |
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 4000/1 common |
|
|
|
|
| NZ2GN2S1-32DTE |
|
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
16 |
|
16 |
|
IP2X |
0.006 TYP. (at DC24V) |
DC24 (ripple 5% or less) (allowable voltage range DC20.4~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 4000/1 common |
|
|
|
|
| NZ2GN2S1-32T |
|
|
32 |
|
|
|
IP2X |
|
DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 5000/1 common |
Between all DC external terminals and ground AC510/1 |
|
|
When OFF: 0.1 or less |
| NZ2GN2S1-32TE |
|
|
|
|
|
|
IP2X |
|
DC12/24 (ripple 5% or less) (allowable voltage range DC10.2~28.8) |
10 or more with DC500V insulation resistance tester between all DC external terminals and ground |
(Max) current limited by overload protection function |
Max: 500/1 point, 5000/1 common |
Between all DC external terminals and ground AC510/1 |
|
|
When OFF: 0.1 or less |
Confirm the network is CC-Link IE TSN and choose the I/O configuration and output type. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.
Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.