Electrical, Automation & Cables
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN403c 350A
General Product code 0164000700 Product description ABN403c 350A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 350 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-51 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$240.13
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN403c 300A
General Product code 0164000600 Product description ABN403c 300A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 300 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-51 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$240.13
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN403c 250A
General Product code 0164000500 Product description ABN403c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-51 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 140 mm Height 257 mm Depth 109 mm Weight 6.2 kg Packing Width 160 mm Height 268 mm Depth 165 mm Weight 6.5 kg Quantity (in a box) 1 pcs.
$240.13
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN404c 400A
General Product code 0164001200 Product description ABN404c 400A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 400 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-52 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$288.20
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN404c 350A
General Product code 0164001100 Product description ABN404c 350A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 350 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-52 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$288.20
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN404c 300A
General Product code 0164001000 Product description ABN404c 300A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 300 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-52 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$288.20
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN404c 250A
General Product code 0164000900 Product description ABN404c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 4000 cycles Electrical durability (AC) 1000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 42 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 5 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 88.2 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 7.5 kA at 690 V AC 50/60 Hz, IEC 60947-52 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 184 mm Height 257 mm Depth 109 mm Weight 7.8 kg Packing Width 200 mm Height 268 mm Depth 165 mm Weight 8.4 kg Quantity (in a box) 1 pcs.
$288.20
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN802c 800A
General Product code 0166000200 Product description ABN802c 800A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 800 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-62 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$553.96
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN802c 700A
General Product code 0166000100 Product description ABN802c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-62 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$553.96
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN802c 630A
General Product code 0166002200 Product description ABN802c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-62 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$553.96
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN802c 500A
General Product code 0166002100 Product description ABN802c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 10 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-62 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 7.7 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 7.7 kg Quantity (in a box) 1 pcs.
$553.96
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 800A
General Product code 0166000400 Product description ABN803c 800A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 800 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$675.51
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 700A
General Product code 0166000300 Product description ABN803c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$675.51
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 630A
General Product code 0166002400 Product description ABN803c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$675.51
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 500A
General Product code 0166002300 Product description ABN803c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.
$675.51
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 800A
General Product code 0166000600 Product description ABN804c 800A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 800 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$789.69
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 700A
General Product code 0166000500 Product description ABN804c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$789.69
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 630A
General Product code 0166002600 Product description ABN804c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$789.69
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 500A
General Product code 0166002500 Product description ABN804c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.
$789.69
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 250A
General Product code 0137005900 Product description ABN203c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 225A
General Product code 0137005800 Product description ABN203c 225A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 225 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 200A
General Product code 0137005700 Product description ABN203c 200A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 200 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 175A
General Product code 0137005600 Product description ABN203c 175A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 175 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 150A
General Product code 0137005500 Product description ABN203c 150A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 150 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 125A
General Product code 0137005400 Product description ABN203c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 100A
