LS ELECTRIC Low Voltage Circut Breakers

381 products


  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN803c 700A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 700A

    General Product code 0166000300 Product description ABN803c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.

    $675.51

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN803c 630A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 630A

    General Product code 0166002400 Product description ABN803c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.

    $675.51

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN803c 500A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN803c 500A

    General Product code 0166002300 Product description ABN803c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-63 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 210 mm Height 280 mm Depth 109 mm Weight 8.8 kg Packing Width 230 mm Height 283 mm Depth 165 mm Weight 8.8 kg Quantity (in a box) 1 pcs.

    $675.51

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN804c 800A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 800A

    General Product code 0166000600 Product description ABN804c 800A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 800 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.

    $789.69

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN804c 700A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 700A

    General Product code 0166000500 Product description ABN804c 700A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 700 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.

    $789.69

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN804c 630A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 630A

    General Product code 0166002600 Product description ABN804c 630A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 630 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.

    $789.69

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN804c 500A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN804c 500A

    General Product code 0166002500 Product description ABN804c 500A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 500 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 2500 cycles Electrical durability (AC) 500 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 50 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 45 kA at 380 V AC 50/60 Hz, IEC 60947-2 37 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 25 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 105 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 94.5 kA at 380 V AC 50/60 Hz, IEC 60947-2 77.7 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 52.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-64 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 10 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) - Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 280 mm Height 280 mm Depth 109 mm Weight 11.4 kg Packing Width 289 mm Height 294 mm Depth 165 mm Weight 11.4 kg Quantity (in a box) 1 pcs.

    $789.69

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 250A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 250A

    General Product code 0137005900 Product description ABN203c 250A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 250 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 225A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 225A

    General Product code 0137005800 Product description ABN203c 225A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 225 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 200A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 200A

    General Product code 0137005700 Product description ABN203c 200A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 200 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 175A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 175A

    General Product code 0137005600 Product description ABN203c 175A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 175 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 150A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 150A

    General Product code 0137005500 Product description ABN203c 150A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 150 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 125A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 125A

    General Product code 0137005400 Product description ABN203c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABN203c 100A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABN203c 100A

    General Product code 0137005300 Product description ABN203c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 20000 cycles Electrical durability (AC) 5000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 65 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 30 kA at 380 V AC 50/60 Hz, IEC 60947-2 26 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 18 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 8 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 10 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 143 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 63 kA at 380 V AC 50/60 Hz, IEC 60947-2 54.6 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 36 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 13.6 kA at 690 V AC 50/60 Hz, IEC 60947-39 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 105 mm Height 165 mm Depth 60 mm Weight 1.2 kg Packing Width 375 mm Height 585 mm Depth 105 mm Weight 13.9 kg Quantity (in a box) 10 pcs.

    $137.83

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH52c 50A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 50A

    General Product code 0133001400 Product description ABH52c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH52c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 40A

    General Product code 0133001300 Product description ABH52c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH52c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 30A

    General Product code 0133001200 Product description ABH52c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH52c 20A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 20A

    General Product code 0133001100 Product description ABH52c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH52c 15A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH52c 15A

    General Product code 0133001000 Product description ABH52c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-26 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH53c 50A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 50A

    General Product code 0134001400 Product description ABH53c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH53c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 40A

    General Product code 0134001300 Product description ABH53c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH53c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 30A

    General Product code 0134001200 Product description ABH53c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH53c 20A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 20A

    General Product code 0134001100 Product description ABH53c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH53c 15A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH53c 15A

    General Product code 0134001000 Product description ABH53c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-27 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH54c 50A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 50A

    General Product code 0135001400 Product description ABH54c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH54c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 40A

    General Product code 0135001300 Product description ABH54c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH54c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 30A

    General Product code 0135001200 Product description ABH54c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH54c 20A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 20A

    General Product code 0135001100 Product description ABH54c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH54c 15A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH54c 15A

    General Product code 0135001000 Product description ABH54c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-28 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 125A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 125A

    General Product code 0133002300 Product description ABH102c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 100A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 100A

    General Product code 0133002200 Product description ABH102c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 75A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 75A

    General Product code 0133002100 Product description ABH102c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 60A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 60A

    General Product code 0133002000 Product description ABH102c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 50A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 50A

    General Product code 0133001900 Product description ABH102c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 40A

    General Product code 0133001800 Product description ABH102c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 30A

    General Product code 0133001700 Product description ABH102c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 20A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 20A

    General Product code 0133001600 Product description ABH102c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH102c 15A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH102c 15A

    General Product code 0133001500 Product description ABH102c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 2P Protected poles description 2T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 30 kA at 250 V DC (2poles in series), Reference - - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-32 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 60 mm Height 155 mm Depth 60 mm Weight 0.7 kg Packing Width 340 mm Height 475 mm Depth 105 mm Weight 7.4 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 125A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 125A

