PEACOCK
PEACOCK Peacock One Revolution Test Indicators (without change lever type), PCN-1LZA
Peacock One Revolution Test Indicators (without change lever type), PCN-1LZAA The dial face is easy to read with light yellow and blue (dead zone) Model PCN-1LZA Graduation 0.01mm Range 0.8mm Contact point (XN1L-2) is attached Graduation (mm) Range (mm) Movable Range (mm) Indication error (µm) Measuring force less than (N) L(mm) Whole measuring range Adjacent error Backward error 0.01 0.8 0.9 8 5 4 0.3 42.8
$164.15
PEACOCK Peacock One Revolution Dial Gauges; 0.01mm, 47Z-XB, Range 0.8mm
Peacock One Revolution Dial Gauges; 0.01mm, 47Z-XB, Range 0.8mm Model 47Z-XB Graduation 0.01mm Range 0.8mm Long stem Flat back Contact Point ( XB-1 ) These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-freedue to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange(dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 47Z-XB 0.01 0.8(4.0) 40-0-40 9 - ±13 - 6 5 1.4 Dimensions (mm) Model A B C D E F G H I K 47Z-XB 61.9 20 30 36 13 15 4 5.8 32 43.9
$143.18
PEACOCK Peacock One Revolution Dial Gauges; 0.01mm, 47SZ, Range 0.8mm,Small dial face ( Ø36 )
Peacock One Revolution Dial Gauges; 0.01mm, 47SZ, Range 0.8mm,Small dial face ( Ø36 ) Model 47SZ Graduation 0.01mm Range 0.8mm Small dial face ( Ø36 ) Flat back Contact Point ( XB-1 ) These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-freedue to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange(dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 47SZ 0.01 0.8(4.0) 40-0-40 9 - ±13 - 6 5 1.4 Dimensions (mm) Model A B C D E F G H I K 47SZ 41.1 20 9.7 36 13 15 3.5 6.5 32 23.1
$157.92
PEACOCK Peacock One Revolution Dial Gauges; 0.01mm , Range 1.0mm, 117Z
Peacock One Revolution Dial Gauges; 0.01mm , Range 1.0mm, 117Z Model 117Z Graduation 0.01mm Range 1.0mm Contact Point ( XB-1 ) Flat back These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-free due to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange (dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 117Z 0.01 1.0(7.0) 50-0-50 8 ±9 ±10 - - 5 5 1.4 Dimensions (mm) Model A B C D E F G H I 117Z 65 41.5 18.5 53 14.5 20 4 6.5 49
$158.46
PEACOCK Peacock One Revolution Dial Gauges; 0.01mm , Range 0.8mm, Oil-proof type, 17Z-SWA
Peacock One Revolution Dial Gauges; 0.01mm , Range 0.8mm, Oil-proof type, 17Z-SWA Model 17Z-SWA Graduation 0.01mm Range 0.8mm Contact Point ( XB-2A ) Oil-proof type Flat back These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-free due to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange (dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 17Z-SWA 0.01 0.8(7.0) 40-0-40 8 ±9 ±10 - - 5 5 1.4 Dimensions (mm) Model A B C D E F G H I 17Z-SWA 65 41.5 18.5 53 14.5 20 4 6.5 49
$194.17
PEACOCK Peacock One Revolution Dial Gauges; 0.01mm , Range 0.8mm 17Z
Peacock One Revolution Dial Gauges; 0.01mm , Range 0.8mm 17Z Model 17Z Graduation 0.01mm Range 0.8mm Contact Point ( XB-1 ) Flat back These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-free due to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange (dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 17Z 0.01 0.8(7.0) 40-0-40 8 ±9 ±10 - - 5 5 1.4 Dimensions (mm) Model A B C D E F G H I 17Z 65 41.5 18.5 53 14.5 20 4 6.5 49
$111.38
PEACOCK Peacock One Revolution Dial Gauges; 0.001mm, 5Z-XB, Range 0.14mm
Peacock One Revolution Dial Gauges; 0.001mm, 5Z-XB, Range 0.14mm Model 5Z-XB Graduation 0.001mm Range 0.14mm Contact Point ( XB-1 ) Flat back These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-free due to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange (dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 5Z-XB 0.001 0.14(3.0) 70-0-70 2.5 ±3 ±4 - - 3 0.5 1.5 Dimensions (mm) Model A B C D E F G H I 5Z-XB 69.4 41.5 30 53 14.5 20 4 6.5 49
$186.34
PEACOCK Peacock One Revolution Dial Gauges; 0.001mm, 18, Range 0.16mm,Oil-proof type
Peacock One Revolution Dial Gauges; 0.001mm, 18, Range 0.16mm,Oil-proof type Model 18 Graduation 0.001mm Range 0.16mm Long stem Contact Point ( XB-1 ) Oil-proof type Flat crystal Flat back These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-free due to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange (dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 18 0.001 0.16(3.0) 80-0-80 2.5 ±3 ±4 - - 3 0.5 1.5 Dimensions (mm) Model A B C D E F G H I 18 69.4 41.5 29 55 16.8 20 4 6.5 49
$257.40
PEACOCK Peacock One Revolution Dial Gauges; 0.001mm, 15DZ, Range 0.16mm,Large dial face ( Ø66.5 )
Peacock One Revolution Dial Gauges; 0.001mm, 15DZ, Range 0.16mm,Large dial face ( Ø66.5 ) Model 15DZ Graduation 0.001mm Range 0.16mm Large dial face ( Ø66.5 ) Contact Point ( XB-1 ) Flat back These are high-accuracy dial gauges with the pointer giving less than a full turn that can resist rigorous rigorous continuous measurement. The long stem is made of stainless steel, is high in strenght and is malfunction-freedue to fastening. The dial faces except No. 18 and 17B are easy to read with green and orange (dead zone) Model Graduation (mm) Range (mm) (Free stroke) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 15DZ 0.001 0.16(3.0) 80-0-80 2.5 ±3 ±4 - - 3 0.7 1.5 Dimensions (mm) Model A B C D E F G H I 15DZ 69.4 41.5 23.7 66.5 15.5 20 4 7.6 49