General Product code 0137005300 Product description ABN203c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.
$137.83
Schneider Electric Schneider Electric circuit breaker Easypact EZC100H - TMD - 50 A - 3 poles 3d EZC100H3050
Description EasyPact EZC100H is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 30kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 50A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100H is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100H Circuit breaker name Easypact EZC100H Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 50 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-250 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-250 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 50 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards JIS C8201-2-2EN/IEC 60947-1GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.0 cm Package 1 Width 8.5 cm Package 1 Length 14.0 cm Package 1 Weight 785.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.774 kg Unit Type of Package 3 P12 Number of Units in Package 3 192 Package 3 Height 50.0 cm Package 3 Width 80.0 cm Package 3 Length 120.0 cm Package 3 Weight 172.376 kg
$30.80
Schneider Electric Schneider Electric circuit breaker,EasyPact EZC100F ,TMD, 16A ,3 poles 3d EZC100F3016
Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 16A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 16 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 2.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 16 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60947 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards EN/IEC 60947-1JIS C8201-2-2GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to EN 50102 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 14.0 cm Package 1 Length 8.0 cm Package 1 Weight 792.0 g
$20.90
Schneider Electric Schneider Electric circuit breaker Easypact EZC100H - TMD - 30 A - 3 poles 3d EZC100H3030
Description EasyPact EZC100H is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 30kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 30A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100H is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100H Circuit breaker name Easypact EZC100H Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 30 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-250 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-250 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 30 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards JIS C8201-2-2EN/IEC 60947-1GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14 cm Package 1 Weight 790 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 9.935 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 328 kg
$25.30
Schneider Electric Schneider Electric circuit breaker Easypact EZC100H - TMD - 100 A - 3 poles 3d EZC100H3100
Description EasyPact EZC100H is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 30kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 100A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100H is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100H Circuit breaker name Easypact EZC100H Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 100 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-250 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-250 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 100 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards GB/T 14048.2JIS C8201-2-2EN/IEC 60947-1EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14.0 cm Package 1 Weight 839.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 10.12 kg Unit Type of Package 3 P12 Number of Units in Package 3 192 Package 3 Height 80.0 cm Package 3 Width 80.0 cm Package 3 Length 120.0 cm Package 3 Weight 175.568 kg
$34.10
Schneider Electric Schneider Electric circuit breaker Easypact EZC100F - TMD - 50 A - 3 poles 3d EZC100F3050
Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 50A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 50 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 50 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards EN/IEC 60947-1GB/T 14048.2JIS C8201-2-2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.4 cm Package 1 Width 8.2 cm Package 1 Length 14.0 cm Package 1 Weight 758.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.496 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 120 cm Package 3 Length 80 cm Package 3 Weight 317 kg
$35.31
Schneider Electric Schneider Electric circuit breaker Easypact EZC100H - TMD - 60 A - 3 poles 3d EZC100H3060
Description EasyPact EZC100H is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 30kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 60A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100H is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100H Circuit breaker name Easypact EZC100H Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 60 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-250 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-250 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 60 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards GB/T 14048.2EN/IEC 60947-2EN/IEC 60947-1JIS C8201-2-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14.0 cm Package 1 Weight 843.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 10.153 kg Unit Type of Package 3 P12 Number of Units in Package 3 192 Package 3 Height 80.0 cm Package 3 Width 80.0 cm Package 3 Length 120.0 cm Package 3 Weight 175.184 kg
$30.80
Schneider Electric Schneider Electric circuit breaker Easypact EZC100F - TMD - 15 A - 3 poles 3d EZC100F3015
Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 15A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 15 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 15 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards JIS C8201-2-2EN/IEC 60947-1GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.2 cm Package 1 Length 14.0 cm Package 1 Weight 817.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.892 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 120 cm Package 3 Length 80 cm Package 3 Weight 330 kg
$29.22
Schneider Electric Schneider Electric circuit breaker Easypact EZC250H - TMD - 200 A - 3 poles 3d EZC250H3200