    General Product code 0134002300 Product description ABH103c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 100A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 100A

    General Product code 0134002200 Product description ABH103c 100A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 100 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 75A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 75A

    General Product code 0134002100 Product description ABH103c 75A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 75 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 60A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 60A

    General Product code 0134002000 Product description ABH103c 60A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 60 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 50A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 50A

    General Product code 0134001900 Product description ABH103c 50A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 50 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 40A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 40A

    General Product code 0134001800 Product description ABH103c 40A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 40 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 30A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 30A

    General Product code 0134001700 Product description ABH103c 30A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 30 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 20A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 20A

    General Product code 0134001600 Product description ABH103c 20A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 20 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH103c 15A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH103c 15A

    General Product code 0134001500 Product description ABH103c 15A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 15 A at 40 ℃ Poles description 3P Protected poles description 3T Neutral position - Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-33 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 400 A, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) LR (U.K) BV (France) ABS (U.S.A) GL (Germany) DNV (Norway) RINA (Italy) KR (Korea) 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 90 mm Height 155 mm Depth 60 mm Weight 1 kg Packing Width 340 mm Height 515 mm Depth 105 mm Weight 10.6 kg Quantity (in a box) 10 pcs.

  • LS ELECTRIC Metasol Molded Case Circuit Breaker  MCCB Standard  ABH104c 125A

    LS ELECTRIC LS ELECTRIC Metasol Molded Case Circuit Breaker MCCB Standard ABH104c 125A

    General Product code 0135002300 Product description ABH104c 125A EXP Trip Unit FTU(Fixed-thermal, Fixed-magnetic) [In] rated current 125 A at 40 ℃ Poles description 4P Protected poles description 3T Neutral position R-S-T-N Network type AC (50/60 Hz), DC Upside connection Front (screw) Downside connection Front (screw) Characteristics [Ue] rated operational voltage (AC 50/60 Hz) 690 V AC [Ue] rated operational voltage (DC) 500 V DC [Uimp] rated impulse withstand voltage 8 kV [Ui] rated insulation voltage 1000 V Mechanical durability 25000 cycles Electrical durability (AC) 10000 cycles Electrical durability (DC) - Utilisation category Category A Suitability for isolation Yes Reference standard IEC 60947-2 [Icu] rated Ultimate short-circuit breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Ics] rated service breaking capacity 100 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 50 kA at 380 V AC 50/60 Hz, IEC 60947-2 50 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 35 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 10 kA at 690 V AC 50/60 Hz, IEC 60947-2 - 30 kA at 500 V DC (3poles in series), Reference - [Icm] rated short-circuit marking capacity 220 kA at 220/250 V AC 50/60 Hz, IEC 60947-2 105 kA at 380 V AC 50/60 Hz, IEC 60947-2 105 kA at 415/460 V AC 50/60 Hz, IEC 60947-2 73.5 kA at 480/500 V AC 50/60 Hz, IEC 60947-2 17 kA at 690 V AC 50/60 Hz, IEC 60947-34 - [Icw] rated short-time withstand current - - - - Trip unit characteristics Thermal-magnetic L : for overload protection (long time) - I : for instantaneous short-circuit protection - - - - - - [Ir] Long-time pick-up adjustment range Fixed - [Iu] Long-time pick-up adjustment range - - [tr] Long-time delay adjustment range - - [Isd] Short-time pick-up adjustment range - - [tsd] Short-time delay adjustment range - - - - - - - [Ii] Instantaneous pick-up adjustment range Fixed 12 x In, tolerance ±20% [Ig] Ground-fault protection pick-up adjustment range - - [tg] Ground-fault protection time delay adjustment range - - - - - - - Earth leakage pick-up adjustment range - - Earth leakage alam time delay adjustment range - - Earth leakage trip time delay adjustment range - - [Ip] Pre-trip alarm pick-up adjustment range - - [tp] Pre-trip alarm time delay adjustment range - - Alarm LED - - Environment Pollution degree 3, IEC 60664-1 Degree of protection IP20, IEC 60529 Ambient air temperature for operation -20…70 °C Ambient air temperature for storage -40…70 °C Mounting mode Fixed Mounting support Backplate Approvals1) (General) CE (Europe) - - CCC (China) EAC (Russia) IC (Korea) Approvals (Marine) - - - - - - - 1) LS ELECTRIC's standard products are designed for CE. To check the product with regional certificates, please contact LSE sales representatives. Dimensions Product Width 120 mm Height 155 mm Depth 60 mm Weight 1.2 kg Packing Width 340 mm Height 665 mm Depth 105 mm Weight 14.1 kg Quantity (in a box) 10 pcs.

    $115.06