$269.65
PEACOCK Peacock Non-electrifying & Complete Anti-magnetic, PCN-SU Test Indicators
Peacock Non-electrifying & Complete Anti-magnetic, PCN-SU Test Indicators Model PCN-SU Graduation 0.001mm Range 0.14mm High accuracy When non-electrifying type of Pic Test or New Pic Test is used, electric flow is blocked at the ceramic stem, even of a magnetic stand is electrified. Thus, you can continue your work without any problem. The dial face is light blue color and easy to read. Specifications and outer dimensions are the same as those of standard PC and PCN types, except the portion of stems Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.001 0.14 0 - 70 - 0 3 2 2 0.3 11.7
$307.67
PEACOCK Peacock Non-electrifying & Complete Anti-magnetic, PCN-6U Test Indicators (Vertical)
Peacock Non-electrifying & Complete Anti-magnetic, PCN-6U Test Indicators (Vertical) Model PCN-6U Graduation 0.002mm Range 0.28mm High accuracy When non-electrifying type of Pic Test or New Pic Test is used, electric flow is blocked at the ceramic stem, even of a magnetic stand is electrified. Thus, you can continue your work without any problem. The dial face is light blue color and easy to read. Specifications and outer dimensions are the same as those of standard PC and PCN types, except the portion of stems Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.002 0.28 0 - 140 - 0 3 2 2 0.3 17.8
$290.45
PEACOCK Peacock Non-electrifying & Complete Anti-magnetic, PCN-5U Test Indicators (Vertical)
Peacock Non-electrifying & Complete Anti-magnetic, PCN-5U Test Indicators (Vertical) Model PCN-5U Graduation 0.01mm Range 0.5mm High accuracy When non-electrifying type of Pic Test or New Pic Test is used, electric flow is blocked at the ceramic stem, even of a magnetic stand is electrified. Thus, you can continue your work without any problem. The dial face is light blue color and easy to read. Specifications and outer dimensions are the same as those of standard PC and PCN types, except the portion of stems Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.01 0.5 0 - 25 - 0 5 5 3 0.3 21.3
$262.20
PEACOCK Peacock Non-electrifying & Complete Anti-magnetic, PCN-1BU Test Indicators
Peacock Non-electrifying & Complete Anti-magnetic, PCN-1BU Test Indicators Model PCN-1BU Graduation 0.01mm Range 0.8mm When non-electrifying type of Pic Test or New Pic Test is used, electric flow is blocked at the ceramic stem, even of a magnetic stand is electrified. Thus, you can continue your work without any problem. The dial face is light blue color and easy to read. Specifications and outer dimensions are the same as those of standard PC and PCN types, except the portion of stems Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.01 0.8 0 - 40 - 0 8 5 3 0.3 22.2
$243.56
PEACOCK Peacock Non-electrifying & Complete Anti-magnetic, PCN-1AU Test Indicators
Peacock Non-electrifying & Complete Anti-magnetic, PCN-1AU Test Indicators Model PCN-1AU Graduation 0.01mm Range 0.5mm When non-electrifying type of Pic Test or New Pic Test is used, electric flow is blocked at the ceramic stem, even of a magnetic stand is electrified. Thus, you can continue your work without any problem. The dial face is light blue color and easy to read. Specifications and outer dimensions are the same as those of standard PC and PCN types, except the portion of stems Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.01 0.5 0 - 25 - 0 5 5 3 0.3 21.3
$251.02
PEACOCK Peacock NEW PIC TEST ; Without change lever, PCN-S
Peacock NEW PIC TEST ; Without change lever, PCN-S The New Pic Test is a lever type dial indicators used in all over the world. It is a measuring instrument used for measurements of restricted areas,and the outside/inside, groove width and centering with the dial gauge installed to the lathe or the milling cutting machine for measurements with the gauges held on the height gauges. Model PCN-S Graduation 0.001mm Range 0.14mm Without change lever (Automatic inverse type) The lever type dial gauge of this type has no change lever, the contact point inverses automatically in normal or reverse direction as desired and pointer turns always CW to improve the measuring efficiency. Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning sectionof the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) Wide-range forward accuracy Adjacent error Backward error 0.001 0.14 0 - 70 - 0 3 2 2 0.3 Dimensions Model L (mm) PCN-S 11.7
$149.23
PEACOCK Peacock NEW PIC TEST ; Without change lever, PCN-6 Vertical
Peacock NEW PIC TEST ; Without change lever, PCN-6 Vertical The New Pic Test is a lever type dial indicators used in all over the world. It is a measuring instrument used for measurements of restricted areas,and the outside/inside, groove width and centering with the dial gauge installed to the lathe or the milling cutting machine for measurements with the gauges held on the height gauges. Model PCN-6 Vertical Graduation 0.002mm Range 0.28mm Without change lever (Automatic inverse type) The lever type dial gauge of this type has no change lever, the contact point inverses automatically in normal or reverse direction as desired and pointer turns always CW to improve the measuring efficiency. Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning sectionof the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) Wide-range forward accuracy Adjacent error Backward error 0.002 0.28 0 -140 - 0 3 2 2 0.3 Dimensions Model L (mm) PCN-6 17.8