Description This is a 200A circuit breaker for EasyPact EZC250H. This product can work below rated operational voltage(Ue) 550VAC at 50/60Hz or 250VDC network. The ultimate breaking capacity(Icu) is shown differently, depended on the condition of network, Ics=50%Icu if need to match. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 105mm(width),165mm(height),60mm(Depth). Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250H Circuit breaker name Easypact EZC250H Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 200 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 125 V DC 1P conforming to IEC 60947-230 kA Icu at 250 V DC 2P conforming to IEC 60947-236 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-215 kA at 125 V DC conforming to IEC 60947-215 kA at 250 V DC conforming to IEC 60947-218 kA at 380 V AC 50/60 Hz conforming to IEC 60947-218 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-242.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-242.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 200 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards EN/IEC 60947-1GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 10.600 cm Package 1 Width 11.600 cm Package 1 Length 18.200 cm Package 1 Weight 1.588 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30.000 cm Package 2 Width 30.000 cm Package 2 Length 40.000 cm Package 2 Weight 13.623 kg Unit Type of Package 3 P12 Number of Units in Package 3 64 Package 3 Height 50.000 cm Package 3 Width 80.000 cm Package 3 Length 120.000 cm Package 3 Weight 120.984 kg
$121.00
Schneider Electric Schneider Electric circuit breaker, Easypact EZC400H, TMD, 400A, 3 poles 3d EZC400H3400N
Description This is a 400A circuit breaker for EasyPact EZC400H. This product can work below rated operational voltage(Ue) 440VAC at 50/60Hz. The ultimate breaking capacity(Icu) is 50kA at 440V, in terms of complete range Ics=100%Icu(Ics= 50%Icu at 440V. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 140mm(width),255mm(height),110mm(Depth). Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC400H Circuit breaker name Easypact EZC400H Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 400 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 250 V DC conforming to IEC 60947-2440 V AC 50/60 Hz conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-225 kA at 440 V AC 50/60 Hz conforming to IEC 60947-235 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 400 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60947 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 45 mm local signalling Positive contact indication Contact position indicator Yes Magnetic tripping current 4000 A Neutral protection setting Without protection Long time pick-up adjustment type Ir Fixed Long time delay adjustment type Fixed earth-leakage protection Without height 255 mm Width 185 mm Depth 140 mm Net weight 6.4 kg Quantity per set 1 piece Colour Black Environment Standards JIS C8201-2-2EN/IEC 60947-2GB/T 14048.2EN/IEC 60947-1 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to EN 50102 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 15.0 cm Package 1 Width 16.0 cm Package 1 Length 29.0 cm Package 1 Weight 5.319 kg Unit Type of Package 2 S04 Number of Units in Package 2 3 Package 2 Height 30.0 cm Package 2 Width 40.0 cm Package 2 Length 60.0 cm Package 2 Weight 16.723 kg Unit Type of Package 3 PAL Number of Units in Package 3 36 Package 3 Height 80.0 cm Package 3 Width 120.0 cm Package 3 Length 36.0 cm Package 3 Weight 208.0 kg
$185.90
Schneider Electric Schneider Electric circuit breaker Easypact EZC250H - TMD - 175 A - 3 poles 3d EZC250H3175
Description This is a 175A circuit breaker for EasyPact EZC250H. This product can work below rated operational voltage(Ue) 550VAC at 50/60Hz or 250VDC network. The ultimate breaking capacity(Icu) is shown differently, depended on the condition of network, Ics=50%Icu if need to match. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 105mm(width),165mm(height),60mm(Depth). Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250H Circuit breaker name Easypact EZC250H Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 175 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 125 V DC 1P conforming to IEC 60947-230 kA Icu at 250 V DC 2P conforming to IEC 60947-236 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-215 kA at 125 V DC conforming to IEC 60947-215 kA at 250 V DC conforming to IEC 60947-218 kA at 380 V AC 50/60 Hz conforming to IEC 60947-218 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-242.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-242.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 175 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards GB/T 14048.2EN/IEC 60947-1EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11.4 cm Package 1 Width 11.3 cm Package 1 Length 18 cm Package 1 Weight 1.64 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 13.61 kg
$130.44
Schneider Electric Schneider Electric circuit breaker,Easypact EZC400N ,TMD, 400A ,3 poles 3d EZC400N3400N
Description EasyPact EZC400N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 36kA rms at 415VAC 50/60Hz. The operational voltage is 440VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 400A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (140mm x 255mm x 110mm) comes with a variety of optional functions and accessories. Easypact EZC400N is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC400N Circuit breaker name Easypact EZC400N Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 400 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 250 V DC conforming to IEC 60947-2440 V AC 50/60 Hz conforming to IEC 60947-2 Breaking capacity code N Breaking capacity 36 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-240 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 18 kA at 440 V AC 50/60 Hz conforming to IEC 60947-220 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-218 kA at 380 V AC 50/60 Hz conforming to IEC 60947-218 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 400 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60947 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 1000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 44 mm local signalling Positive contact indication Contact position indicator Yes Magnetic tripping current 5000 A Neutral protection setting Without protection Long time pick-up adjustment type Ir Fixed Long time delay adjustment type Fixed earth-leakage protection Without height 255 mm Width 185 mm Depth 140 mm Net weight 4.8 kg Quantity per set 1 piece Colour Black Environment Standards EN/IEC 60947-2GB/T 14048.2JIS C8201-2-2EN/IEC 60947-1 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to EN 50102 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 15.200 cm Package 1 Width 16.000 cm Package 1 Length 29.400 cm Package 1 Weight 4.917 kg Unit Type of Package 2 S04 Number of Units in Package 2 3 Package 2 Height 30.000 cm Package 2 Width 40.000 cm Package 2 Length 60.000 cm Package 2 Weight 15.520 kg
