  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT12-4DO-I

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT12-4DO-I

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 26 g (≈ 38 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-10DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-10DO

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR30-10DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR30-10DP

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-10DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-10DP

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 210 g (≈ 247 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-2DP2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-2DP2

    Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 54 g (≈ 66 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL18-8AO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL18-8AO

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRWL08-2DP

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRWL08-2DP

    Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 34 g (≈ 46 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRW30-10DN

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW30-10DN

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 122 g (≈ 134 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT30-15DO

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT30-15DO

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 142 g (≈ 154 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML18-5DN2

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML18-5DN2

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 73 g (≈ 85 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM18-8DP

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM18-8DP

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 49 g (≈ 61 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDLT18-14DC

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDLT18-14DC

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT30-15DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT30-15DO

    Installation Flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL30-15DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL30-15DN

    Installation Flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 100Hz Unit weight (packaged weight) ≈ 183 g (≈ 220 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD30-25DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD30-25DN2

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 25mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 75×75×1mm(iron) Response frequency 100Hz Unit weight (packaged weight) ≈ 143 g (≈ 180 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDWT18-7DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDWT18-7DO

    Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 20×20×1mm(iron) Response frequency 250Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 62g (≈ 80g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW12-4DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW12-4DN2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Unit weight (packaged weight) ≈ 37 g (≈ 67 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCML18-7DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCML18-7DN

    Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 20×20×1mm(iron) Response frequency 300Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 60g (≈ 78g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PS12-4DN2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PS12-4DN2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 12mm Sensing distance 4mm Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight Approx. 77g(approx. 62g)

  • Autonics Proximity Sensor  Long-Range Proximity Sensor DC 3-Wire PRD08-2DN

    Autonics Autonics Proximity Sensor Long-Range Proximity Sensor DC 3-Wire PRD08-2DN

    Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 43 g (≈ 63 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM30-12DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor IO LINK PRFDCM30-12DN

    Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 85 g (≈ 140 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW12-3DN-V

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRFDW12-3DN-V

    Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 80Hz Indicator Operation indicator (orange), stable indicator (green), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 35 g (≈ 60 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,000 VAC~ 50 / 60 Hz for 1 minute (between all terminals and case) Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)

  • Autonics Proximity Sensor  Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM18-7DP-K

    Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM18-7DP-K

    Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 32 g (≈ 67 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)

    $146.85

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-15DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-15DP

    nstallation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 210 g (≈ 247 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DN2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DN2

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-8DP2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-8DP2

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR08-1.5DP2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR08-1.5DP2

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DN2

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DN2

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT18-8DC

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT18-8DC

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 49 g (≈ 61 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-2DN2

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-2DN2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 26 g (≈ 38 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-4DN2

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-4DN2

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 26 g (≈ 38 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-4DP2

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-4DP2

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 26 g (≈ 38 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT30-25DC

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT30-25DC

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 25mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 75×75×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-4DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-4DN2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Unit weight (packaged weight) ≈ 62 g (≈ 74 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL12-4DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL12-4DN2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Unit weight (packaged weight) ≈ 82 g (≈ 94 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW12-4DP2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW12-4DP2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Unit weight (packaged weight) ≈ 37 g (≈ 67 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDCMT12-8DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDCMT12-8DO

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 50g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PS12-4DN

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PS12-4DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 12mm Sensing distance 4mm Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight Approx. 77g(approx. 62g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN17-5DNU

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN17-5DNU

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 5mm Standard sensing target 18×18×1mm(iron) Response frequency 700Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Upper sensing type Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRFDWT18-7DO-IV

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRFDWT18-7DO-IV

    Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Stability indicator (green), operation indicator (red) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (dark gray): oil resistant polyvinyl chloride (PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-5DC

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-5DC

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-8DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-8DN2

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Unit weight (packaged weight) ≈ 62 g (≈ 74 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL18-14DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL18-14DN

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Unit weight (packaged weight) ≈ 127 g (≈ 145 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-4DP2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-4DP2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 49g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCML12-4DP2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCML12-4DP2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 24g (≈ 54g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-8DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-8DN2

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 49g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN17-8DP2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN17-8DP2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 8mm Standard sensing target 25×25×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output PNP Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PS50-30DN2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PS50-30DN2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 50mm Sensing distance 30mm Standard sensing target 90×90×1mm(iron) Response frequency 50Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 220g (≈ 256g)