$192.58
PEACOCK Peacock NEW PIC TEST ; Without change lever, PCN-2
Peacock NEW PIC TEST ; Without change lever, PCN-2 The New Pic Test is a lever type dial indicators used in all over the world. It is a measuring instrument used for measurements of restricted areas,and the outside/inside, groove width and centering with the dial gauge installed to the lathe or the milling cutting machine for measurements with the gauges held on the height gauges. Model PCN-2 Graduation 0.002mm Range 0.28mm Without change lever (Automatic inverse type) The lever type dial gauge of this type has no change lever, the contact point inverses automatically in normal or reverse direction as desired and pointer turns always CW to improve the measuring efficiency. Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning sectionof the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) Wide-range forward accuracy Adjacent error Backward error 0.002 0.28 0 - 140 - 0 3 2 2 0.3 Dimensions Model L (mm) PCN-2 17.8
$149.23
PEACOCK Peacock NEW PIC TEST ; Without change lever, PCN-1L
Peacock NEW PIC TEST ; Without change lever, PCN-1L The New Pic Test is a lever type dial indicators used in all over the world. It is a measuring instrument used for measurements of restricted areas,and the outside/inside, groove width and centering with the dial gauge installed to the lathe or the milling cutting machine for measurements with the gauges held on the height gauges. Model PCN-1L Graduation 0.01mm Range 1.0mm Without change lever (Automatic inverse type) The lever type dial gauge of this type has no change lever, the contact point inverses automatically in normal or reverse direction as desired and pointer turns always CW to improve the measuring efficiency. Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning sectionof the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) Wide-range forward accuracy Adjacent error Backward error 0.01 1.0 0 - 50 - 0 10 5 4 0.3 Dimensions Model L (mm) PCN-1L 42.8
$149.23
PEACOCK Peacock NEW PIC TEST ; Without change lever, PCN-1B
Peacock NEW PIC TEST ; Without change lever, PCN-1B The New Pic Test is a lever type dial indicators used in all over the world. It is a measuring instrument used for measurements of restricted areas,and the outside/inside, groove width and centering with the dial gauge installed to the lathe or the milling cutting machine for measurements with the gauges held on the height gauges. Model PCN-1B Graduation 0.01mm Range 0.8mm Without change lever (Automatic inverse type) The lever type dial gauge of this type has no change lever, the contact point inverses automatically in normal or reverse direction as desired and pointer turns always CW to improve the measuring efficiency. Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning sectionof the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) Wide-range forward accuracy Adjacent error Backward error 0.01 0.8 0 - 40 - 0 8 5 3 0.3 Dimensions Model L (mm) PCN-1B 22.2
$139.27
PEACOCK Peacock NEW PIC TEST ; Without change lever, PCN-1A
Peacock NEW PIC TEST ; Without change lever, PCN-1A The New Pic Test is a lever type dial indicators used in all over the world. It is a measuring instrument used for measurements of restricted areas,and the outside/inside, groove width and centering with the dial gauge installed to the lathe or the milling cutting machine for measurements with the gauges held on the height gauges. Model PCN-1A Graduation 0.01mm Range 0.5mm Without change lever (Automatic inverse type) The lever type dial gauge of this type has no change lever, the contact point inverses automatically in normal or reverse direction as desired and pointer turns always CW to improve the measuring efficiency. Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning sectionof the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) Wide-range forward accuracy Adjacent error Backward error 0.01 0.5 0 - 25 - 0 5 5 3 0.3 Dimensions Model L (mm) PCN-1A 21.3
$141.77
PEACOCK Peacock Miniature Dial Gauges; 0.01mm, 47 , Range 4mm
Peacock Miniature Dial Gauges; 0.01mm, 47 , Range 4mm Model 47 Graduation 0.01mm Range 4mm Contact point ( X-107 ) Lug back Dial dia. Ø36mm These compact size dial gauges are equipped with small dial faces. They are especially useful for measuring jigs, in restricted areas. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 47 0.01 4 0-50-0 9 - ±13 - ±15 6 5 1.4 Dimensions (mm) Model A B C D E F G H I 47 39.6 20 9.7 36 13 15 3.5 6.5 32
$83.32
PEACOCK Peacock Miniature Dial Gauges; 0.01mm, 36B , Range 3mm
Peacock Miniature Dial Gauges; 0.01mm, 36B , Range 3mm Model 36B Graduation 0.01mm Range 3mm Contact point ( X-107 ) Lug back Dial dia. Ø40.8mm These compact size dial gauges are equipped with small dial faces. They are especially useful for measuring jigs, in restricted areas. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 36B 0.01 3 0-25-50 9 - ±13 - ±15 6 5 1.4 Dimensions (mm) Model A B C D E F G H I 36B 46.2 30.5 12.9 40.8 12.5 19 4 5.1 37