$247.33
Schneider Electric Schneider Electric circuit breaker Easypact EZC100F - TMD - 25 A - 3 poles 3d EZC100F3025
Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 25A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 25 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 25 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards JIS C8201-2-2EN/IEC 60947-2EN/IEC 60947-1GB/T 14048.2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14 cm Package 1 Weight 828 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 10.42 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 331 kg
$27.50
Schneider Electric Schneider Electric circuit breaker Easypact EZC100H - TMD - 15 A - 3 poles 3d EZC100H3015
Description EasyPact EZC100H is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 30kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 15A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100H is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100H Circuit breaker name Easypact EZC100H Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 15 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 125 V DC 1P conforming to IEC 60947-210 kA Icu at 250 V DC 2P conforming to IEC 60947-210 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 15 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 125 V DC conforming to IEC 60947-25 kA at 250 V DC conforming to IEC 60947-250 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-250 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-25 kA at 440 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-27.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 15 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards EN/IEC 60947-1JIS C8201-2-2EN/IEC 60947-2GB/T 14048.2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14.0 cm Package 1 Weight 790.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.854 kg Unit Type of Package 3 PAL Number of Units in Package 3 384 Package 3 Height 80.0 cm Package 3 Width 120.0 cm Package 3 Length 384.0 cm Package 3 Weight 314.88 kg
$30.69
Schneider Electric Schneider Electric EZC250N3225 circuit breaker Easypact EZC250N - TMD - 225 A - 3 poles 3d
Description EasyPact EZC250N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 225A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (105mm x 165mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC250N is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250N Circuit breaker name Easypact EZC250N Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 225 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code N Breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 125 V DC 1P conforming to IEC 60947-220 kA Icu at 250 V DC 2P conforming to IEC 60947-225 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-210 kA at 125 V DC conforming to IEC 60947-210 kA at 250 V DC conforming to IEC 60947-225 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-24 kA at 550 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 225 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards EN/IEC 60947-2GB/T 14048.2EN/IEC 60947-1 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11 cm Package 1 Width 11.5 cm Package 1 Length 18 cm Package 1 Weight 1.57 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 12.95 kg
$129.60
Schneider Electric Schneider Electric EZC400H3320N circuit breaker, Easypact EZC400H, TMD, 320A, 3 poles 3d
Description his is a 320A circuit breaker for EasyPact EZC400H. This product can work below rated operational voltage(Ue) 440VAC at 50/60Hz. The ultimate breaking capacity(Icu) is 50kA at 440V, in terms of complete range Ics=100%Icu(Ics= 50%Icu at 440V. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 140mm(width),255mm(height),110mm(Depth). Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC400H Circuit breaker name Easypact EZC400H Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 400 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 250 V DC conforming to IEC 60947-2440 V AC 50/60 Hz conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-225 kA at 440 V AC 50/60 Hz conforming to IEC 60947-235 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 320 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60947 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 3000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 45 mm local signalling Positive contact indication Contact position indicator Yes Magnetic tripping current 4000 A Neutral protection setting Without protection Long time pick-up adjustment type Ir Fixed Long time delay adjustment type Fixed earth-leakage protection Without height 255 mm Width 185 mm Depth 140 mm Net weight 6.4 kg Quantity per set 1 piece Colour Black Environment Standards EN/IEC 60947-2GB/T 14048.2EN/IEC 60947-1JIS C8201-2-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to EN 50102 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 15.0 cm Package 1 Width 16.0 cm Package 1 Length 29.0 cm Package 1 Weight 5.231 kg Unit Type of Package 2 S04 Number of Units in Package 2 3 Package 2 Height 30.0 cm Package 2 Width 40.0 cm Package 2 Length 60.0 cm Package 2 Weight 16.459 kg Unit Type of Package 3 PAL Number of Units in Package 3 36 Package 3 Height 80.0 cm Package 3 Width 120.0 cm Package 3 Length 36.0 cm Package 3 Weight 208.0 kg
$185.90
Schneider Electric Schneider Electric EZC250H3150 circuit breaker Easypact EZC250H - TMD - 150 A - 3 poles 3d
