Autonics
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFAWT30-10DO-IV
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$141.50
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT08-1.5DO-V
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 55 g (≈ 80 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$67.47
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT12-2DO-V
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 83 g (≈ 110 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$57.42
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT18-5DO-V
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$67.47
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFT30-10DO-V
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$76.60
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT08-1.5DO-IV
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 200Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 55 g (≈ 80 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 10 times) Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$72.03
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT12-2DO-IV
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 100Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 83 g (≈ 110 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$61.98
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT18-5DO-IV
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 80Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 97 g (≈ 132 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$72.03
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFD12-3DN-V-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 80 g (≈ 110 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$104.00
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFD12-3DP-V-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 80 g (≈ 110 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$104.00
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFD18-7DP-V-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 100 g (≈ 135 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$113.11
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFD30-12DN-V-K
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 165 g (≈ 220 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$123.14
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFD30-12DP-V-K
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 165 g (≈ 220 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$118.40
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDA12-3DN-V-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 80 g (≈ 110 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$132.26
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDA12-3DP-V-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 80 g (≈ 110 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$132.26
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDA18-7DN-V-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 100 g (≈ 135 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$137.74
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDA18-7DP-V-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 100 g (≈ 135 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$137.74
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDA30-12DN-V-K
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 165 g (≈ 220 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$142.30
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDA30-12DP-V-K
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 165 g (≈ 220 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$142.30
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM12-3DN-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 15 g (≈ 40 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$141.38
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM12-3DP-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 15 g (≈ 40 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$141.38
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM18-7DN-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 32 g (≈ 67 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$146.85
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM30-12DN-K
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 85 g (≈ 140 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$151.42
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM30-12DP-K
Installation Flush Sensing side diameter Ø30mm Sensing distance 12mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 85 g (≈ 140 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$151.42
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDAW12-3DN-V-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 35 g (≈ 60 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$136.82
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDAW12-3DP-V-K
Installation Flush Sensing side diameter Ø12mm Sensing distance 3mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 21×21×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 35 g (≈ 60 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$136.82
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDAW18-7DN-V-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 55 g (≈ 90 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable connector type Connector type M12 plug connector Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$142.30
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRWL08-2DP
Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 34 g (≈ 46 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW30-10DN
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 400Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 122 g (≈ 134 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$22.81
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFDACM18-7DP-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 32 g (≈ 67 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard), IP67G (JEM standard), IP68 Connection Connector models Connector type M12 plug connector Material Case / Nut: stainless steel 303 (SUS303, PTFE coated), rear cap: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303, PTFE coated)
$146.85
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DN2
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Proximity Sensor Cylindrical Long-Range DC 3-Wire PRFD18-7DN-V-K
Installation Flush Sensing side diameter Ø18mm Sensing distance 7mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 30×30×1mm(iron) Response frequency 10 Hz Indicator Stable indicator (green), unstable indicator (orange), Abnormal detect indicator (cross-flashing green, orange) Unit weight (packaged weight) ≈ 100 g (≈ 135 g) Power voltage 10 - 30 VDC(ripple P-P: ≤ 10 %) Current specification Current consumption: Max. 20mA Control output Max. 100mA Residual voltage ≤ 2.5 V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP66, IP67 (IEC standard) Connection Cable type Cable Standard/material Oil resistant cable (dark gray) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$113.11
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW12-2DN
Installation Flush Sensing side diameter Ø12mm Sensing distance 2mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 42 g (≈ 54 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$20.47
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW12-4DP
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 42 g (≈ 54 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$20.93
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW18-8DP
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRFWT30-10DO-IV
Installation Flush Sensing side diameter Ø30mm Sensing distance 10mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 54×54×1mm(iron) Response frequency 50Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 170 g (≈ 225 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.8mA Control output 3 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,000 VAC~ 50/60 Hz for 1 minute Vibration 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours Shock 1,000 m/s² (≈ 100 G) in each X, Y, Z direction for 10 times Environment_Ambient temperature -25 to 70 ℃, storage: -25 to 70 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Oil resistant cable (gray): polyvinyl chloride (oil resistant PVC) Material Case / Nut: stainless steel 303 (SUS303), washer: stainless steel 304 (SUS304), sensing side: stainless steel 303 (SUS303)
$81.15
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-2DP
Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW12-4DN
Installation Non-flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 42 g (≈ 54 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$20.47
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW18-8DN
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.30
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-2DN
Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.09
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT18-8DO
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW18-8DN2
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT08-1.5DO
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 2-Wire PRWT18-8DC
Installation Non-flush Sensing side diameter Ø18mm Sensing distance 8mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 25×25×1mm(iron) Response frequency 350Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.99
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW08-1.5DP
Installation Flush Sensing side diameter Ø8mm Sensing distance 1.5mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1.5kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 32 g (≈ 44 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRWL08-2DN
Installation Non-flush Sensing side diameter Ø8mm Sensing distance 2mm Hysteresis(distance) Max. 15% of sensing distance Standard sensing target 8×8×1mm(iron) Response frequency 1kHz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 34 g (≈ 46 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 2V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$24.55
Autonics Autonics Proximity Sensor Cylindrical Long-Range Proximity Sensor PRDAT12-4DO
Installation Flush Sensing side diameter Ø12mm Sensing distance 4mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 12×12×1mm(iron) Response frequency 450Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 72g (≈ 84g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Leakage current: Max. 0.6mA Control output 2 to 100 mA Residual voltage Max. 3.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength 1,500 VAC~ 50/60Hz for 1 minute Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable type Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: PTFE coated brass, washer: PTFE coated iron, sensing side: PTFE
$46.42
Autonics Autonics Proximity Sensor Cylindrical Proximity Sensor DC 3-Wire PRW18-5DN
Installation Flush Sensing side diameter Ø18mm Sensing distance 5mm Hysteresis(distance) Max. 10% of sensing distance Standard sensing target 18×18×1mm(iron) Response frequency 500Hz Indicator Operation indicator (red LED) Unit weight (packaged weight) ≈ 58 g (≈ 70 g) Power voltage 12 - 24 VDC(ripple P-P: ≤ 10 %), operating voltage: 10 - 30 VDC Current specification Current consumption: Max. 10mA Control output ≤ 200 mA Residual voltage Max. 1.5V Protection circuit Surge protection circuit, output short over current protection circuit, reverse polarity protection circuit Insulation resistance ≥ 50 MΩ (500 VDC megger) Dielectric strength Between the charging part and the case: 1,500 VAC~ 50 / 60Hz for 1 min Vibration 1.0 mm amplitude at frequency of 10 to 55 Hzin each X, Y, Z direction for 2 hours Shock 500 m/s² (≈ 50 G) in each X, Y, Z direction for 3 times Environment_Ambient temperature -25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation) Environment_Ambient humidity 35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation) Protection structure IP67(IEC standard) Connection Cable connector type Connector type M12 Connector Cable Standard/material Standard type cable (black): polyvinyl chloride (PVC) Material Case/Nut: nickel plated brass (DIA. of sensing side Ø 8 mm connector type case: SUS303), washer: nickel plated iron, sensing side: PBT
$19.65