$165.22
PEACOCK Peacock Miniature Dial Gauges; 0.005mm, 36A , Range 3mm
Peacock Miniature Dial Gauges; 0.005mm, 36A , Range 3mm Model 36A Graduation 0.005mm Range 3mm Contact point ( X-107 ) Lug back Dial dia. Ø40.8mm These compact size dial gauges are equipped with small dial faces. They are especially useful for measuring jigs, in restricted areas. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 36A 0.005 3 ±0-25-50 9 - ±13 - ±15 6 5 1.4 Dimensions (mm) Model A B C D E F G H I 36A 46.2 30.5 12.9 40.8 12.5 19 4 5.1 37
$162.19
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 809, Range 80mm
Peacock Long Travel Dial Gauges; 0.01mm, 809, Range 80mm Model 809 Graduation 0.1mm Range 80mm Lug back Stem Ø14mm Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 809 0.1 80 ±0 -5-10 50 - ±100 - ±100 - 35 2.5 Dimensions (mm) Model A B C D E F G H I 809 201.5 86.5 54 112 24 22.5 6 10 108
$566.87
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 507, Range 50mm
Peacock Long Travel Dial Gauges; 0.01mm, 507, Range 50mm Model 507 Graduation 0.01mm Range 50mm Lug back Stem Ø10mm Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 507 0.01 50 ±0 -50-100 15 - ±20 - ±35 9 5 2.5 Dimensions (mm) Model A B C D E F G H I 507 128 81.5 26.7 81.5 17.5 21.5 5.5 8.5 78.5
$256.88
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 307, Range 30mm
Peacock Long Travel Dial Gauges; 0.01mm, 307, Range 30mm Model 307 Graduation 0.01mm Range 30mm Lug back Stem Ø8mm Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 307 0.01 30 ±0 -50-100 14 ±18 ±25 7 5 2.2 Dimensions (mm) Model A B C D E F G H I 307 102 46 22.8 75.5 17.5 21 5 8 72.5
$184.04
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 207S-LL , Spindle lifting lever ,Range 20mm
Peacock Long Travel Dial Gauges; 0.01mm, 207S-LL , Spindle lifting lever ,Range 20mm Model 207S-LL Graduation 0.01mm Range 20mm Spindle lifting lever ( LL-1 ) Small dial face type ( Ø53mm ) Lug back Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 207S-LL 0.01 20 ±0-50-100 10 - ±15 - ±20 7 5 2.0 Dimensions (mm) Model A B C D E F G H I 207S-LL 75 50.5 18.5 53 14.5 20 4 6.5 49
$116.36
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 207S ,Range 20mm,Small dial face type ( Ø53mm )
Peacock Long Travel Dial Gauges; 0.01mm, 207S ,Range 20mm,Small dial face type ( Ø53mm ) Model 207S Graduation 0.01mm Range 20mm Small dial face type ( Ø53mm ) Lug back Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 207S 0.01 20 ±0-50-100 10 - ±15 - ±20 7 5 2.0 Dimensions (mm) Model A B C D E F G H I 207S 75 50.5 18.5 53 14.5 20 4 6.5 49
$83.32
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 0.05mm, and 0.1mm JMAS 2001 , 307S
Peacock Long Travel Dial Gauges; 0.01mm, 0.05mm, and 0.1mm JMAS 2001 , 307S Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model 307S Graduation 0.01mm Range 30mm Small dial face type ( Ø57mm )Contact point ( X-2 )Lug back Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 307S 0.01 30 ±0 -50- 100 14 - ±18 - ±25 7 5 2.2 Dimensions (mm) Model A B C D E F G H I 307S 107 89 22 57 17.5 20 5 7 52
$154.21
PEACOCK Peacock Long Travel Dial Gauges; 0.01mm, 0.05mm, and 0.1mm JMAS 2001 , 207S
Peacock Long Travel Dial Gauges; 0.01mm, 0.05mm, and 0.1mm JMAS 2001 , 207S Dial Gauges are widely used manufacturing plants. ○ The stem, made of SK quench hardened with strength, is malfunction-free due to fastening. ○ The shock-proof mechanism prevents gears from damage due to shocks arisen by abruptly pushing up the spindle. ○ The turning section of the outer frame sealed by the O-ring and the back inside sealed by the packing are waterproof and dust-proof in construction. ○ The back is increased in strength by four screws, and the lug can be turned 90 degrees in the installation way. Model 207S Graduation 0.01mm Range 20mm Small dial face type ( Ø53mm )Lug back Model Graduation (mm) Range (mm) Reading Indication error (µm) Backward error (µm) Repeatability (µm) Measuring force less than (N) Revolution Whole measuring range 1/10 1/2 One Two 207S 0.01 20 ±0 -50- 100 10 - ±15 - ±20 7 5 2.0 Dimensions (mm) Model A B C D E F G H I 207S 75 50.5 18.5 53 14.5 20 4 6.5 49
$83.32
PEACOCK Peacock Linear Gauges Digital Counters, C-700
Peacock Linear Gauges Digital Counters, C-700 Model C-700 User friendliness combined with multi-functinality. Multi-type Equipped with large display functions and various measurement functions, our Digital Counters can be installed in a Control Panel or placed on a desk due to their compact designs Specifications of Digital Counters Model C-500 Displayed digits Selection of 10µm Selection of 1µm Display -9999.99 - 00.00 - 9999.99 -999.999 - 0.000 - 999.999 High-luminance LED display with 7 segments (red) Power supply voltage & power consumption AC100V -- AC240V / 9VA or lower Operating temperature 0 -- +40ºC Compatible Linear Gauges Selection of 10µm display Selection of 1µm display DL-2, D-5, D-10, D-20, D-30, D-50, D-100, DN-10, DN-20, D-5UZ DL-2S, D-5S, D-10S, D-20S, D-30S, D-50S, D-100S DN-10S, DN-20S Accessories AC power cord (2m) ; One cord Metal fittings for panel installation ; Two units ( to be used for installation in panel and securing stand fittings ) Stand fittings ; One unit ( to be used when counter is used as desktop device ) Terminal block functions ( Rear panel ) Terminal block --> Screwless terminal block Usable electric cables --> AWG22 - 28 Length of peeled wire of cables --> 8 - 9mm Pin alignment (*1) St/Sp Controls "START" and "STOP" of MAX, MIN, P-P measurement mode. (*2) React Controls "SUSPEND" and "START" of P-P measurement mode. 3 Latch Controls "LATCH" and "CANCEL" of measured value. 