MITSUBISHI ELECTRIC Circuit Protector CP-30BA Series, CP30-BA - CP30-BA 2P 1-I 10A A

Description

MITSUBISHI ELECTRIC CP30-BA — Circuit Protector CP-30BA Series, genuine MITSUBISHI ELECTRIC product.

Overview

The CP-30BA is a circuit protector from Mitsubishi Electric for protecting control circuits and small loads against overcurrent. It is compact and mounts on DIN rail, with ratings from fractions of an ampere. It is used in control panels for PLC power, sensors and small equipment.

Key Features

  • Compact protection for control circuits
  • Low current ratings available
  • DIN rail mounting
  • Trip indication on handle

Specifications

Part No. Mass (g) Mounting Method No. of Poles Temp. Range (℃) Rated Voltage (V) Insulation Voltage (V) Rated Current (A) Humidity (%RH) Operating Characteristics Insulation Resistance (MΩ) Mechanical Durability Electrical Durability
CP30-BA 2P 1-I 10A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-I 15A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 15 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-I 20A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 20 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-I 30A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 30 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-I 5A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-S 10A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Low-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-S 3A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Low-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 1-S 5A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Low-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-I 1A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 1 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-I 2A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 2 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-I 3A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 0.5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 0.5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 10A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 15A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 15 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 1A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 1 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 20A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 20 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 2A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 2 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 30A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 30 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 3A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 2-M 7A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 7 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 0.5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 0.5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 10A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 15A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 15 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 1A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 1 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 20A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 20 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 2A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 2 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 3A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 2P 9-M 7A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 7 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 10A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 10 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 15A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 15 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 1A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 1 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 20A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 20 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 2A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 2 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 30A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 30 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 3A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 3 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 5A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 5 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
CP30-BA 3P 1-MD 7A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 7 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute

How to Order

Select number of poles, rated current and trip characteristic. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.

Product image is representative of the MITSUBISHI ELECTRIC series; appearance varies by size and model.

About MITSUBISHI ELECTRIC

Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.

Ordering & Shipping

  • Genuine MITSUBISHI ELECTRIC product sourced through Korean distribution
  • Ships worldwide from South Korea by FedEx International Priority Express
  • Lead time varies by model; please inquire for exact delivery
  • Import duties and taxes are payable by the recipient
  • Bulk and trade pricing available on request
Product form

MITSUBISHI ELECTRIC CP30-BA — Circuit Protector CP-30BA Series, genuine MITSUBISHI ELECTRIC product.OverviewThe CP-30BA is a circuit protector from Mitsubishi Electric... Read more

SKU: CP30-BA 2P 1-I 10A A

$62.30 Excl. VAT

    • Ships within 5–10 business days
    • Ships from South Korea
    • Export packing available
    • Worldwide shipping
    • Secure payments Paypal

    Description

    MITSUBISHI ELECTRIC CP30-BA — Circuit Protector CP-30BA Series, genuine MITSUBISHI ELECTRIC product.

    Overview

    The CP-30BA is a circuit protector from Mitsubishi Electric for protecting control circuits and small loads against overcurrent. It is compact and mounts on DIN rail, with ratings from fractions of an ampere. It is used in control panels for PLC power, sensors and small equipment.

    Key Features

    • Compact protection for control circuits
    • Low current ratings available
    • DIN rail mounting
    • Trip indication on handle

    Specifications

    Part No. Mass (g) Mounting Method No. of Poles Temp. Range (℃) Rated Voltage (V) Insulation Voltage (V) Rated Current (A) Humidity (%RH) Operating Characteristics Insulation Resistance (MΩ) Mechanical Durability Electrical Durability
    CP30-BA 2P 1-I 10A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-I 15A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 15 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-I 20A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 20 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-I 30A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 30 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-I 5A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-S 10A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Low-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-S 3A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Low-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 1-S 5A A 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Low-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-I 1A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 1 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-I 2A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 2 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-I 3A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Momentary type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 0.5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 0.5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 10A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 15A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 15 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 1A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 1 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 20A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 20 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 2A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 2 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 30A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 30 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 3A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 2-M 7A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 7 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 0.5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 0.5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 10A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 10 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 15A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 15 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 1A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 1 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 20A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 20 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 2A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 2 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 3A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 3 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 5A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 5 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 2P 9-M 7A B 160 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 2 -10~60 【UL 1077/CSA C22.2/No.235】AC250/DC125 250 7 85 or less Medium-speed type 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 10A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 10 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 15A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 15 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 1A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 1 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 20A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 20 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 2A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 2 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 30A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 30 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 3A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 3 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 5A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 5 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute
    CP30-BA 3P 1-MD 7A A 230 Surface mounting, IEC 35mm rail mounting, flush bracket mounting 3 -10~60 【UL 1077/CSA C22.2/No.235】AC250 250 7 85 or less Medium-speed type with inertial delay 100 or more (500V insulation resistance tester) 10,000 operations or more at 10 operations per minute without current 6,000 operations or more at rated current under rated voltage at 10 operations per minute

    How to Order

    Select number of poles, rated current and trip characteristic. Please confirm the full part number and options against the MITSUBISHI ELECTRIC catalog; contact us if you need help identifying the right model.

    Product image is representative of the MITSUBISHI ELECTRIC series; appearance varies by size and model.

    About MITSUBISHI ELECTRIC

    Mitsubishi Electric is a Japanese manufacturer of factory automation and low-voltage power distribution equipment, including MELSEC PLCs, servo systems, inverters, magnetic contactors and starters, circuit breakers and measuring instruments.

    Ordering & Shipping

    • Genuine MITSUBISHI ELECTRIC product sourced through Korean distribution
    • Ships worldwide from South Korea by FedEx International Priority Express
    • Lead time varies by model; please inquire for exact delivery
    • Import duties and taxes are payable by the recipient