Description This is a 150A circuit breaker for EasyPact EZC250H. This product can work below rated operational voltage(Ue) 550VAC at 50/60Hz or 250VDC network. The ultimate breaking capacity(Icu) is shown differently, depended on the condition of network, Ics=50%Icu if need to match. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 105mm(width),165mm(height),60mm(Depth). Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250H Circuit breaker name Easypact EZC250H Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 150 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 10 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-230 kA Icu at 125 V DC 1P conforming to IEC 60947-230 kA Icu at 250 V DC 2P conforming to IEC 60947-236 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-215 kA at 125 V DC conforming to IEC 60947-215 kA at 250 V DC conforming to IEC 60947-218 kA at 380 V AC 50/60 Hz conforming to IEC 60947-218 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 440 V AC 50/60 Hz conforming to IEC 60947-242.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-242.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 150 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards GB/T 14048.2EN/IEC 60947-2EN/IEC 60947-1JIS C8201-2-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11.4 cm Package 1 Width 11.3 cm Package 1 Length 18 cm Package 1 Weight 1.64 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 13.61 kg
$130.44
Schneider Electric Schneider Electric circuit breaker Easypact EZC100F - TMD - 30 A - 3 poles 3d
Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 30A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 30 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 30 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards EN/IEC 60947-1GB/T 14048.2JIS C8201-2-2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14.0 cm Package 1 Weight 763.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.512 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 120 cm Package 3 Length 80 cm Package 3 Weight 318 kg
$29.22
Schneider Electric Schneider Electric circuit breaker Easypact EZC250N - TMD - 200 A - 3 poles 3d
Description EasyPact EZC250N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 200A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (105mm x 165mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC250N is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250N Circuit breaker name Easypact EZC250N Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 200 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code N Breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 125 V DC 1P conforming to IEC 60947-220 kA Icu at 250 V DC 2P conforming to IEC 60947-225 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-210 kA at 125 V DC conforming to IEC 60947-210 kA at 250 V DC conforming to IEC 60947-225 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-24 kA at 550 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 200 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards EN/IEC 60947-1GB/T 14048.2EN/IEC 60947-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 10.5 cm Package 1 Width 11.5 cm Package 1 Length 18.0 cm Package 1 Weight 1.57 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 12.94 kg Unit Type of Package 3 P12 Number of Units in Package 3 64 Package 3 Height 50 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 120.86 kg Contractual warranty Warranty 18 months
$121.00
Schneider Electric Schneider Electric circuit breaker Easypact EZC100F - TMD - 60 A - 3 poles 3d
Description EasyPact EZC100F is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 10kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 60A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (75mm x 130mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC100F is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC100F Circuit breaker name Easypact EZC100F Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 60 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code F Breaking capacity 25 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-25 kA Icu at 125 V DC 1P conforming to IEC 60947-25 kA Icu at 250 V DC 2P conforming to IEC 60947-25 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-27.5 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 12.5 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-22.5 kA at 125 V DC conforming to IEC 60947-22.5 kA at 250 V DC conforming to IEC 60947-22.5 kA at 550 V AC 50/60 Hz conforming to IEC 60947-25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-25 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-23.75 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 60 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 8500 cycles Electrical durability Category A: 1500 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 25 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 130 mm Width 75 mm Depth 60 mm Environment Standards EN/IEC 60947-2JIS C8201-2-2EN/IEC 60947-1GB/T 14048.2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9.5 cm Package 1 Width 8.5 cm Package 1 Length 14.0 cm Package 1 Weight 786.0 g Unit Type of Package 2 S02 Number of Units in Package 2 12 Package 2 Height 15.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 9.792 kg Unit Type of Package 3 P12 Number of Units in Package 3 384 Package 3 Height 75 cm Package 3 Width 120 cm Package 3 Length 80 cm Package 3 Weight 326 kg Contractual warranty Warranty 18 months
$35.31
Schneider Electric Schneider Electric circuit breaker Easypact EZC400H - TMD - 350 A - 3 poles 3
Description This is a 350A circuit breaker for EasyPact EZC400H. This product can work below rated operational voltage(Ue) 440VAC at 50/60Hz. The ultimate breaking capacity(Icu) is 50kA at 440V, in terms of complete range Ics=100%Icu(Ics= 50%Icu at 440V. This version of product is designed 3 poles frame with detection on 3 poles,equiped TMD trip unit for thermal-magnetic protection. It is compliance with standard IEC60947, CE certification and some independent lab(KEMA,ASEFA,TUV) or third-party Tilva. This device is certified for operation in pollution degree III environment as defined by IEC60947, and pass the test of extremely atmospheric conditions. Device can be mounted vertically or horizontally in a metal enclosure,and against from safety risk by padlocking. The degree of protection is IP40 for direct rotary handle,and IP54 for extended rotary handle. This series have slots used for indication or voltage release auxiliaries positioning , depending on where it is inserted in the device behind the front cover of circuit breaker. The fixed dimension is 140mm(width),255mm(height),110mm(Depth). Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC400H Circuit breaker name Easypact EZC400H Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 400 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 250 V DC conforming to IEC 60947-2440 V AC 50/60 Hz conforming to IEC 60947-2 Breaking capacity code H Breaking capacity 50 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-270 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 25 kA at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-225 kA at 440 V AC 50/60 Hz conforming to IEC 60947-235 kA at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 350 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60947 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 1000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 44 mm local signalling Positive contact indication Contact position indicator Yes Magnetic tripping current 3200 A Neutral protection setting Without protection Long time pick-up adjustment type Ir Fixed Long time delay adjustment type Fixed earth-leakage protection Without height 255 mm Width 185 mm Depth 140 mm Net weight 6.4 kg Quantity per set 1 piece Colour Black Environment Standards GB/T 14048.2EN/IEC 60947-2EN/IEC 60947-1JIS C8201-2-2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to EN 50102 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 15.0 cm Package 1 Width 16.0 cm Package 1 Length 29.0 cm Package 1 Weight 5.313 kg Unit Type of Package 2 S04 Number of Units in Package 2 3 Package 2 Height 30.0 cm Package 2 Width 40.0 cm Package 2 Length 60.0 cm Package 2 Weight 16.705 kg Unit Type of Package 3 PAL Number of Units in Package 3 36 Package 3 Height 80.0 cm Package 3 Width 120.0 cm Package 3 Length 36.0 cm Package 3 Weight 208.0 kg Contractual warranty Warranty 18 months
$236.50
Schneider Electric Schneider Electric circuit breaker Easypact EZC250N - TMD - 175 A - 3 poles 3d
Description EasyPact EZC250N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 175A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (105mm x 165mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC250N is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250N Circuit breaker name Easypact EZC250N Device application Distribution Poles description 3P Protected poles description 3t Network type ACDC Network frequency 50/60 Hz [In] rated current 175 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code N Breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 125 V DC 1P conforming to IEC 60947-220 kA Icu at 250 V DC 2P conforming to IEC 60947-225 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-210 kA at 125 V DC conforming to IEC 60947-210 kA at 250 V DC conforming to IEC 60947-225 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-24 kA at 550 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 175 A at 50 °C Protection type Overload protectionShort-circuit protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards EN/IEC 60947-2GB/T 14048.2EN/IEC 60947-1 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11 cm Package 1 Width 11.5 cm Package 1 Length 18 cm Package 1 Weight 1.57 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 13 kg Contractual warranty Warranty 18 months
$121.00
Schneider Electric Schneider Electric circuit breaker Easypact EZC250N - TMD - 250 A - 3 poles 3d
Description EasyPact EZC250N is a 3 poles fixed circuit breaker designed for the protection of low voltage electrical installations. It is used for standard applications in industries and buildings, offering good performance at competitive price The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 550VAC 50/60Hz or 250VDC. The rating of the thermal-magnetic trip unit is 250A. The trip unit provides fixed overload and instantaneous protections. This 3 poles version (105mm x 165mm x 60mm) comes with a variety of optional functions and accessories. Easypact EZC250N is compliant with international standards (IEC 60947, UL 508) and marine certifications. Specifications Main range of product EasyPact Product or component type Circuit breaker Device short name Easypact EZC250N Circuit breaker name Easypact EZC250N Device application Distribution Poles description 3P Protected poles description 3t Network type DCAC Network frequency 50/60 Hz [In] rated current 250 A at 40 °C [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 [Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2250 V DC conforming to IEC 60947-2 Breaking capacity code N Breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 125 V DC 1P conforming to IEC 60947-220 kA Icu at 250 V DC 2P conforming to IEC 60947-225 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-225 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-225 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-210 kA at 125 V DC conforming to IEC 60947-210 kA at 250 V DC conforming to IEC 60947-225 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-24 kA at 550 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-212.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category A Trip unit name TM-D Trip unit technology Thermal-magnetic Trip unit rating 250 A at 50 °C Protection type Short-circuit protectionOverload protection Pollution degree 3 conforming to IEC 60664-13 conforming to IEC 947-1 Complementary Control type Toggle Mounting mode Fixed mounting support Backplate Upside connection Front downside connection Front Mechanical durability 10000 cycles Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2 Connection pitch 35 mm local signalling Positive contact indication Neutral protection setting Without protection earth-leakage protection Without height 165 mm Width 105 mm Depth 60 mm Environment Standards EN/IEC 60947-2EN/IEC 60947-1GB/T 14048.2 IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK07 conforming to IEC 62262 Ambient air temperature for operation -25…70 °C Ambient air temperature for storage -35…85 °C Packing Units Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 12.0 cm Package 1 Width 11.0 cm Package 1 Length 18.2 cm Package 1 Weight 1.583 kg Unit Type of Package 2 S03 Number of Units in Package 2 8 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 14.09 kg Unit Type of Package 3 P12 Number of Units in Package 3 64 Package 3 Height 50 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 124.7 kg Contractual warranty Warranty 18 months
$121.00