4 Reset External "RESET" "PRESET" ( Function available only in Model No. C-700 ) 5 Alarm Error signal output Max Min P-P Display Display Display (*6) -NG Outputs -NG based on --> +NG(2) -NG(1) NG(2) OK±NG judgment (red LED). (*7) OK Outputs OK based on --> OK OK OK OK±NG judgment (green LED). (*8) +NG Outputs +NG based on --> +NG(1) -NG(2) NG(1) OK±NG judgment (orange LED). (1) : NG output in first stage(2) : NG output in second stage 9 GND GND (* ) Circled numbers indicate functions available only in Model No. C-700 Dip sw setting functions ( Printed circuit board ) Dip(1) Dip(2) SW 1 Select 1µm or 10µm SW 1 Settings by Manufacturer SW 2 Select direction of counting SW 2 Select whether or not to include default values for OK±NG judgment SW 3 Select activation or non-activation of error output. SW 3 Select either "orthogonal" or "sine" for input waveform. SW 4 Select activation or non- activation of overflow. SW 4 Select either 400msec or 100msec for RESET time. Data output (RS-232C) D-Sub9P plug INCH screw Pin Alignment 1 NC -- Communication mode ; Half-duplexasynchronouscommunication 2 Rxd in <-- Communication speed ; 9600bps 3 Txd --> out Format ; 7Bit ASCI I 4 NC -- Parity ; even number 5 SG -- Stop bit ; 1Bit 6 NC -- RTS / CTS ; Returned when not in use. 7 RTS --> out Reception command ; Transmission request ASCI I [T] [t] 8 CTS in <-- ; Reset ASCI I [R] [r] 9 NC -- Connection cables ; Cross cables ( not included ) Options Excel input software :PK-2002 ; Data imported into Excel cells from RS-232C output. BCD output board : CB-BCD ; Cannot be used in combination with RS-232C output. Display functions 1/1 display --> Displays the measured value as is. 1/2 display --> Displays the measured value after halving it. ×2 display --> Displays the measured value after doubling it. Note ; With 1µm display and ×2 display, the lowest digit will be displayed as an even number Presetting display function Can display preset values Measurement mode function Current value display Maximum value (Max) RESET action is taken by ST of the ST/SP control terminal. Minimum value (Min) Deflection (P-P) OK±NG judgment function Current value mode +NG OK -NG Maximum value mode OK +NG (1) +NG (2) Minimum value mode OK -NG (1) -NG (2) Deflection mode OK NG (1) NG (2) Dimensions/ Weight 144(W)×72(H)×160(D)mm / 950g
$1,852.84
PEACOCK Peacock Linear Gauges Digital Counters, C-500
Peacock Linear Gauges Digital Counters, C-500 Model C-500 Priority on user friendliness. Simple type Equipped with large display functions and various measurement functions, our Digital Counters can be installed in a Control Panel or placed on a desk due to their compact designs Specifications of Digital Counters Model C-500 Displayed digits Selection of 10µm Selection of 1µm Display -9999.99 - 00.00 - 9999.99 -999.999 - 0.000 - 999.999 High-luminance LED display with 7 segments (red) Power supply voltage & power consumption AC100V -- AC240V / 9VA or lower Operating temperature 0 -- +40ºC Compatible Linear Gauges Selection of 10µm display Selection of 1µm display DL-2, D-5, D-10, D-20, D-30, D-50, D-100, DN-10, DN-20, D-5UZ DL-2S, D-5S, D-10S, D-20S, D-30S, D-50S, D-100S DN-10S, DN-20S Accessories AC power cord (2m) ; One cord Metal fittings for panel installation ; Two units ( to be used for installation in panel and securing stand fittings ) Stand fittings ; One unit ( to be used when counter is used as desktop device ) Terminal block functions ( Rear panel ) Terminal block --> Screwless terminal block Usable electric cables --> AWG22 - 28 Length of peeled wire of cables --> 8 - 9mm Pin alignment (*1) St/Sp Controls "START" and "STOP" of MAX, MIN, P-P measurement mode. (*2) React Controls "SUSPEND" and "START" of P-P measurement mode. 3 Latch Controls "LATCH" and "CANCEL" of measured value. 4 Reset External "RESET" "PRESET" ( Function available only in Model No. C-700 ) 5 Alarm Error signal output Max Min P-P Display Display Display (*6) -NG Outputs -NG based on --> +NG(2) -NG(1) NG(2) OK±NG judgment (red LED). (*7) OK Outputs OK based on --> OK OK OK OK±NG judgment (green LED). (*8) +NG Outputs +NG based on --> +NG(1) -NG(2) NG(1) OK±NG judgment (orange LED). (1) : NG output in first stage(2) : NG output in second stage 9 GND GND (* ) Circled numbers indicate functions available only in Model No. C-700 Dip sw setting functions ( Printed circuit board ) Dip(1) Dip(2) SW 1 Select 1µm or 10µm SW 1 Settings by Manufacturer SW 2 Select direction of counting SW 2 Select whether or not to include default values for OK±NG judgment SW 3 Select activation or non-activation of error output. SW 3 Select either "orthogonal" or "sine" for input waveform. SW 4 Select activation or non- activation of overflow. SW 4 Select either 400msec or 100msec for RESET time. Data output (RS-232C) D-Sub9P