  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM30-15DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM30-15DN

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 134 g (≈ 146 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR30-10DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR30-10DN

    Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR12-2DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR12-2DP

    Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT08-2DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT08-2DO

    Installation Flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 43 g (≈ 63 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor AC 2-Wire PR18-5AO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor AC 2-Wire PR18-5AO

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 20Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 118 g (≈ 130 g) Power voltage 100 - 240 VAC~ 50 / 60 Hz, operating voltage: 85 - 264 VAC~ Current specification Leakage current: Max. 2.5mA Control output 5 to 200 mA Residual voltage Max. 10V Protection circuit Surge protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Insulation type Double insulation or reinforced insulation(mark: , dielectric strength between the measuring input part and the power part: 1kV) Dielectric strength 2,500 VAC~ 50/60 Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass, washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-8DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-8DP

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type  DC 3-Wire PSN30-15DP2

    Autonics Autonics Proximity Sensor Square Type DC 3-Wire PSN30-15DP2

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 30mm Sensing distance 15mm Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output PNP Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 96g (≈165g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-15DC

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-15DC

    stallation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-7DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-7DN

    Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 20×20×1mm(iron) Response frequency 300Hz Unit weight (packaged weight) ≈ 97 g (≈ 115 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Flat Proximity Sensor AC 2-Wire PFI25-8AO

    Autonics Autonics Proximity Sensor Square Type Flat Proximity Sensor AC 2-Wire PFI25-8AO

    Wire type and power AC 2-wire type100-240VAC~ Sensing side size Frame size 25mm Sensing distance 8mm Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.5mA Control output Normally Open Sensing type Upper sensing type Material Poly Phenylene Sulfide Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Residual voltage Max. 10V Weight Approx. 70g

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DP2

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DP2

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN30-10DN

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN30-10DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 30mm Sensing distance 10mm Standard sensing target 30×30×1mm(iron) Response frequency 250Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 96g (≈165g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-8DC

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-8DC

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-15DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL30-15DN

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 210 g (≈ 247 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PS50-30DN

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PS50-30DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 50mm Sensing distance 30mm Standard sensing target 90×90×1mm(iron) Response frequency 50Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67(IEC standard) Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 220g (≈ 256g)

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL12-8DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDL12-8DN

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Unit weight (packaged weight) ≈ 82 g (≈ 94 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Capacitive Proximity Sensor DC 3-Wire CR18-8DN

    Autonics Autonics Proximity Sensor Cylindrical Capacitive Proximity Sensor DC 3-Wire CR18-8DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side diameter M18 Sensing distance 8mm Standard sensing target 50×50×1mm(iron) Response frequency 50Hz Current specification Current consumption: Max.15mA Control output NPN Normally Open Material Polyamide 6 Protection structure IP66 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 20% of sensing distance Weight ≈ 76g (≈ 88g)

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM18-5DP

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM18-5DP

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 49 g (≈ 61 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-8DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-8DO

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 62g (≈ 74g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-14DP

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-14DP

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Unit weight (packaged weight) ≈ 97 g (≈ 115 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW12-4DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDW12-4DN

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Unit weight (packaged weight) ≈ 37 g (≈ 67 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-2DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-2DO

    Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire 2m Cable PRT12-4DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire 2m Cable PRT12-4DO

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DP

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DP

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DN

    Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DN

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT12-2DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT12-2DO

    Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72 g (≈ 84 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM18-8DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM18-8DN

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 49 g (≈ 61 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM18-14DP

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM18-14DP

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 41g (≈ 81g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 2-Wire PSNT17-5DO

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 2-Wire PSNT17-5DO

    Wire type and power DC 2-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 5mm Standard sensing target 18×18×1mm(iron) Response frequency 700Hz Current specification Leakage current: Max. 0.6mA Control output Normally Open Sensing type Standard type(front sensing type) Material Polybutylene terephthalate Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 58g (≈ 79g)

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDLT12-8DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDLT12-8DO

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor AC 2-Wire PSN25-5AO

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor AC 2-Wire PSN25-5AO

    Wire type and power AC 2-wire type100-240VAC~ Sensing side size Frame size 25mm Sensing distance 5mm Standard sensing target 25×25×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.5mA Control output Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 66g (≈ 98g)

  • Autonics Proximity Sensor  Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-4DN

    Autonics Autonics Proximity Sensor Cylindrical Connector Type Proximity Sensor DC 3-Wire PRCM12-4DN

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 26 g (≈ 38 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor AC 2-Wire PSN30-15AC

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor AC 2-Wire PSN30-15AC

    Wire type and power AC 2-wire type100-240VAC~ Sensing side size Frame size 30mm Sensing distance 15mm Standard sensing target 45×45×1mm(iron) Response frequency 20Hz Current specification Leakage current: Max. 2.5mA Control output Normally Closed Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 92g (≈ 161g)

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-8DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRDCM12-8DN

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 20g (≈ 49g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Connector models Connector type M12 Connector Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL12-4DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL12-4DN

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 76 g (≈ 88 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN30-15DN

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN30-15DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 30mm Sensing distance 15mm Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 96g (≈165g)

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-4DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-4DN

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Unit weight (packaged weight) ≈ 62 g (≈ 74 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire 5m PSN17-8DN

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire 5m PSN17-8DN

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 8mm Standard sensing target 25×25×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Standard type(front sensing type) Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-1.5DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT08-1.5DO

    Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 52 g (≈ 64 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-14DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD18-14DN

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 14mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 40×40×1mm(iron) Response frequency 200Hz Unit weight (packaged weight) ≈ 97 g (≈ 115 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR30-15DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR30-15DN

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/N

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-5DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT18-5DO

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-4DO

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 2-Wire PRDT12-4DO

    Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 450Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 62g (≈ 74g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-8DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PRL18-8DN

    Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 130 g (≈ 142 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DN

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 3-Wire PR18-5DN

    Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 110 g (≈ 122 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Square Type Proximity Sensor DC 3-Wire PSN17-8DNU

    Autonics Autonics Proximity Sensor Square Type Proximity Sensor DC 3-Wire PSN17-8DNU

    Wire type and power DC 3-wire type 12-24VDC  Sensing side size Frame size 17mm Sensing distance 8mm Standard sensing target 25×25×1mm(iron) Response frequency 200Hz Current specification Current consumption: Max. 10mA Control output NPN Normally Open Sensing type Upper sensing type Material Heat-resistant ABS Protection structure IP67 Environment_Ambient temperature -25 to 70℃, storage: -30 to 80℃ Environment_Ambient humidity 35 to 95% RH, storage: 35 to 95% RH Hysteresis(distance) Max. 10% of sensing distance Weight ≈ 62g (≈ 83g)

  • Autonics Proximity Sensor  Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-15DO

    Autonics Autonics Proximity Sensor Cylindrical Cable Type Proximity Sensor DC 2-Wire PRT30-15DO

    Installation Non-flush Sensing side diameter Ø30mm Sensing distance 15mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 45×45×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 207 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT

  • Autonics Proximity Sensor  Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-8DN

    Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor DC 3-Wire PRD12-8DN

    Installation Non-flush Sensing side diameter Ø12mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 400Hz Unit weight (packaged weight) ≈ 62 g (≈ 74 g) Indicator Operation indicator (red LED) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT