Electrical & Automation

2211 products


  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCML18-14DP

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCML18-14DP

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 60g (≈ 78g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor AC 2-Wire PSN40-20AO

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor AC 2-Wire PSN40-20AO

    Wire type and power AC 2-wire type100-240VAC~ Sensing side size Frame size 40mm Sensing distance 20mm Standard sensing target 60×60×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.5mA Control output Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 130g (≈ 219g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN17-5DN2U

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN17-5DN2U

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 5mm Standard sensing target 18×18×1mm(iron) Response frequency 700Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Upper sensing type Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Cylindrical Capacitive Proximity Sensor AC 2-Wire CR30-15AC

    Autonics Autonics Proximity Sensor Cylindrical Capacitive Proximity Sensor AC 2-Wire CR30-15AC

    Wire type and power AC 2-wire type100-240VAC~ Sensing side diameter M30 Sensing distance 15mm Standard sensing target 50×50×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.2mA Control output Normally Closed Material Brass(nickel plated) Protection structure IP65 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 20% of sensing distance Weight ≈ 200g (≈ 237g)

  • Autonics Proximity Sensor  Square Type Long-Range Proximity Sensor DC4 AS80-50DN3

    Autonics Autonics Proximity Sensor Square Type Long-Range Proximity Sensor DC4 AS80-50DN3

    Wire type and power DC 4-wire type12-48VDC  Sensing side size Frame size 80mm Sensing distance 50mm Standard sensing target 150×150×1mm(iron) Response frequency 30Hz Current specification Current consumption: Max. 20mA Control output NPN Normally Open+Normally Closed Sensing type Upper sensing type Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 15% of sensing distance Weight Approx. 470g

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PS08-2.5DN2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PS08-2.5DN2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 8mm Sensing distance 2.5mm Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Standard type(front sensing type) Material Polycarbonate Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 20% at sensing distance Weight ≈ 16 g (≈ 30 g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-10DN2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-10DN2

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 210 g (≈ 247 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL30-15AO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PRL30-15AO

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 208 g (≈ 245 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML30-15DP

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML30-15DP

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 169 g (≈ 181 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-8DC

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-8DC

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 62g (≈ 74g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-14DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-14DN2

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Unit weight (packaged weight) ≈ 97 g (≈ 115 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor AC 2-Wire PSN30-10AO

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor AC 2-Wire PSN30-10AO

    Wire type and power AC 2-wire type100-240VAC~ Sensing side size Frame size 30mm Sensing distance 10mm Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.5mA Control output Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 92g (≈ 161g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN17-8DP

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN17-8DP

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 8mm Standard sensing target 25×25×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output PNP Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-8DP2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-8DP2

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-10AO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-10AO

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-15AC

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR30-15AC

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-2DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-2DN

    Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 26 g (≈ 38 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML30-15DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML30-15DN

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 169 g (≈ 181 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor AC 2-Wire PRCM18-8AO

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor AC 2-Wire PRCM18-8AO

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 54 g (≈ 66 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDWT30-25DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDWT30-25DO

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 25mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 75×75×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130g (≈ 145g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-4DN2

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-4DN2

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 49g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-8DN2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-8DN2

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRW08-2DN

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-2DN

    Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM30-10DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM30-10DN

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 134 g (≈ 146 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-4DC

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-4DC

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 450Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 62g (≈ 74g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN17-8DN2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN17-8DN2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 8mm Standard sensing target 25×25×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN25-5DN

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN25-5DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 25mm Sensing distance 5mm Standard sensing target 25×25×1mm(iron) Response frequency 300Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 71g (≈103g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN30-15DN2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN30-15DN2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 30mm Sensing distance 15mm Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 96g (≈165g)

  • Autonics Proximity Sensor  Cylindrical Capacitive Proximity Sensor DC 3-Wire CR30-15DP

    Autonics Autonics Proximity Sensor Cylindrical Capacitive Proximity Sensor DC 3-Wire CR30-15DP

    Wire type and power DC 3-wire type 12-24VDC  Sensing side diameter M30 Sensing distance 15mm Standard sensing target 50×50×1mm(iron) Response frequency 50Hz Current specification Current consumption: Max.15mA Control output PNP Normally Open Material Brass(nickel plated) Protection structure IP65 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 20% of sensing distance Weight ≈ 206g (≈ 243g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-1.5DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-1.5DN

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 54 g (≈ 66 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-2DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-2DP

    Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 54 g (≈ 66 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 2-Wire PRWT18-8DO

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT18-8DO

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRW18-8DN2

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW18-8DN2

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML30-10DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCML30-10DN

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 169 g (≈ 181 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT30-25DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT30-25DO

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 25mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 75×75×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW18-14DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW18-14DN

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 62g (≈ 80g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-8DP

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-8DP

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 49g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-2DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL08-2DN

    Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 54 g (≈ 66 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT18-5DO

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT18-5DO

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 49 g (≈ 61 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-4DP

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-4DP

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 49g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor AC 2-Wire PSN40-20AC

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor AC 2-Wire PSN40-20AC

    Wire type and power AC 2-wire type100-240VAC~ Sensing side size Frame size 40mm Sensing distance 20mm Standard sensing target 60×60×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.5mA Control output Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 130g (≈ 219g)

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN40-20DN2

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN40-20DN2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 40mm Sensing distance 20mm Standard sensing target 60×60×1mm(iron) Response frequency 100Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 135g (≈225g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-5DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-5DN

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR12-4DN2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR12-4DN2

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical  Proximity Sensor DC 2-Wire PRWT08-1.5DO

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT08-1.5DO

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 2-Wire PRWT18-8DC

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT18-8DC

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DP

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DP

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT18-8DO

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 2-Wire PRCMT18-8DO

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 49 g (≈ 61 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

Login

Forgot your password?

Don't have an account yet?
Create account