plug INCH screw Pin Alignment 1 NC -- Communication mode ; Half-duplexasynchronouscommunication 2 Rxd in <-- Communication speed ; 9600bps 3 Txd --> out Format ; 7Bit ASCI I 4 NC -- Parity ; even number 5 SG -- Stop bit ; 1Bit 6 NC -- RTS / CTS ; Returned when not in use. 7 RTS --> out Reception command ; Transmission request ASCI I [T] [t] 8 CTS in <-- ; Reset ASCI I [R] [r] 9 NC -- Connection cables ; Cross cables ( not included ) Options Excel input software :PK-2002 ; Data imported into Excel cells from RS-232C output. BCD output board : CB-BCD ; Cannot be used in combination with RS-232C output. Display functions 1/1 display --> Displays the measured value as is. 1/2 display --> Displays the measured value after halving it. ×2 display --> Displays the measured value after doubling it. Note ; With 1µm display and ×2 display, the lowest digit will be displayed as an even number Presetting display function Zero setting only Measurement mode function --- OK±NG judgment function --- Dimensions/ Weight 144(W)×72(H)×160(D)mm / 950g
$1,763.26
PEACOCK Peacock Linear Gauges ; Measurement range 0 - 50mm , D-50S
Peacock Linear Gauges ; Measurement range 0 - 50mm , D-50S Model D-50S Resolution 0.001mm Range 0 - 50mm With very sturdy ø 20mm stem. Ultra-high precision achievable with exclusive gauge stand (PDS-2) Specifications Model D-50S Range 50mm Resolution 0.001mm Accuracy (excluding quantized error) 0.004mm Measuring force Less than 3.0N Cable length 2m Mounting method ø 20mm stem or fastening by M4 screws at two positions Contact point M2.5 × 0.45 Sø 2.4mm steel Operating temperature 0 - 40ºC Weight 450g Output signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Compatible standard counters C-500 / C-700 / CM-5B Accessories Finger lever for lifting spindle ---> 1 pc Featuares If Spindle inner spring is removed, measuring force will be that of spindle itself (only when in upright position) D-50 , D-50S ---> 1.0N D-100 , D-100S ---> 1.1N Recommended stand is PDS-2 Option Level mounting clamp ( GB-50 ) Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted.
$1,101.04
PEACOCK Peacock Linear Gauges ; Measurement range 0 - 50mm , D-50
Peacock Linear Gauges ; Measurement range 0 - 50mm , D-50 Model D-50 Resolution 0.01mm Range 0 - 50mm With very sturdy ø 20mm stem. Ultra-high precision achievable with exclusive gauge stand (PDS-2) Specifications Model D-50 Range 50mm Resolution 0.01mm Accuracy (excluding quantized error) 0.01mm Measuring force Less than 3.0N Cable length 2m Mounting method ø 20mm stem or fastening by M4 screws at two positions Contact point M2.5 × 0.45 Sø 2.4mm steel Operating temperature 0 - 40ºC Weight 450g Output signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Compatible standard counters C-500 / C-700 / CM-5B Accessories Finger lever for lifting spindle ---> 1 pc Featuares If Spindle inner spring is removed, measuring force will be that of spindle itself (only when in upright position) D-50 , D-50S ---> 1.0N D-100 , D-100S ---> 1.1N Recommended stand is PDS-2 Option Level mounting clamp ( GB-50 ) Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted.
$1,033.19
PEACOCK Peacock Linear Gauges ; Measurement range 0 - 100mm , D-100S
Peacock Linear Gauges ; Measurement range 0 - 100mm , D-100S Model D-100S Resolution 0.001mm Range 0 - 100mm With very sturdy ø 20mm stem. Ultra-high precision achievable with exclusive gauge stand (PDS-2) Specifications Model D-100S Range 100mm Resolution 0.001mm Accuracy (excluding quantized error) 0.005mm Measuring force Less than 3.5N Cable length 2m Mounting method ø 20mm stem or fastening by M4 screws at two positions Contact point M2.5 × 0.45 Sø 2.4mm steel Operating temperature 0 - 40ºC Weight 520g Output signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Compatible standard counters C-500 / C-700 / CM-5B Accessories Finger lever for lifting spindle ---> 1 pc Featuares If Spindle inner spring is removed, measuring force will be that of spindle itself (only when in upright position) D-50 , D-50S ---> 1.0N D-100 , D-100S ---> 1.1N Recommended stand is PDS-2 Option Level mounting clamp ( GB-50 ) Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted.
$1,415.30
PEACOCK Peacock Linear Gauges ; Measurement range 0 - 100mm , D-100
Peacock Linear Gauges ; Measurement range 0 - 100mm , D-100 Model D-100 Resolution 0.01mm Range 0 - 100mm With very sturdy ø 20mm stem. Ultra-high precision achievable with exclusive gauge stand (PDS-2) Specifications Model D-100 Range 100mm Resolution 0.01mm Accuracy (excluding quantized error) 0.01mm Measuring force Less than 3.5N Cable length 2m Mounting method ø 20mm stem or fastening by M4 screws at two positions Contact point M2.5 × 0.45 Sø 2.4mm steel Operating temperature 0 - 40ºC Weight 520g Output signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Compatible standard counters C-500 / C-700 / CM-5B Accessories Finger lever for lifting spindle ---> 1 pc Featuares If Spindle inner spring is removed, measuring force will be that of spindle itself (only when in upright position) D-50 , D-50S ---> 1.0N D-100 , D-100S ---> 1.1N Recommended stand is PDS-2 Option Level mounting clamp ( GB-50 ) Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted.
$1,258.27
PEACOCK Peacock Linear Gauges ; Measurement range ( 0 - 5mm ),D-5S Pencil Type
Peacock Linear Gauges ; Measurement range ( 0 - 5mm ),D-5S Pencil Type Pencil Type D-5S Resolution 0.001mm Range 0~5mm Best suited for confined conditions. (D-5/D-5S) Specifications Model D-5S Range 5mm Resolution 0.001mm Accuracy (excluding quantized error) 0.002mm Measuring force Less than 0.5N Mounting method ø 8mm stem Contact point Sø 2.4mm cooper (X-2) Cord length 2m Operating temperature 0 - 40ºC Output signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Compatible standard Options C-500 / C-700 CM-5B Options Extension cables of 2, 3, 5, and 10 meters are available (*1) Lever moves linearly, unlike the arc movement in a lever type dial indicator. (*2) Largest deviation value if narrow range for every 0.5mm step.
$718.04
PEACOCK Peacock Linear Gauges ; Measurement range ( 0 - 5mm ),D-5 Pencil Type
Peacock Linear Gauges ; Measurement range ( 0 - 5mm ),D-5 Pencil Type Pencil Type D-5 Resolution 0.01mm Range 0~5mm Best suited for confined conditions. (D-5/D-5S) Specifications Model D-5 Range 5mm Resolution 0.01mm Accuracy (excluding quantized error) 0.005mm Measuring force Less than 0.5N Mounting method ø 8mm stem Contact point Sø 2.4mm cooper (X-2) Cord length 2m Operating temperature 0 - 40ºC Output signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Compatible standard Options C-500 / C-700 CM-5B Options Extension cables of 2, 3, 5, and 10 meters are available (*1) Lever moves linearly, unlike the arc movement in a lever type dial indicator. (*2) Largest deviation value if narrow range for every 0.5mm step.
$603.12
PEACOCK Peacock Linear Gauges ; 20mm range,D-20
Peacock Linear Gauges ; 20mm range,D-20 Measurement range (0 - 20mm) 10mm and 20mm measurement ranges are the easiest to use. Used in conjunction with digital counters, these gauges can be set up in places where dial gauges are now being used. Set the gauge by either stem or lug back. For lifting spindle, both lever and release types are available. Rectangular wave output typ (DN-10/DN-10S/DN-20/DN-20S) For use in electrically noisy environments. For applications requiring extra long cables. (10 to 50 meters are available) Specifications Model D-20 Range 20mm Resolution 0.01mm Accuracy (excluding quantized error) 0.005mm Measuring force Less than 1.5N Cable length 2m Mounting method Ø8mm stem or 6.5mm hole on lug back Contact point M2.5 × 0.45 SØ2.4mm steel (X-2) Operating temperature 0 - 40ºC Weight 300g Output Signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Rectangular wave (L=0v H=5v) Compatible standard counters C-500 / C-700 CM-5B (*except DN-10S, DN-20S) Options * Release (RE-4) Lifting lever (LL-1) * Release (RE-4) * Dust proof rubber (BG-10) * Flat back (GB3-D20) * Flat back (GB3-D1O) , screws (S-110) * Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted. * Features DN-10 DN-10S DN-20 DN-20S 1. Recommended for locations where cable extension (10 to 50 meters) is necessary. 2. Recommended for use in electrically noisy environments. Notes of wiring : A signal wire should be duct wiring apart from other Power lines.
$629.04
PEACOCK Peacock Linear Gauges ; 10mm range,D-10S
Peacock Linear Gauges ; 10mm range,D-10S Measurement range (0 - 20mm) 10mm and 20mm measurement ranges are the easiest to use. Used in conjunction with digital counters, these gauges can be set up in places where dial gauges are now being used. Set the gauge by either stem or lug back. For lifting spindle, both lever and release types are available. Rectangular wave output typ (DN-10/DN-10S/DN-20/DN-20S) For use in electrically noisy environments. For applications requiring extra long cables. (10 to 50 meters are available) Specifications Model D-10S Range 10mm Resolution 0.001mm Accuracy (excluding quantized error) 0.002mm Measuring force Less than 1.0N Cable length 2m Mounting method Ø8mm stem or 6.5mm hole on lug back Contact point M2.5 × 0.45 SØ2.4mm steel (X-2) Operating temperature 0 - 40ºC Weight 220g Output Signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Rectangular wave (L=0v H=5v) Compatible standard counters C-500 / C-700 CM-5B (*except DN-10S, DN-20S) Options * Release (RE-4) Lifting lever (LL-1) * Release (RE-4) * Dust proof rubber (BG-10) * Flat back (GB3-D20) * Flat back (GB3-D1O) , screws (S-110) * Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted. * Features DN-10 DN-10S DN-20 DN-20S 1. Recommended for locations where cable extension (10 to 50 meters) is necessary. 2. Recommended for use in electrically noisy environments. Notes of wiring : A signal wire should be duct wiring apart from other Power lines.
$629.04
PEACOCK Peacock Linear Gauges ; 10mm range,D-10
Peacock Linear Gauges ; 10mm range,D-10 Measurement range (0 - 20mm) 10mm and 20mm measurement ranges are the easiest to use. Used in conjunction with digital counters, these gauges can be set up in places where dial gauges are now being used. Set the gauge by either stem or lug back. For lifting spindle, both lever and release types are available. Rectangular wave output typ (DN-10/DN-10S/DN-20/DN-20S) For use in electrically noisy environments. For applications requiring extra long cables. (10 to 50 meters are available) Specifications Model D-10 Range 10mm Resolution 0.01mm Accuracy (excluding quantized error) 0.005mm Measuring force Less than 1.0N Cable length 2m Mounting method Ø8mm stem or 6.5mm hole on lug back Contact point M2.5 × 0.45 SØ2.4mm steel (X-2) Operating temperature 0 - 40ºC Weight 220g Output Signal 90º phase difference, 20µm pitch (R03-PB8M Tajimi connector) Rectangular wave (L=0v H=5v) Compatible standard counters C-500 / C-700 CM-5B (*except DN-10S, DN-20S) Options * Release (RE-4) Lifting lever (LL-1) * Release (RE-4) * Dust proof rubber (BG-10) * Flat back (GB3-D20) * Flat back (GB3-D1O) , screws (S-110) * Customer must specify if application is up-side-down. The measuring force changes when the gauge is inverted. * Features DN-10 DN-10S DN-20 DN-20S 1. Recommended for locations where cable extension (10 to 50 meters) is necessary. 2. Recommended for use in electrically noisy environments. Notes of wiring : A signal wire should be duct wiring apart from other Power lines.
$578.95
PEACOCK Peacock Lever Type Dial Indicators PIC TEST ; Change lever type, PC-3L Parallel
Peacock Lever Type Dial Indicators PIC TEST ; Change lever type, PC-3L Parallel Model PC-3L Graduation 0.01mm Range 1.0mm Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning section of the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.01 1.0 0 - 50 - 0 10 5 4 0.4 43.0
$258.12
PEACOCK Peacock Lever Type Dial Indicators PIC TEST ; Change lever type, PC-3 Parallel
Peacock Lever Type Dial Indicators PIC TEST ; Change lever type, PC-3 Parallel Model PC-3 Graduation 0.01mm Range 0.5mm Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning section of the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.01 0.5 0 - 25 - 0 5 5 3 0.4 21.4
$147.97
PEACOCK Peacock Lever Type Dial Indicators PIC TEST ; Change lever type, PC-1L,Long contact point
Peacock Lever Type Dial Indicators PIC TEST ; Change lever type, PC-1L,Long contact point Model PC-1L Graduation 0.01mm Range 1.0mm Long contact point (L = 43.0mm) Miniature Bearing Used The miniature bearing used as a bearing at the pivot of the contact point to show good indication stability without any effect by rod play. O-ring used Oil resistance is enhanced by seating the O-ring in the turning section of the outer frame. Graduation (mm) Range (mm) Reading Accuracy (µm) Measuring force less than (N) L (mm) Wide-range forward accuracy Adjacent error Backward error 0.01 1.0 0 - 50 - 0 10 5 4 0.4 43.0
$145.49
PEACOCK Peacock LB-9 Inside Dial Caliper Gauge (Throat depth: 130mm)
Peacock LB-9 Inside Dial Caliper Gauge (Throat depth: 130mm) Dial Calipers LB series (Inside measuring of ID and groove widths) Model LB-9 Graduation 0.01mm Range 20 - 40mm Throat depth 130mm Specifications Model Graduation (mm) Range (mm) Indication error (mm) Throat depth (mm) Height of contact point (mm) LB-9 0.01 20~40 ±0.03 130 2 (SK hardened, one unit with frame)
$633.66
PEACOCK Peacock LB-1 Inside Dial Caliper Gauge (Throat depth: 125mm)
Peacock LB-1 Inside Dial Caliper Gauge (Throat depth: 125mm) Dial Calipers LB series (Inside measuring of ID and groove widths) Model LB-1 Graduation 0.1mm Range 10 - 90mm Throat depth 125mm Specifications Model Graduation (mm) Range (mm) Indication error (mm) Throat depth (mm) Height of contact point (mm) LB-1 0.1 10 - 90 ±0.2 125 2
$563.84
PEACOCK Peacock LA-9 Outside Dial Caliper Gauge (Throat depth: 100mm)
Peacock LA-9 Outside Dial Caliper Gauge (Throat depth: 100mm) The dial caliper gauge show its great power in measurement of inside and outside sizes, wall thickness, groove width and hole diameters and any other shapes and sections that is not apparently accessible Model LA-9 Graduation 0.1mm Range 0 - 30mm Throat depth 100mm Specifications Model Graduation (mm) Range (mm) Indication error (mm) Throat depth (mm) Dimensions (mm) H 1 H 2 H 3 H 4 LA-9 0.1 0~30 ±0.2 100 2 12 2 12
$649.64
PEACOCK Peacock LA-6 Outside Dial Caliper Gauge (Throat depth: 60mm)
Peacock LA-6 Outside Dial Caliper Gauge (Throat depth: 60mm) The dial caliper gauge show its great power in measurement of inside and outside sizes, wall thickness, groove width and hole diameters and any other shapes and sections that is not apparently accessible Model LA-6 Graduation 0.01mm Range 0 - 10mm Throat depth 60mm Specifications Model Graduation (mm) Range (mm) Indication error (mm) Throat depth (mm) Dimensions (mm) H 1 H 2 H 3 H 4 LA-6 0.01 0~10 ±0.03 60 2.5 18 2.5 18
$624.07